Knauf Hybrid Isolator: II-70-070-6-1x15-SSP-1x15-PP-1x100(250/120)

Verified by manufacturer 3 days ago

Without deflection head arrangement

Knauf UK Variant:
Product certifications:
  • CCPI System

    CCPI System

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

  • EPD

    EPD

    Certificate type

Twin Frame system is typically used to divide habitable dwellings.

Jump to:
0800 521 050 Website

Application

Plasterboard partition system.

Description

Twin Frame system is typically used to divide habitable dwellings. The twin stud build up, combined with Knauf’s high performance plasterboards, maximizes acoustic performance in order to comply with building regulations, technical handbooks and guidance for sound insulation.

General information

Material

Gypsum

Metal

Glass mineral wool

Shape

Rectangle

Other

Square

Width

Bespoke

Height

Bespoke

Warranty description

Lifetime

Guidance for specification option:

Knauf Specification Disclaimer - Supply of Knauf products and systems for your project is typically made via distribution in accordance with Knauf’s ‘standard terms and conditions of sale.

Please be advised that Knauf’s design liability is strictly limited to the manufacture of its tested products and systems, in their tested arrangements, in accordance with the enclosed specification document, specification clauses and standard details. Knauf does not warrant nor accept any liability for the design, overall health and safety or functionality of any interfaces within the building between its stand-alone products and/or systems and any other sections or interfaces.

Download the full Specification Disclaimer here:

Knauf Specification Disclaimer | Knauf UK | NBS Source

View Knauf's Standard Terms and Conditions of Sale here:

Terms and Conditions of Purchasing from Knauf | Knauf

Manufacturer guidance

The 100% Knauf System Performance Warranty - Knauf warrants that its Systems will perform to the specified requirements throughout the lifetime of the building, when installed properly and under normal conditions.

The 100% Knauf System Performance Warranty guarantees that your Knauf systems are:

  • Manufactured from the highest quality raw materials in state-of-the-art factories. Products comply with UK and/or EU standards and are subject to rigorous quality assurance procedures.

  • System testing conducted at UKAS accredited laboratories or equivalent recognised (under ILAC MRA) European testing facilities for fire resistance and acoustic sound insulation testing with continuous factory production control testing to review and maintain published performances.

  • Fully supported at every stage of the project by Knauf’s market-leading technical and sales support personnel, both pre-site and during construction.

Download the full System Performance Warranty here:

The 100% Knauf System Performance Warranty | Knauf UK | NBS Source

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Specification data - Gypsum board partition systems

Classification data

Framing

Twin (double) Knauf 70 'I' (0.70) at 600 mm centres to suit maximum height.
Head channel: Knauf 72 'U' Channel (0.55). Floor channel: Knauf 72 'U' Channel (0.55).

Insulation

100 mm Knauf Insulation Acoustic Roll.

Linings

15 mm Knauf Soundshield Plus (Inner Layer each side) and15 mm Knauf Performance Plus (Outer Layer each side).

Fasteners

Inner layer (each side): 25 mm Knauf Performance Plus screws.
Outer layer (each side): 45 mm Knauf Performance Plus screws.

Joint treatment

Horizontal joint: Knauf Flat Fixing Plate.

Finish

-

Manufacturer guidance

For paint finishes: System must be taped and jointed using Knauf Joint Filler (Premium) or Knauf Joint Cement Premium and Knauf Joint Tape (Paper). Or alternative Knauf jointing compounds manufactured to EN 13963.

Knauf Wallboard Primer applied once taping and jointing completed.

Prior to where paint decoration is required. For preparation for decoration of where gypsum plaster skim is required, the outer layer of plasterboard joints is required to be taped and filled, using Knauf Joint Filler (Premium) and Knauf Joint Tape (Paper) meeting quality level 1 in accordance with Eurogypsum - Drywall Jointing and Finishing - Surface quality level classification.

For application where gypsum skim finish is required, the Knauf system is to be taped and filled using Knauf jointing compounds. When using Knauf Moisture Panel or Knauf Performance Plus, the applicator of gypsum skim finish is required to check if pre-treatment is required.

Fire resistance

EI 120 tested in accordance with EN 1364-1.

Sound insulation

65 dB when tested to BS EN 10140-2. 59 dB (Rw + Ctr) when tested to BS EN 10140-2.

Duty rating (to BS 5234-2)

Severe Duty in accordance with BS 5234-2. Clause 1.6.2 and 1.6.3 of Annex B and C.

System code

EN- II-70-070-6-1x15-SSP-1x15-PP-1x100(250/120).

