Verified by manufacturer 2 months ago
100 mm thickness
Polyisocyanurate insulation flat roof boards.
Flat roofs: Above metal, concrete and timber decks.
Polyisocyanurate (PIR) foam insulation board for flat roofs, suitable for use in new build and refurbishment projects where the warm flat roof is covered with a hot or cold bonded, built-up bituminous waterproofing system.
Features and benefits:
Color | White Guidance for specification option: Creamy white tissue. Yellow Guidance for specification option: Core. Grey |
Finish | Sandblasted |
Material | Polyisocyanurate (PIR) Foil |
Shape | Rectangle |
Length | 1200 mm |
Width | 600 mm |
Height | 30 mm 50 mm 70 mm 80 mm 100 mm |
Warranty description | Lifetime |
Uniclass | |
CAWS | J41/10 Reinforced bitumen membrane warm deck roof covering J41/430 Warm deck roof insulation |
Standard | To BS EN 13165, BS EN 1604, BS 476-7: Class 1 and BS EN 13501-1. |
Fire performance | F.Guidance for specification option: To BS EN 13501-1: Euroclass F. |
Cross section | Uniform thickness. |
Thickness (nominal) | 100 mm. |
Face size (length x width) | 1200 x 600 mm. |
Compressive strength at 10% deformation | >150 kPa. |
Facing | Bitumen membrane.Guidance for specification option: Fleece-finished, bitumen facing on one side. Glass tissue.Guidance for specification option: Mineral coated perforated glass tissue facing on one side. |
Edges | Butt. |
Vapour resistivity | 300 MNs/g. Guidance for specification option: Approximate core water vapour resistivity. |
Dimensional stability | DS (TH) 4. Guidance for specification option: To BS EN 1604. |
ThermalConductivity | 0.025 W/mK. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 5 | |
- | 5 |