NBS Source
I'm a manufacturer
Compare variants

Kamstrup Multical

Verified by manufacturer 2 months ago

403-Qp 0.6 - G3/4B x 110 mm

S.A.V. Systems Variant:

Flexible heat metering solution.

Jump to:
+44 01483 771 910 Website

Application

Suitable for a variety of applications including: billing and energy performance monitoring of utilities, sub-metering, residential, and commercial.

Description

Fully flexible heat metering solution.


Features and benefits:

  • Fully programmable data logger with minute loggers.
  • Two second integration interval.
  • 16 years battery lifetime at a reading interval down to ten seconds.
  • Eight digit display resolution.
  • User-friendly interface with push buttons for navigation.
  • Communication modules available (M-Bus with two pulse inputs, M-Bus with two pulse outputs, wireless M-Bus, M-Bus with disconnect, analogue inputs, analogue outputs, LoRaWAN, BACnet, MODBUS).
  • Battery or mains powered (230 V or 24 V).
  • Threaded connections available up to 2" and flanged connections above DN-20.
  • Built-in M-Bus as standard. (603 only)
  • Up to two communications modules. (603 only)
  • Auto detect of ULTRAFLOW® for easy maintenance and installation. (603 only)
  • Extended cables for flow and temperature probes, up to 30 metres. (603 only)

General information

Color

White

Material

Plastic

Shape

Rectangle

Length

40 mm

47 mm

Width

128 mm

166 mm

Height

102 mm

110 mm

Warranty description

Two year

Material

Plastic

Uniclass

Pr_80_51_51_37 Heat metersPrimary

CAWS

T90/110 Heating system

Specification data - Heat meters

Third-party certification

MID-2014/32/EU, DK-0200-MI004-008, DK-0200-MI004-033, DK-0200-MID-D-001.

Format

In line.

Display

Remote.

Orientation

Horizontal.

Temperature sensors

Direct.

In-direct.

Temperature range

2–130°C.

Flow rate

-

Nominal

0.6 m³/h.

Maximum

1.2 m³/h.

Connection

-

Type

Threaded.

Size

G3/4B x 110 mm.

Mechanical classification

M2.

Ingress protection (minimum)

IP65.

Power supply

Mains 230 V.

Integral battery with minimum 16 year life.

Communication interfaces

M-bus & 2x pulse inputs.

M-bus & 2x pulse outputs.

Modbus & 2x pulse inputs.

BACnet & 2x pulse inputs.

M-Bus and M-Bus disconnect.

Wireless M-Bus & 2x pulse inputs.

Analog input module.

Analog output module.

Wireless OMS-LPWAN modules.

Wireless OMS-LPWAN module with disconnect.

Accessories

-

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Flow rate minimum

0.006 m³/h.

Sustainability data

Country of product manufacture

Denmark

Material

Plastic

Manufacturing plant location

Expected Life

20 year

Literature

Kamstrup Multical 403

Kamstrup Multical 403

Kamstrup Multical 603

Kamstrup Multical 603