Verified by manufacturer 4 months ago
Lime Inhibitor for concrete surfaces prevents the 'leaching' of free lime from the concrete. It is easy to use, and supplies long term durability.
Newton CDM 906 is typically applied...
Lime Inhibitor For Application To Concrete Surfaces – Applied to concrete surfaces prior to the installation of a Newton cavity drain membrane waterproofing system to prevent the ‘leaching’ of free lime from the concrete.
Features and benefits:
Color | White |
Finish | Smooth |
Material | Liquid Guidance for specification option: Lime Inhibitor |
Shape | Formless Guidance for specification option: Form - single component: Low viscosity liquid |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | J40/335 Primers |
Product range |
Composition | Solvent-free. |
Specific gravity | 1.02. |
Weight | 1.1 kg. |
Yield – When mixed with 9 L of water | 10.0 L. |
Application rate – Open surface, porous concrete | 0.2 L/m². |
Application rate – Normal concrete | 0.1 L/m². |
Application rate – Power floated concrete | 0.08 L/m². |
Shelf life | 12 months. |
Application temperature | +5°C to +35°C. |
Service temperature | -15°C to +80°C. |
Odour | None. |
VOC content | None. |
Capacity | 1 L. Guidance for specification option: Pack size (plastic container). |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 0 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |