NBS Source
I'm a manufacturer
Compare variants

Kingspan Kooltherm Duct Insulation

Verified by manufacturer 1 month ago

KoolthermDuct-20

Kingspan Insulation Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 37301 (Compliance Management Systems)

    Certificate type

  • EPD

    EPD

    Certificate type

An energy-efficient rigid insulation for rectangular, circular and flat oval HVAC ductwork.

Jump to:
BOS
+44 (0)1544 388601 Website

Application

Suitable for use on rectangular, circular and flat oval ductwork in HVAC or building services applications.

Description

Energy-efficient rigid insulation for rectangular, circular and flat oval HVAC ductwork suitable for new build and refurbishment projects in the residential, commercial, institutional and industrial sectors. Comprised of a fibre-free rigid phenolic insulation core externally faced with an aluminium vapour barrier foil and internally with a glass tissue based facing.


Insulated duct support inserts:

During the installation of galvanised steel ductwork, the contractor should place insulated support inserts between ducts and supports, to extend both sides of the support to allow for tape application. Insulated duct support inserts should be of suitable compressive strength to carry the loads transmitted to the supports and should be of the same thickness as that of the adjacent duct insulation.


Features and benefits:

  

  • manufactured with a CFC / HCFC-free blowing agent that has very low Ozone Depletion Potential (ODP) and low Global Warming Potential GWP < 5.
  • BS EN ISO 9001: 2015 (Quality management systems. Requirements), BS EN ISO 14001: 2015 (Environmental Management Systems. Requirements)
  • BS ISO 45001: 2018 (Occupational health and safety management systems) and BS EN ISO 50001: 2018 (Energy Management Systems).

General information

Color

Pink

Finish

Smooth

Foil

Material

Phenolic foam

Length

1200 mm

Width

600 mm

2400 mm

Height

Uniclass

Pr_80_77_76_62 Phenolic foam insulationPrimary

CAWS

U90/490 Site-applied insulation to ductwork

U90/490 Site-applied insulation to ductwork

U90/425 Rigid ductwork and fittings

U90/425 Rigid ductwork and fittings

Product range

Ducting

Specification data - Phenolic foam insulation

Standard

To BS EN 14314:2009+A1:2013.

Form

Duct slab.

Thermal conductivity

0.024 W/m K at -20°C.

0.022 W/m K at 10°C.

0.023 W/m K at 19°C.

0.023 W/m K at 25°C.

0.026 W/m K at 50°C.

0.031 W/m K at 80°C.

Finish

Exposed aluminium foil facing.

Fire performance

To BS EN 13501-1, class B-s2, d0 (exposed foil face); class E (non exposed tissue face).

Insulation thickness (minimum)

20 mm.

Vapour barrier

-

Material

Factory-applied aluminium foil.

Guidance for specification option:

Standard for indoor use.

Protection

Not required.

Waterproof finish.

Guidance for specification option:

If the ductwork is to the external of the building the insulation must be covered with a waterproof finish.

Accessories

Not required.

Aluminium tape.

Guidance for specification option:

Insulation is applied to ductwork with high strength aluminium tape.

Adhesive.

Guidance for specification option:

When tape is not sufficient, use adhesive, or mechanical means, or a combination of both.

Bands (preferably aluminium).

Guidance for specification option:

Bands (preferably aluminium) and matching seals are used as additional mechanical means on circular ductwork.

FM approved

FM Approved per Approval Standard 4924 as a low fire hazard.

Guidance for specification option:

Kingspan Kooltherm® Duct Insulation is FM Approved per Approval Standard 4924 as a low fire hazard, which does not require automatic sprinkler protection of itself, when manufactured and installed in accordance with the conditions defined by the approval report.

Compressive strength (minimum)

100 kPa at 10% compression.

Closed cell content

≥90%.

Nominal density range

35–40 kg/m³.

Face Size (length x width)

600 x 1200 mm.

1200 x 2400 mm.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Phenolic foam

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

2.77 kg CO₂ eq/kg

Guidance for specification option:

Per EPD, Kooltherm Duct has an embodied carbon content of 9.14e+0 per functional unit, divided by 3.3 kg/m2 = 2.77 kg CO2 eq per kg.

Manufacturer guidance

1 m² of Kooltherm Duct insulation at a thickness that gives an R-value of 3.000 m².K/W (66mm) gives a GWP of 9.14 kg CO2 equivalent per functional unit, in Life cycle stages A1 - A3 (Raw material supply, transport and manufacturing). This is equivalent to 2.77 kg CO2e/kg of Kooltherm Duct Insulation

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 - Pembridge

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001:2018 - Pembridge

ISO 37301 (Compliance Management Systems)

ISO 37301 (Compliance Management Systems)

ISO 37301:2021 - Pembridge

EPD

EPD

BREG EN EPD No: 000362

Literature

Kingspan Kooltherm Duct Insulation - 05/23

Kingspan Kooltherm Duct Insulation - 05/23

Similar products from Kingspan Insulation

Kingspan Kooltherm Pipe Insulation

Kingspan Kooltherm Pipe Insulation