NBS Source
I'm a manufacturer
Compare variants

Kingspan KoolDuct System - Pre-insulated HVAC Ductwork System

Verified by manufacturer 8 days ago

Kingspan KoolDuct System - 30 mm

Kingspan Insulation Variant:
Third party certifications:
  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • EnMS ISO 50001

    EnMS ISO 50001

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • ISO 37301 (Compliance Management Systems)

    Certificate type

  • EPD

    EPD

    Certificate type

Energy efficient, lightweight pre-insulated rectangular HVAC ductwork system with low air leakage. Fabricated with premium performance Kingspan KoolDuct® phenolic panels.

Jump to:
BOS
+44 (0)1544 388601 Website

Application

The Kingspan KoolDuct System of pre-insulated ductwork is designed for use in building services / HVAC applications. It is suitable for both new build and residential, commercial, public, light industrial and leisure sectors.

Description

Designed for mechanical ventilation, heating and air-conditioning systems, The Kingspan KoolDuct System is suitable for both new build and refurbishment projects in the residential, commercial, public, light industrial and leisure sectors. Moreover, it is especially suitable for use in nonferrous applications such as MRI scanning units in hospitals, and on other high specification projects where non-fibrous insulants may be preferred.


Ductwork design and frictional resistance:

Kingspan KoolDuct rectangular ductwork, including fittings, follows the same calculation principles and duct sizing methods as are used for rectangular metal ductwork.

The frictional resistance is comparable with that of galvanized sheet steel ductwork.


Features and benefits:

  • Low air-leakage – can meet meet air–leakage Class C and D (ref. BS EN 1507: 2006; BS EN 13403: 2003 and BESA DW/144).
  • Installed cost savings – can provide an ideal value engineered ductwork solution.
  • Space saving – fits flush to ceiling.
  • Faster installation – up to three times faster.
  • Single fix installation – one less trade onsite and less disruption for others.
  • Over 70% lighter than sheet metal ductwork) – can overcome severe constraints on structural loading.
  • Non-fibrous insulation.


Operational limits:

The recommended operational limits for ductwork fabricated from the Kingspan KoolDuct® System:

  • Mean air velocity (maximum): 25.4 m/s.
  • Design pressure (maximum): Positive: 1000 Pa, Negative: 750 Pa.
  • Internal air temperature: -20ºC to +80ºC during continuous operation.
  • Size: Unlimited (provided that recommended Kingspan KoolDuct® fabrication techniques and installation procedures are strictly observed)
  • Outdoor ductwork must be protected with a compatible weatherproof.


Standards:

- Quality Control:

Kingspan KoolDuct panels are manufactured to the highest standards under a management system certified to:

  • BS EN ISO 9001: 2015 (Quality Management Systems. Requirements).
  • BS EN ISO 14001: 2015 (Environmental Management Systems. Requirements).
  • BS ISO 45001: 2018 (Occupational health and safety management systems) and
  • BS EN ISO 50001: 2018 (Energy management systems. Requirements with guidance for use).


Sustainability:

The insulation core of Kingspan KoolDuct® panels is manufactured with a CFC / HCFC-free blowing agent that has very low Ozone Depletion Potential (ODP) and low Global Warming Potential GWP < 5.

BREEAM – ductwork fabricated from The Kingspan KoolDuct® System can contribute directly, and indirectly, toward the achievement of credits in the building rating system, BREEAM. The relevant credits are Ene1 – Reduction of energy use and carbon emissions Mat 1 – Life Cycle Impact, Mat 3 – Responsible sourcing of materials.

General information

Color

Grey

Pink

Finish

Foil

Material

Phenolic foam

Shape

Other

Length

2950 mm

Width

1200 mm

Height

22 mm

30 mm

Uniclass

Pr_65_65_25_64 Pre-insulated ductwork and fittingsPrimary

CAWS

U90/670 Rigid ductwork generally

U90/425 Rigid ductwork and fittings

Product range

Koolduct

Specification data - Pre-insulated ductwork and fittings

Standard

To BS EN 13403.

Insulation material

Phenolic foam (PF).

Internal and external material

Phenolic insulation is covered by factory-applied aluminium foil facings on both sides.

Finish

Aluminium foil facing.

Accessories

-

Material

Compatible with ductwork.

Finish

To match ductwork.

Access openings

-

Purpose

Inspection.

Sizes

To BS EN 12097.

Execution

Air ductwork generally.

ThermalConductivity

0.023 W/m·K at -20°C, 0.022 W/m·K at 10°C, 0.023 W/m·K at 19°C, 0.024 W/m·K at 25°C, 0.027 W/m·K at 50°C, 0.031 W/m·K at 80°C.

Standard

BS EN ISO 9001: 2015 (Quality Management Systems. Requirements), BS EN ISO 14001: 2015 (Environmental Management Systems. Requirements), BS ISO 45001: 2018 (Occupational health and safety management systems) and
BS EN ISO 50001: 2018 (Energy management systems. Requirements with guidance for use), BS EN 14314:2009+A1:2013

Insulation thickness (minimum)

30 mm.

Vapour barrier material

Factory-applied aluminium foil (standard for indoor use) vapour .barrier facing

Protection

If the duct system is to the external of the building it has to be protected by one of the following: aluminium sheet, aluminium–zinc alloy coated steel sheet, heavy-duty self-adhesive laminate, reinforcing glass/ synthetic cloth embedded between two coats of appropriate coating or UV resistant glass reinforced polyester/ epoxy (GRP/ GRE).

Accessories

For duct assembly: Either tiger clips or adhesive, aluminium foil tape and silicone sealant. Flanges/ couplings: tiger clips or 4-bolt flange/ aluminium grip flange with bayonet cleat. Reinforcements / stiffners: Tie rods/Reinforcing bars.

Reaction to fire classification

Euroclass B-s1,d0 exposed foil side and C-s2,d0 non-exposed foil side.

FM approved

No (not applicable to pre-insulated ductwork for HVAC application).

Compressive strength (minimum)

>175 kPa at 10% compression.

Closed cell content

≥90%.

Nominal density range

55–60 kg/m³.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Phenolic foam

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

3.36 kg CO₂ eq/kg

Manufacturer guidance

1 m² of insulation at a thickness that gives an R-value of 3.000 m².K/W (66mm) gives a GWP of 13.3 kg CO2 equivalent per functional unit, in Life cycle stages A1 - A3 (Raw material supply, transport and manufacturing). For KoolDuct this is equivalent to 3.36 kg CO2e/kg

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO 14001:2015 - Pembridge

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001:2018 - Pembridge

EnMS ISO 50001

EnMS ISO 50001

ISO 50001:2018 - Pembridge

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 - Pembridge

ISO 37301 (Compliance Management Systems)

ISO 37301 (Compliance Management Systems)

ISO 37301:2021 - Pembridge

EPD

EPD

BREG EN EPD No: 000361

Literature

The Kingspan KoolDuct System, datasheet - 04/23

The Kingspan KoolDuct System, datasheet - 04/23

The Kingspan KoolDuct System, introduction - 04/23