KS1000 LP Insulated Roof Panel System PIR - Steel

KS1000 LP Insulated Roof Panel System PIR - Steel

Kingspan Insulated Panels Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Kingspan Lo-Pitch Roof System is is designed to offer a architecturally striking, streamlined roofing solution.

Jump to:
+44 (0)1352 716100 www.kingspanpanels.co.uk
Application

Pitched roofs of 1.5° or more after deflection.

Description

Lo-Pitch (LP), secret-fix, shallow profiled, polyisocyanurate insulated roofing system with steel-faced panels and raised side joints.

Features and benefits:

  • Secret-fix appearance is created by elevated and capped fasteners clipped on site.
  • Panels are immune to attack from mould, fungi, mildew and vermin.
  • No urea-formaldehyde is used in the construction.
  • Panels are not deleterious.
  • An air leakage rate of 3 m³/hr/m² at 50 Pa or less can be achieved when the full building envelope is constructed using Kingspan panels.
  • Cover width: 1000 mm.

Applications:

Pitched roofs of 1.5° or more after deflection.

Approvals:

CE marked to BS EN 14509: 2013.

Fire:

  • The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Part 6: 2009 and Part 7: 1997).
  • The panel is rated SAA when tested to BS 476 Part 3: 2004.

- FIREsafe system:

  • FM approval to FMRC 4880 and 4471 Class 1 fire classification, unlimited height, for roof applications.
  • Reaction to fire classification according to BS EN 13501-1:2007+A1:2009: B-s1d0.
  • LPS 1181: 2014: Part 1: Issue 1.2, series of fire growth tests for LPCB approval and is certified to LPS 1181 Grade EXT-B.

Purlins, side rails and platforms supports:

Framed roof structure to be specified separately to include the following as required:

  • Multibeam purlins.
  • Multibeam eaves beams.
  • Cold-formed cleader angles.
  • Purlin cantilevers.
  • Cladding junctions.
  • Multichannel platform supports.
  • Multichannel trimmers.
  • Rafter stays (RNA/ RNB).

Warranties:

  • Maintenance and inspection free external coating: 40 years. Manufacturer’s external coating warranty to be available on project completion and be fully transferrable for future changes of building ownership.
  • Thermal performance: 25 years.
  • Structural performance: 25 years.

General information

Uniclass 2015

Ss_30_40_55_54 Metal insulating sandwich panel roof systemsPrimary

CAWS

H43/10 Metal insulating sandwich panel

H43/120 Metal insulating sandwich panel

Specification data - Metal insulating sandwich panel roof systems

Product Reference

KS1000 LP Insulated Roof Panel System - PIR, Steel

Design

Insert drawing reference or similar.

Roof pitch

Insert requirement; minimum 1.5° or more after deflection.

Panel

-

Core insulation

ECOsafe and FIREsafe polyisocyanurate (PIR)

Thermal conductivity

0.18 W/m²K

Core thickness: 115 mm; overall thickness: 150 mm.

0.21 W/m²K

Core thickness: 100 mm; overall thickness: 135 mm.

0.25 W/m²K

Core thickness: 80 mm; overall thickness: 115 mm.

0.31 W/m²K

Core thickness: 60 mm; overall thickness: 95 mm.

0.46 W/m²K

Core thickness: 45 mm; overall thickness: 80 mm.

External facing

-

Material

Steel, 0.5 mm-thick

Colour/ Finish

Kingspan Spectrum, Diamond, colour

Consult manufacturer's literature and insert requirements.

Kingspan Spectrum, Diamond, colour

Consult manufacturer's literature and insert requirements.

Kingspan Spectrum, Solid, colour

Consult manufacturer's literature and insert requirements.

Kingspan XL Forté™, Crescendo, colour

Consult manufacturer's literature and insert requirements.

Kingspan XL Forté™, Symphony, colour

Consult manufacturer's literature and insert requirements.

Kingspan XL Forté™, Vivace, colour

Consult manufacturer's literature and insert requirements.

Internal facing

-

Material

Steel, 0.4 mm-thick

Colour/ Finish

CLEANsafe 15

Kingspan AQUAsafe

Kingspan AQUAsafe 55

Kingspan CLEANsafe 120

Stainless steel

Panel length

See ‘Options’ and insert requirements

Primary fasteners

-

Number/ location

See ‘Options’ and insert requirements.

