NBS Source
I'm a manufacturer
Compare variants

Low Temperature High Capacity R-Split Heat Pump (Size 11-14-16) - Water heater

Verified by manufacturer 3 months ago

EBBH11D6V + ERLA11DV3

Daikin Ltd Variant:

Low temperature, high capacity R-Split heat pump.

Jump to:
+44 (0)845 641 9000 Website

Application

For use in domestic applications.


The indoor units can be installed in many different places including garages, basements, utility rooms and kitchens, while blending in with the indoor design.


Description

An outdoor, high capacity, refrigerant split unit combined with an indoor wall mounted or floor standing air-to-water heat pump. It provides cooling next to heating and domestic hot water.


Features both an indoor and outdoor unit.

Features two indoor variants i.e. wall mounted and floor standing with 230L water tank.


Features and benefits:

  • Easy installation.
  • R-32 Bluevolution technology reduces environmental impact due to its high energy efficiency and low refrigerant charge.
  • Leaving water temperature of 60C down to -7C outdoor.
  • W-LAN module and cartridge compatible.
  • PCB board and hydraulic components are located in the front for easy access.
  • Small installation footprint, similar to other household appliances.
  • Suitable for small installation spaces.
  • Black grille to hide the fan from view.


For full technical information, consult manufacturer's literature.


Components:

  • ERLA11-16DV3 - Outdoor unit that extracts heat from the outdoor air.
  • EBBH-D6V/9W - Wall-mounted heating only air to water heat pump.
  • EBBX-D6V/9W - Wall-mounted reversible air-to-water heat pump.
  • EBVH16SU23D6V - Floor standing air to water heat pump for heating and hot water.


General information

Color

White

Black

Manufacturer guidance

  • Ivory white case material (ERLA11-16DV3).
  • White and black casing (EBBH-D6V/9W, EBBX-D6V/9W and EBHV-D6V/9W).


Material

Steel

Guidance for specification option:

Polyester painted galvanised steel plate (ERLA11-16DV3).

Resin

Guidance for specification option:

Resin sheet material (EBBH-D6V/9W, EBBX-D6V/9W and EBHV-D6V/9W).

Shape

Rectangle

Length

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Width

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Height

-

Manufacturer guidance

Dependent on unit specified, see specification data for details.

Warranty description

Five year

Uniclass

Pr_70_60_37_04 Air-to-water heat pumpsPrimary

CAWS

T90/505 Air-to-water heat pumps

T90/505 Air-to-water heat pumps

Specification data - Air-to-water heat pumps

Heat pump type

Split.

Mode

Heating.

Coefficient of performance (minimum)

4.83 kW (condition 1); 3.66 kW (condition 2).

Guidance for specification option:

  • Condition 1: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).
  • Condition 2: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C).

Output

-

Heating

10.6 kW (condition 1); 9.82 kW (condition 2).

Guidance for specification option:

  • Condition 1: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).
  • Condition 2: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C).

Fan

-

Type

Propellar.

Configuration

Horizontal.

Compressor

-

Type

Swing.

Sealing

Hermetically sealed.

Drive

Inverter driven.

Accessories

Not required.

Stainless steel tank.

ECH2O thermal store.

Refrigerant

R32.

Guidance for specification option:

  • GWP: 675.0.
  • Charge: 3.08 kg.
  • Control: Electronic expansion valve.
  • Refrigerant oil type: FW68DA.

Unit dimensions

870 x 1100 x 460 mm (ERLA11DV3); 840 x 440 x 390 mm (EBBH11D6V).

Manufacturer guidance

Height x width x depth.

Unit weight

101 kg (ERLA11DV3); 52.5 kg (EBBH11D6V).

Safety devices

High pressure switch, low pressure switch, fan driver overload protector, fuse and compressor motor thermal protector.

HeatingWaterFlowRate

29.3 L/m (condition 1); 28.7 L/min (condition 2).

Guidance for specification option:

  • Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C).
  • Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C).

Manufacturer guidance

Water side heat exchanger water flow rate.

Sound

To EN14825, 62.0 dB(A) (outdoor); 44.0 dB(A) (indoor).

Guidance for specification option:

Indoor - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.

Manufacturer guidance

Sound power level.

Air flow

3350 m³/h.

Manufacturer guidance

Air to water unit rated airflow (outdoor).

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Similar products from Daikin Ltd

Daikin Altherma High Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 14-16-18) - Heating system

Daikin Altherma High Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 14-16-18) - Heating system

Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system

Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system

Daikin Altherma Low Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 8-10-12) - Heating system

Daikin Altherma Low Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 8-10-12) - Heating system

Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump

Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump

Low Temperature Low Capacity R-Split Heat Pump (Size 4-6-8) - Heating system

Low Temperature Low Capacity R-Split Heat Pump (Size 4-6-8) - Heating system