NBS Source
I'm a manufacturer

Keystone Non Combustible Cavity Tray Lintels (NCCTL) - Standard/ Heavy/ Extra Heavy Duty

Verified by manufacturer 4 months ago

Keystone Lintels Ltd Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • BS EN 1090-1

    BS EN 1090-1

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

Cavity >50 mm | BBA | Part L & B Compliant | UKCA | CE | Galvanized & Stainless

Jump to:
028 86 762184 Website

Application

  • For use in an exterior masonry skin in conjunction with a non-masonry inner leaf such as a steel frame system (SFS) to support masonry above window and door openings.
  • Cavity widths greater than 50 mm.
  • Lintels should be installed with a minimum end bearing of 150 mm, product end bearing varies (consult Keystone's Technical Department), bedded on mortar and levelled along its length and across its width.
  • The masonry above the lintel should be built in accordance with BS EN 1996-2.
  • Masonry should be laid on a mortar bed and all perpendicular joints should be filled.
  • The NCCTL is a practical solution which is built into the outer leaf as normal and facilitates easy access for the profiling of insulation and the overlap positioning of the cavity facing membrane if required (this should be completed independently, once the lintel is securely built into the brickwork).
  • Point loads should not be applied directly onto lintel flanges. Lintels should have a minimum of 150 mm masonry between the flange and the application level of any form of loading. Consult Keystone’s Technical Department if applying a point load above a lintel.
  • The external lintel flange must project beyond the window/door frame and it is recommended that a flexible sealing compound is used between the underside of the lintel flange and the frame.
  • Do not cut lintels to length or modify them in any way without consulting a Keystone engineer.
  • Masonry should not overhang any flange by more than 25 mm.
  • The practice of propping a lintel is sometimes used to facilitate speed of construction. It should only be introduced after initial masonry load has been applied to the lintel.
  • Stop ends are mechanically fixed onto the NCCTL at each end to prevent moisture cascading over the ends into the cavity and onto the inside wall.
  • At least two weep vents are required per opening and positioned not more than 450 mm apart.

Description

All Keystone Non Combustible Cavity Tray Lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F and Scotland’s Technical Handbook, section 6. The NCCTL satisfy fire safety requirements of Approved Document B of the Building Regulations within buildings over 11 m in height.


Reaction to fire classification = A1 (non combustible) in accordance with BS EN 13501-1 as defined in 96/603/EC. Meets the requirements of material/coating specification requirements within PD6697. The Keystone patented NCCTL prevents thermal bridging. Keystone's NCCTL conforms to the requirements of a cavity tray satisfying the NHBC & LABC technical guidance.


The NCCTL patented mechanically fixed stop ends are prepositioned within perpend joints to accommodate brickwork openings. The installation of the NCCTL requires no additional specialist skills. The ease of installation in the outer leaf combines the structural load bearing lintel with the advantages of a self-supporting cavity tray.


For more detailed information applicable to a particular wall construction, contact Keystone Lintels Technical Department. Refer to manufacturers literature for details regarding lintel ranges, height, thickness and Uniformly Distributed Load (UDL) figures.


Performance:

Fire:

  • A1 - Non Combustible.
  • Keystone's Non Combustible Cavity Tray Lintels have been subjected to a fire test (Report No. 526744/R) in accordance with BS EN 1363-1, at Exova Warrington Fire and achieved a two hour fire performance.

Corrosion:

  • All Keystone’s range of Non Combustible Cavity Tray Lintels are manufactured from austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Upon request, other grades of stainless steel lintels are available conforming to BS EN 845-2.
  • The use of austenitic stainless steel is ideal when the life expectancy and maintenance programme of a building are key considerations. 
  • Material / coating specification in buildings exceeding three storeys in a non-aggressive environment should be limited to austenitic stainless steel (chrome nickel alloys). 
  • Material / coating specification for buildings in an aggressive environment (e.g. coastal sites) should be limited to austenitic stainless steel (molybdenum chrome nickel alloys).

Structural:

  • The Keystone lintel range has safe working loads as detailed in each applicable loading table in the Keystone Lintels NCCTL brochure.
  • The structural performance figures within each table have been ascertained by testing in accordance with the requirements of standards BS EN 5977-2, BS EN 846-9 and BS EN 845-2.

Certification:

  • BBA Agrement certificate 00/0000 including regular assessment of production (pending).
  • UKCA Assessment of performance, System 3.
  • CE Assessment of performance, System 3.
  • EN 1090-2 Execution Class 2, Declaration method 1,2,3a & 3b, Certificate 14/F106 & 14/F107.
  • ISO 9001 Quality Management Systems, Certificate 18/Q059.
  • ISO 14001 Environmental Management Systems, Certificate 18/E019.