Guidance for specification option:

System Code: EN- II-70-070-6-1x15-SSP-1x15-PP-1x100(250/120)

Maximum height: 4000 mm. The maximum height stated above is for the fire resistance of the system to meet project requirements where EN compliance is required. The stated maximum height figure is the lower value between the cold state height, calculated structurally to a limiting deflection of L/240 @ 200Pa and the fire state height, as outlined in accordance with EN 1364-1.

BS- II-70-070-6-1x15-SSP-1x15-PP-1x100(250/120).

Guidance for specification option:

System Code: BS- II-70-070-6-1x15-SSP-1x15-PP-1x100(250/120)

 Maximum height: 4000 mm. The maximum height stated above is for the fire resistance of the system to meet project requirements where EN compliance is required. The stated maximum height figure is the lower value between the cold state height, calculated structurally to a limiting deflection of L/240 @ 200Pa and the fire state height, as outlined in accordance with EN 1364-1.

Partition height

-

Manufacturer guidance

Insert requirements.

Partition thickness

250 mm.

Manufacturer guidance

Excluding finishes.

Sustainability data

Country of material origin

Spain

Manufacturer guidance

Applies to our natural gypsum only which is the main component of plasterboard. Other components are from other countries. Please contact Knauf for more details.

Country of product manufacture

United Kingdom

Manufacturer guidance

UK applies to the majority of manufacture but a small percentage of finished items may be imported. Please contact Knauf for more details.

Material

Gypsum
Metal
Glass mineral wool

Recyclability

Individual product EPDs for plasterboard and metal components available at: https://www.knauf.co.uk/our-services/resources/environmental-product-declarations-2

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

12.64 %

Manufacturer guidance

(2024 average by mass for all UK produced plasterboards, recycled gypsum & paper)

Product certifications

Product certifications

CCPI System

CCPI System

CCPI Assessment Certificate

EPD

EPD

Knauf Coreboard EPD

EPD

EPD

Knauf Soundshield Plus EPD

EPD

EPD

Knauf Performance Plus EPD

EPD

EPD

Knauf Internal Metal Partition Components EPD

EPD

EPD

Knauf Insulation Acoustic Roll 75mm & 100mm EPD

Literature

Knauf Core Board Data Sheet

Knauf Core Board Data Sheet

Knauf Soundshield Plus Data Sheet

Knauf Soundshield Plus Data Sheet

Knauf Performance Plus Data Sheet

Knauf Performance Plus Data Sheet

Knauf Performance Plus Screws Data Sheet

Knauf Performance Plus Screws Data Sheet

Knauf DF U Channel Data Sheet

Knauf DF U Channel Data Sheet

Knauf U Channel Data Sheet

Knauf U Channel Data Sheet

Knauf Flat Fixing Plate Data Sheet

Knauf Flat Fixing Plate Data Sheet

Knauf I Stud Data Sheet

Knauf I Stud Data Sheet

Knauf Fill and Finish Light Data Sheet

Knauf Fill and Finish Light Data Sheet

Knauf Intumescent and Acoustic Mastic Data Sheet

Knauf Intumescent and Acoustic Mastic Data Sheet

Knauf Paper Joint Tape Data Sheet

Knauf Paper Joint Tape Data Sheet

Knauf Insulation Acoustic Roll Data Sheet

Knauf Insulation Acoustic Roll Data Sheet

Knauf Systems Performance Tables (BS Compliance)

Knauf Systems Performance Tables (BS Compliance)

Knauf Systems Performance Tables (EN Compliance)

Knauf Systems Performance Tables (EN Compliance)

The 100% Knauf System Performance Warranty

The 100% Knauf System Performance Warranty

Knauf Specification Disclaimer

Knauf Specification Disclaimer

Knauf Fire Rated Deflection Heads Document

Knauf Fire Rated Deflection Heads Document

Similar products from Knauf UK

Knauf 'I' Stud Lining (fire resistance system): ISL-I-70-070-6-2x15-FP-50

Knauf 'I' Stud Lining (fire resistance system): ISL-I-70-070-6-2x15-FP-50

Knauf 'I' Stud Lining (fire resistance system): ISL-I-92-090-6-2x15-FP-50

Knauf 'I' Stud Lining (fire resistance system): ISL-I-92-090-6-2x15-FP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-3-2x15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-3-2x15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-4-1-12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-4-1-12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1-12.5-MP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1-12.5-MP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x12.5-WB-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x15-SSP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-1x15-SSP-0

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-12.5-WB-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-12.5-WB-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-25

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-50

Knauf 'I' Stud Lining (non-fire resistance system): ISL-I-50-055-6-2-15-SSP-50