NBS Source
I'm a manufacturer

IG Windposts - U, DU, LP

Verified by manufacturer 4 months ago

IG Lintels Third party certifications:
  • BS EN 1090-1

    BS EN 1090-1

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Cavity Wall | Solid Wall | UKCA | CE | Stainless Steel

Jump to:
+44 (0)1633 486486 Website

Application

  • Stainless steel windposts for use in cavity wall or solid wall construction providing lateral restraint to supporting walls.
  • The masonry should be built in accordance with BS EN 1996-2.
  • Wall ties should be installed into the mortar joint with a minimum embedment of 50 mm.
  • Do not cut windposts to length or modify them in any way without consulting an IG engineer. 

Description

IG Windposts span vertically between floors to provide additional lateral support for large panels of brickwork or large panels with openings. Supplied with specially designed base connections and top connections appropriate for each construction configuration. Windposts have pre-cut slots to accommodate the required number of wall ties designed for the masonry coursing. Supplied with a suitable number of wall-ties which will vary in relation to the post type and the cavity width. Special lengths available in all ranges to suit parapets or below windows.


For more detailed information applicable to a particular wall construction, contact IG Lintels Technical Department. Refer to manufacturers literature for details regarding windpost ranges, height, thickness and Uniformly Distributed Load (UDL) figures.


Range:

U Windpost:

  • The U windpost is a channel section designed for standard loading conditions and is installed within the cavity.

DU Windpost:

  • The DU windpost is a "back to back" channel section designed for heavier loading conditions and is installed within the cavity.

LP Windpost:

  • The LP windpost is an "L" shaped section designed to suit a range of loading conditions and is built into the inner leaf of a cavity wall.

General information

Color

Silver

Material

Stainless steel

Guidance for specification option:

  • Austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307) Material Coating Ref 3.
  • Austenitic stainless steel, grade 316 2b BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404) Material Coating Ref 1.

Length

-

Manufacturer guidance

Refer to IG Lintels Product Guide brochure or contact IG Lintels Technical Department.

Uniclass

Pr_20_85_16_96 Wind postsPrimary

CAWS

F30/255 Wind posts

Specification data - Wind posts

Material

Austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref 3.

Austenitic stainless steel, grade 316 2b BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref 1.

Sizes

-

Span (length)

Guidance for specification option:

Refer to IG Lintels Product Guide brochure or contact IG Lintels Technical Department.

Standard

Designed to Eurocodes 3.

Guidance for specification option:

UKCA and CE Marked to EN 1090-1 Execution of steel structures and aluminium structures - Requirements for conformity assessment of structural components.

Duty

Standard duty.

Heavy duty.

Accessories

Not required.

Wall ties.

Debonding sleeve.

Frame cramp.

Base plate.

Show more

Sustainability data

Recyclability

100% recyclable

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

85 %

Third party certifications

BS EN 1090-1

BS EN 1090-1

EN 1090-1 | Cookstown

BS EN 1090-1

BS EN 1090-1

EN 1090-1 | Swadlincote

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

BBA Agrément Certificate

BBA Agrément Certificate

BBA - 05/4192 | IG Steel Lintels

BBA Agrément Certificate

BBA Agrément Certificate

BBA - 15/5250 | IG MSS Brick Slip Feature Lintels

BBA Agrément Certificate

BBA Agrément Certificate

BBA - 18/5533 | IG Hi-Therm+

Literature

IG Lintels Product Guide

IG Lintels Product Guide

NCCTL Non-Combustible Cavity Tray Lintel

NCCTL Non-Combustible Cavity Tray Lintel

Case studies

Chocolate Works - Corner Lintels, Windposts & Standard Lintels

Chocolate Works - Corner Lintels, Windposts & Standard Lintels

Holland Park Phase 2 - Hi-therm+ Lintels & Windposts

Holland Park Phase 2 - Hi-therm+ Lintels & Windposts