Galvanized steel:

  • Keystone’s range of Non Combustible Cavity Tray Lintels can be manufactured from high quality grade mild steel to BS EN ISO 1461 DX51D with a zinc coating of 710 g/m² conforming to BS EN 845-2.

Additional features:

  • Free scheduling and specification service.
  • Keystone Steel lintels have a service life commensurate with that of the building in which they are installed.
  • Keying options to suit required plastering applications.
  • Cavity closer.
  • Cant brick.
  • Powder coating.
  • Stainless steel weep holes.
  • Bespoke.

Contact Keystone Lintels Technical Department for further information.

General information

Color

Silver

Finish

Metallic

Galvanized

Material

Steel

Guidance for specification option:

  • Galvanized mild steel to BS EN ISO 1461 DX51D with a zinc coating of 710 g/m². Material Coating Ref L10.

Stainless steel

Guidance for specification option:

  • Austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3.
  • Austenitic stainless steel, grade 316 2b BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1.

Length

-

Manufacturer guidance

Refer to Keystone Steel Lintel Manual or contact Keystone Lintels Technical Department.

Uniclass

Pr_20_85_48_11 Carbon steel lintelsPrimary
Pr_20_85_48_84 Stainless steel lintels

CAWS

F30/755 Prefabricated steel lintels

F30/85 Prefabricated steel lintels

Specification data - Carbon steel lintels

Standard

To BS EN 845-2.

Guidance for specification option:

UKCA and CE Marked to BS EN 845-2 Specification for ancillary components for masonry Part 2: Lintels.

Manufacturer guidance

Declaration of Performance certificates are available at: www.keystonelintels.com.

Lintel type

Composite.

Material finish and coating reference

Galvanized mild steel to BS EN ISO 1461 DX51D with a zinc coating of 710 g/m². Material Coating Ref L10.

Austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3.

Austenitic stainless steel, grade 316 2b BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1.

Sizes

As Lintels schedule.

Characteristics

-

Resistance to fire

Has achieved a minimum period of 120 minutes in accordance with BS EN 1363-1.

Thermal conductivity

Part L compliant.

Duty

Standard duty.

Heavy duty.

Extra heavy duty.

Accessories

Not required.

Keying options to suit required plastering applications.

Cavity closer.

Cant brick.

Powder coating.

Show more

Sustainability data

Recyclability

100% Recyclable

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

65 %

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

BBA - 98/3493 | Keystone Steel Lintels

BBA Agrément Certificate

BBA Agrément Certificate

BBA - 18/5499 | Keystone Hi-Therm+

BS EN 1090-1

BS EN 1090-1

EN 1090-1 | Cookstown

BS EN 1090-1

BS EN 1090-1

EN 1090-1 | Swadlincote

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

Literature

Keystone Lintels Steel Lintel Manual

Keystone Lintels Steel Lintel Manual

NCCTL Non-Combustible Cavity Tray Lintel

NCCTL Non-Combustible Cavity Tray Lintel

Case studies

Borth - Bow Lintels

Borth - Bow Lintels

Disraeli Park - Bespoke Brick Feature Splayed Bay System

Disraeli Park - Bespoke Brick Feature Splayed Bay System

Church Farm Barns - Brick Slip Feature Lintels

Church Farm Barns - Brick Slip Feature Lintels

Station Approach - Brick Slip Feature Lintels

Station Approach - Brick Slip Feature Lintels

Similar products from Keystone Lintels Ltd

Keystone Box Lintels - Standard/ Heavy/ Extra Heavy Duty

Keystone Box Lintels - Standard/ Heavy/ Extra Heavy Duty

Keystone Brick Slip Feature Lintel - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Brick Slip Feature Lintel - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Wide Inner Leaf - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Wide Inner Leaf - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Wide Outer Leaf - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Cavity Wall Lintels - Wide Outer Leaf - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Hi Therm + Cavity Wall Lintels - Standard/ Heavy/ Extra Heavy Duty

Keystone Hi Therm + Cavity Wall Lintels - Standard/ Heavy/ Extra Heavy Duty

Keystone Roller Shutter Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Roller Shutter Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Single Leaf Lintels - Standard/ Heavy Duty

Keystone Single Leaf Lintels - Standard/ Heavy Duty

Keystone Solid Wall Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Solid Wall Lintels - Standard/ Heavy/ Extra Heavy/ Extreme

Keystone Specials & Sunlounge Lintels  - Special Steel Lintels