Verified by manufacturer 21 days ago
IsoTec micro framed leaf in door frame, single leaf, single action.
Single glazed partition system with a 54 mm wide frame and with extruded LOFT transoms and/ or mullions.
All sectors: Commercial: Education; Healthcare; MoD; Airport; Rail; Industrial; Hospitality; Residential; Public.
Consult manufacturer for further details.
Single glazed partition system with a 54 mm wide frame and with extruded LOFT transoms and/ or mullions.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Silver Other |
Finish | Polished Anodized Guidance for specification option: Etched and anodized. Powder-coated |
Material | Aluminium Guidance for specification option: 6063 T6. Glass |
Shape | Rectangle Other Manufacturer guidanceTo suit project requirements; consult manufacturer for further details. |
Length | Bespoke |
Width | 54 mm |
Height | Bespoke |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third-party certification | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 54 mm. |
Partition height (nominal) | Manufacturer guidanceInsert requirements. For partitions over 3000 mm high, consult with manufacturer. |
Width (nominal) | Manufacturer guidanceInsert requirements. For partitions over 1200 mm wide, consult with manufacturer. |
Deflection allowance (maximum) | |
Head | No deflection; 27 mm deep x 54 mm wide channel.No deflection; 50 mm deep x 54 mm wide channel.±15 mm deflection; 80 mm deep x 74 mm wide channel.±25 mm deflection; 90 mm deep x 74 mm wide channel. |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | 27 mm deep x 54 mm wide channel.50 mm deep x 54 mm wide channel. |
Panel partition type | Framed glass - single offset glazed - with extruded LOFT transoms and/ or mullion profiles. |
Framing, fixing points and joints | 27 mm deep x 54 mm wide channel.50 mm deep x 54 mm wide channel.Manufacturer guidanceMullions, transoms and corners: Extruded LOFT trims. |
Solid panels | |
Type | Not required.Back painted glass.Steel faced boards.Veneered panels.Magnetic white board film. |
Finish and colour | Not applicable.To match frame.Polyester powder-coated, RAL.Guidance for specification option: Insert colour requirement. Polished and chemically brightened.Linished and chemically brightened.Etched and anodized.Guidance for specification option: Insert requirement. |
Joint treatment | |
Type | Mullion, transom: 27 mm deep x 54 mm wide extruded profile; Corners: 54 x 54 mm corner box with abutment tracks. |
Finish and colour | RAL.Guidance for specification option: Insert colour and gloss level. Anodized.Guidance for specification option: Insert colour reference. |
Glazed panels | |
Type | Single offset glazed, 12–15 mm annealed laminate.Single offset glazed, 12–15 mm annealed acoustic laminate.Single offset glazed, 12–15 mm toughened - heat soaked.Single offset glazed, 12–15 mm LCD switchable.Single offset glazed, 12–15 mm patterned, fluted.Single offset glazed, 12–15 mm low iron.Guidance for specification option: All glass types available; consult manufacturer and insert requirements. |
Integral blinds | n/a.Guidance for specification option: Not suitable for this system. |
Additional features | None.Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics. |
Door arrangement | |
Type | IsoTec micro framed leaf in door frame, single leaf, single action. |
Door frames | Planet A188 aluminium door frame, with single leaf set. |
Door panels | |
Type | Planet IsoTec 12 mm door leaf – non-acoustic.Planet IsoTec 12 mm door leaf – 34 dB Rw.Planet IsoPro, single glazed metal framed door leaf – 34 dB Rw.Planet IsoPro, double glazed metal framed door leaf – 34 dB Rw.Planet IsoPro, single glazed metal framed door leaf – 36 dB Rw.Planet IsoPro, double glazed metal framed door leaf – 39 dB Rw.Planet IsoPro, double glazed metal framed door leaf – 42 dB Rw.Timber 44 mm leaf on hinges – 29 dB on to carpet.Timber 44 mm leaf on hinges – 32 dB on to carpet.Timber 54 mm rebated leaf on hinges – 33 dB on to carpet.Timber 54 mm rebated leaf on hinges – 38 dB on to solid floor.Timber 54 mm rebated leaf on hinges – 40 dB on to aluminium threshold. |
Vision panels | Not required.Required.Guidance for specification option: Available with timber door leaves only; consult manufacturer for details and insert requirements. |
Ceiling | |
Type | Manufacturer guidanceConsult manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | 27 mm deep x 54 mm wide channel. |
Trims | Mullion, transom: 27 mm deep x 54 mm wide extruded profile. |
Hardware | Manufacturer guidanceSee appropriate door specification for applicable ironmongery options. |
Seals | Clear perimeter compression seals.Black perimeter compression seals. |
Cable management and outlets | Not required.As Glazed panels - Additional features.Guidance for specification option: Double glazed/ boarded Tech Panel to incorporate room booking systems, access control and other electronics. |
Other features | Manufacturer guidanceConsult manufacturer and insert requirements or leave blank. |
Product Reference | LOFT54 Offset Single Glazed Panel Partition System (True) |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | 35 dB Rw. 36 dB Rw. 37 dB Rw. 38 dB Rw. 39 dB Rw. Manufacturer guidanceTo comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing options subject to further design development. |
Partition | Framed glass - single offset glazed - with extruded LOFT transoms and/or mullions. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | 27 mm deep x 54 mm wide extruded LOFT mullion and/ or transom. |
System accessories | Manufacturer guidanceTech panels, access control - consult with manufacturer for details. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Finish/ Colour | Polyester powder-coated, RAL. Guidance for specification option: Insert colour requirement. Polished and chemically brightened. Linished and chemically brightened. Etched and anodized. Guidance for specification option: Insert requirement. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Guidance for specification option: 6063 T6. Glass |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 71.2 kg CO₂ eq/m² Self declared Guidance for specification option: There will be slight variances in embodied carbon if different glass thicknesses, etc, are used. These embodied carbon figures are for 1 m² of each type of partition – modules A1-A3 including biogenic carbon. The EPD for the single glazed partition systems is based on powder-coated aluminium-framed single-glazed partition systems using 12.8 mm laminated glass, without a door. |
Recyclability | 100% Guidance for specification option: Aluminium and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% for glass. 70% for aluminium. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
FireClear100 Double Glazed Fire Rated Partition System
FireClear20 Single Glazed Fire Rated Partition System
FireClear54 Double Glazed Fire Rated Partition System
FireEco Ei30 Double Glazed Fire Rated Partition System
FireEco Ei30 Single Glazed Fire Rated Partition System
FireEco Ei60 Double Glazed Fire Rated Partition System
FireEco Ei60 Single Glazed Fire Rated Partition System
FirePro E120 Single Glazed Partition System And Ei 60 Doorset
FirePro E30 Double Glazed Partition System And Doorset
FirePro E30 Single Glazed Partition System and Doorset