Handing

As design

Left handed

Right handed

Ridge filler

Not required

Profiled ridge filler

Cavity barriers

Not required

Kingspan Kooltherm®

Cavity closers

Not required

Kingspan Kooltherm®

Fascia

-

Material

As roofing panel

As design

Insert requirements.

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Soffit

-

Material

As roofing panel

As design

Insert requirements.

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Gutters

-

Type

Not required

Kingspan External Highline

Kingspan Insulated Membrane Lined

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Accessories

Consult manufacturer and insert requirements.

Flashings

Required

Not required

Rooflights

Not required

Kingspan Day-Lite Kapture

To be specified separately.

Personal fall protection

Not required

Safeside

To be specified separately.

Standard product features

Panel:

- Cover width:

1000 mm

- Single figure weighted sound reduction index (Rw):

25 dB.

Product Options

Roof pitch:

Pitches below 4° will require the external sheet of the panel to be turned for weathering on site as follows:

  • At the eaves: Turned down, typically by 20°.
  • At the ridge: Turned up, typically by 45°.

Roofing panels:

- External facing:

- Colour/ Finish:

  • ARS abrasion resistant: 28 µm-thick polyester or polyurethane resin reinforced with polyamide high durability coating with exceptionally good handling characteristics.
  • Kingspan XL Forté™, colour: Multi-layer organic coating, embossed with a traditional leather-grain finish.
  • Kingspan Spectrum, colour: Coated semi-gloss finish with slight granular effect.
  • Mill finish: Stucco embossed with lacquer.
  • Polyvinylidene fluoride (PVDF), colour: 25 µm-thick stoved fluorocarbon coating which has excellent colour stability even at temperatures as high as 120°C

- Internal facing:

- Colour/ Finish:

  • CLEANsafe 15: For use as the internal lining of insulated panels. Standard colour is “bright white” with an easily cleaned surface.
  • Kingspan AQUAsafe: Developed for use as the internal lining of insulated panels to suit high humidity internal environments.
  • Kingspan AQUAsafe 55: For use as the internal lining of insulated panels to swimming pool internal environments.
  • Kingspan CLEANsafe 120: For use as the internal lining of insulated panels where a high level of cleanliness and hygiene is required, and the panels are to be cleaned down on a regular basis.
  • Stainless steel: For use as the internal lining of insulated panels in buildings with a very aggressive or corrosive internal environment.

- Weight (0.5/ 0.4 mm steel):

  • 0.18 W/m²K: 12.5 kg/m².
  • 0.21 W/m²K: 11.9 kg/m².
  • 0.25 W/m²K: 11.1 kg/m².
  • 0.31 W/m²K: 10.3 kg/m².
  • 0.46 W/m²K: 9.7 kg/m².

- Length:

  • Standard lengths: 1.8–14.5 m, or insert drawing reference
  • Non-standard lengths of 14.5–29.3 m or <1.8 m are available on request; consult manufacturer for details.

- Primary fasteners:

  • Minimum two fasteners for each purlin position at sides of panel. Subject to wind loading; consult manufacturer's installation guide for details.
  • There may also be a requirement for applying a 4 mm diameter butyl rubber sealant / gun-grade vapour seal at the base of the side joint, dependant on project specification.

- Secondary fasteners:

- End laps:

  • 38 mm-long tail stitching screws with 19 mm sealing washers. Five per panel, applied from centre outwards, ensuring stitching screws penetrate the factory fitted stitching plate.

- Side joints:

  • Snap-on cover caps; Stitching screw or sealed rivet at eaves or through capping end lap. Anti-condensation tape (factory applied) between panels.
  • At all ridge locations, gun grade sealant to be applied across the panel side joints in line with the profiled ridge filler location, to close off the cover cap end.

Rooflights:

Rooflights are to be specified fully elsewhere - see Kingspan Light + Air or consult manufacturer for details.

Kingspan Energy:

- Solar photovoltaics:

Rooftop Solar PV can be installed onto insulated roof panels - consult manufacturer for details.

Digital objects
Platform Compatible Version Certified to
IFC
-

2

2.1
Revit
-

2

2.1
Download now from NBS National BIM Library
Literature
Third party certifications