NBS Source
I'm a manufacturer
Compare variants

Hydraulic Hatch - Sky.by.cantifix - Hydraulically Lifted Hinged Rooflight

Verified by manufacturer 1 month ago

Hydraulic hinge - bespoke configuration

Cantifix Ltd Variant:
Third party certifications:
  • Weathertightness Testing

    Certificate type

Hydraulically lifted hinged rooflight and floor for ventilation and pedestrian access.

Jump to:
+44 (0)20 8203 6203 Website

Application

Rooflights and ventilation to an enclosed area below.

Description

Hydraulically lifted hinged rooflight and floor for ventilation and pedestrian access.


Features and benefits:

  • To bring ventilation to an enclosed area below without compromising safety or security.
  • Can be used as a walk-on floor by increasing glass thickness.
  • Thermally broken aluminium profile with fully cleated corners. Reinforced with stainless steel flats as required.
  • Frame is fully welded stainless-steel angles thermally isolated with GRP profiles.
  • Standard clear double-glazed units with a variety of low-E coating to give a minimum centre pane U-value of 1.1 W/m²K.
  • All glass is safety glass in either toughened or heat-strengthened laminate.
  • Options include low iron glass, solar control coatings along with acoustic or security interlayers.

General information

Color

Clear

Guidance for specification option:

Glass.

Other

Guidance for specification option:

Framing.

Material

Glass

Aluminium

Stainless steel

Steel

EPDM

Show more

Shape

Rectangle

Square

Length

Bespoke

Width

Bespoke

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Size

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Product performance

-

Whole window U-value

To BS EN 10077, <1.4 W/m²K.
1.1 W/m²K (centre pane, minimum).

Guidance for specification option:

Consult manufacturer for details based on related details, or U-value requirements.

Frame

-

Material

Aluminium.

Manufacturer guidance

Thermally broken aluminium profile with fully cleated corners. Reinforced with stainless steel flats as required.

Fully welded stainless-steel angles thermally isolated with GRP profiles.

Finish

-

Coating

Powder coating.

Colour

Guidance for specification option:

Insert requirements; powder coated in any standard RAL colour.

Film thickness (minimum)

Manufacturer's standard.

Glazing or infill

-

Type

Toughened safety glass.

Heat-strengthened laminate safety glass.

Other.

Guidance for specification option:

Consult manufacturer for alternatives and insert requirements.

Options include low iron glass, along with acoustic or security interlayers.


See Glazing or infill - Coating below for further options.

Construction

Double glazed.

Manufacturer guidance

Consult manufacturer for further details. Glass thickness is application-dependent.

Colour

Clear.

Coating

Low-E to achieve minimum centre pane U-value.

Guidance for specification option:

Standard.

Solar control.

Operation

-

Type

Powered, hydraulic.

Guidance for specification option:

Hydraulic pistons operated via a remotely located pump.

Control

By dead-man operation.

External control through rain, wind and light sensors.

External control through biometric device.

External control through remote-control handset.

Manufacturer guidance

See also Power supply for UPS option.

Power supply

Standard.

Uninterrupted power supply (UPS).

Guidance for specification option:

Achieved by installing a battery backup to allow for operation even during power outage.

Ironmongery

All fittings in aluminium, stainless steel (304), printed from ABS material or other non-corrosive material.

Guidance for specification option:

Consult manufacturer for details as required.

Air permeability

To BS EN 12207, Class 4 at 600 Pa.

Resistance to wind load

To BS EN 12210, Class E2400.

Watertightness

To BS EN 12208, Class 9A.

Performance characteristics

CWCT classification (TN92): Class 2 (if four-edge supported and panels <4.5 m²).

Sustainability data

Contains Red List materials

No

Country of material origin

Poland

Country of product manufacture

Poland

Material

Glass

Aluminium

Stainless steel

Steel

EPDM

Show more

Manufacturing plant location

Expected Life

25 year

Third party certifications

Weathertightness Testing

Weathertightness Testing

Weathertightness Testing - Hydraulic Rooflight

Literature

L11 - sky.by.cantifix Hydraulic hinged Rooflight / Floor

L11 - sky.by.cantifix Hydraulic hinged Rooflight / Floor