Horizontal sliding secondary glazing unit. Five panel configuration.

Jump to:
+44 (0) 1909 499899 Website

Application

Internal horizontal sliding secondary glazing window unit - with a five panel configuration. Can be used in a combination to treat large areas. Suitable for all commercial and residential applications.

Description

A slim and versatile horizontal sliding system that provides easy access for cleaning and ventilation, and is suitable for treating most window types. Five panel configuration.


Features and benefits:

  • Slim, unobtrusive aluminium profile.
  • Smooth sliding action on panels for easy operation using brass wheels.
  • All panels lift out for complete access to primary window.
  • Improved noise and thermal installation.
  • Suitable to have bevelled timber subframe to fix into bays / splayed reveals.
  • Can be coupled or stacked with other units in the range to treat large areas of glazing or long runs of windows.
  • Woolpile inserted into panel section groove to create outer frame seal.
  • Gasket colour – Black as standard, white also available upon request.
  • PVC-U trims supplied for the face of the units to create a neat, clean finish.
  • Standard colour 9003 Satin White.
  • Unit available with no subframe

General information

Color

White

Other

Manufacturer guidance

All RAL colours available.

Finish

Powder-coated

Manufacturer guidance

All coloured units are powder-coated in house at the manufacturer's painting facility.

Material

Aluminium

Glass

Timber

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Guidance for specification option:

4900 mm (maximum).

Height

Bespoke

Warranty description

Ten year

Uniclass

Pr_30_59_98_02 Aluminium window unitsPrimary

CAWS

L10/53 Secondary glazing system

L10/580 Secondary glazing system

Specification data - Aluminium window units

Standard

To BS EN 1474.

Dimensions and configurations

BSI ISO 9001 Kitemark.

Product performance

-

Environmental

-

Background ventilation

-

Manufacturer guidance

Consult manufacturer for details and insert requirements. 

Acoustic performance rating

Up to 49 dB (Rw) reduction dependent on glass and cavity.

Thermal

-

Whole window U-value

As low as 1.5 W/m²K, dependent on glass and primary window make-up.

Frame

-

Profile

Standard.

No subframe version.

Finish as delivered

-

Coating

Powder coating to BS EN 12206-1.

Manufacturer guidance

Variety of stock colours available, plus access to over 200 RAL Colours (charges apply).

Colour

-

Manufacturer guidance

Insert any RAL colour.

Film thickness (minimum)

40 micrometers.

Ventilator

Acoustic trickle vent.

Standard trickle vent.

Glazing or infill

-

Standard

Glazing to BS 6206.

Requirements

-

Manufacturer guidance

Consult manufacturer for details and insert requirements. 

  • 4 mm in the Classic range.
  • 6–10.8 mm in the Enhanced range.

Hardware

Locking push button.

Guidance for specification option:

Available to secure panels (fitted to the interlock sections).

Operation

-

Type

Manual, Left hand orientation.

Manual, Right hand orientation.

Fixing features

-

Manufacturer guidance

Consult manufacturer for details and insert requirements. 


Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recyclability

Fully Recyclable

Third party certifications

CHAS

CHAS

CHAS

Constructionline Gold

Constructionline Gold

Constructionline Gold

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

Literature

Horizontal Sliding Unit - Thermal Simulation Report

Horizontal Sliding Unit - Thermal Simulation Report

Horizontal Sliding Unit - Acoustic Test Results

Horizontal Sliding Unit - Acoustic Test Results

Case studies

Granada Secondary Glazing lowers carbon footprint at Museum of London

Granada Secondary Glazing lowers carbon footprint at Museum of London