Verified by manufacturer 9 days ago
Industrial sectional folding door.
Recommended for factories, warehouses, garages.
A double-skinned thermally insulated steel panelled door designed for reducing building energy consumption.
Finish | Galvanized |
Material | Steel |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/60 Doors L20/530 Sliding folding external doors |
Track system | Heavy duty horizontal track system. |
Door leaf | |
Construction | Steel insulated panels 1000 x 50 mm. 50 mm insulated CFC-free rigid polyurethane foam, density 40 kg/m³. Panels have a U value of 0.9 W/m²k and are completed with pre drilled galvanised steel end caps. EPDM 2 mm thick weather proof seals to top and side reveals.Guidance for specification option: Panels can be solid or include vision panels (Maximum of one vision panel per linear metre width up to a maximum of two per panel). |
Finish | All components fully galvanized with galvanized fixings. Horizontal 5mm tracks with heavy duty fixing angles. EPDM 2 mm thick Side Seals. |
Operation | Push/pull open and close.BS EN 12453 Fortress Drive System™ 415 Volt 3-phase or 1ph operator with push button controls, supplied with manual release cable device for use in the event of emergency open/closure. |
Hardware | Doors supplied with adjustable side hinges complete with carriers, intermediate hinges, nylon and steel rollers. |
Accessories | Auto time return control panel.Induction loop card.Keyed shoot bolts.Micro switch.Photocell.Guidance for specification option: Light beam sensor will detect the presence of a person or object that interrupts the light beam providing a non-contact safety system. Radar sensor.Remote control receiver and transmitters.Self-checking safety edge.Guidance for specification option: Will stop and reverse the door movement immediately upon contact with an obstacle. Spring load locking shoot bolts.Wicket gate.Guidance for specification option: Standard size 800 x 2000 mm, complete with lock, handles and safety locking system. |
Controls | BS EN 12453 Hold-to-run and dead-man close automation for applications where there are untrained door users. |
Glazed vision panels | None. Fully glazed panoramic window panels. Guidance for specification option: 480w x 862h double glazed argon filled units., |
Standards | EN 12425, BS EN 12604, BS EN 12453, BS EN 12424 |
Acoustic performance | Weighted Level Difference Dw value 18 dB. |
Thermal performance | Insulated panel material U Value 0.9 w/m²K. |
Size: | Manufacturer guidanceMaximum recommended dimensions up to 7500 x 6000 mm. Larger sizes by specification. Please consult Fortress SEFA for advice. |
Material | Steel |