NBS Source
I'm a manufacturer
Compare variants

LoadTracker XRGI® CHP - Combined Heat and Power (CHP) Units

Verified by manufacturer 5 days ago

XRGI®6 without condensing technology

SAV Systems Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

Modulating combined heat and power (CHP) units.

Jump to:
+44 01483 771 910 Website

Application

Suitable for communal heating systems and commercial buildings with simultaneous heat and electricity demand.

Description

The XRGI® is a combined heat and power plant (CHP) that works on the principle of co-generation. In addition, it can also be extended with thermal storage to optimise operation.


High efficiency CHP unit with maximum rating of 20 kW(e)/ 40 kW(th). Can modulate down to 50% load.


Features and benefits:

  • Power unit, comprising gas-fired engine and generator. 
  • Heat distributor assembly, for ease of interfacing with building heating systems. 
  • Control panel, for matching of generated output with electrical demand. 
  • Thermal storage vessel, for absorbing thermal mismatch between supply and demand.
  • Matching capability produces long running times.
  • Design stage support offered with assessments of CHP potential.
  • Commissioning and help with G98/G99 applications also included. 
  • Stand-alone system with BMS connectivity.
  • Used in hybrid energy centres.
  • On-demand, low-cost electricity for heat pumps.

General information

Color

Blue

Finish

Painted

Shape

Rectangle

Length

930 mm

1120 mm

Width

640 mm

750 mm

Height

960 mm

1170 mm

Warranty description

Two year

Uniclass

Pr_60_70_65_60 Packaged combined heat and power (CHP) unitsPrimary

CAWS

T90/110 Heating system

Specification data - Packaged combined heat and power (CHP) units

Prime mover

-

Standard

To EN 50465.

Engine type

Gas engine.

Electrical generator

-

Standard

To ISO 8528-13:2016.

Type

Asynchronous.

Operation

Three phase, 400 V, 50 Hz.

Output

-

Electrical power

6.0 kW.

Thermal power

12.4 kW.

Efficiency

-

Electrical

30.1%.

Thermal

62.3%.

Overall

92.4%.

Components

Power Unit, iQ20s Control Panel, Q20-Heat Distributor.

Control systems

-

Enclosure

-

Mounting position

Wall mounted.

Protection

32 A.

User interface

LCD screen with push-button operation.

Functions

Manufacturer's standard.

Communications interface

VFC.

MODBUS RS485.

GSM.

Ancillary components

Temperature sensors, current transformers, reference meter.

Monitoring

-

Display the following conditions

-

Electrical properties

G98/G99 current transformers to measure building load.

Heat exchanger

Flow and return temperature.

Alarms

-

Engine

Run, standby, fault, fault code.

Accessories

Not required.

Flow master including flow master control without condensing technology - FM 50.

Flow master including flow master control without condensing technology - FM 150.

Flow master including flow master control without condensing technology - FM 250.

Flow master including flow master control without condensing technology - FM 350.

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Overall sound power level

63 dB.

Sustainability data

Country of product manufacture

Denmark

Manufacturing plant location

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Quality Management

Literature

LoadTracker XRGI® 6 CHP

LoadTracker XRGI® 6 CHP

LoadTracker XRGI® 9 CHP

LoadTracker XRGI® 9 CHP

LoadTracker XRGI® 15 CHP

LoadTracker XRGI® 15 CHP

LoadTracker XRGI® 20 CHP

LoadTracker XRGI® 20 CHP

Case studies

Ham Yard - CHP Case Story

Ham Yard - CHP Case Story

Glenogle Swim Centre- CHP Case Story

Glenogle Swim Centre- CHP Case Story

NHS Estate MacKinnon House

NHS Estate MacKinnon House

Castleoak - Case Story

Castleoak - Case Story

Case Story - Harvesters Way, Edinburgh

Case Story - Harvesters Way, Edinburgh