Verified by manufacturer 2 months ago
Acoustic separating floor system.
Suitable for use in new build, conversion or refurbishment projects based on concrete structures of approximately 300 kg/m².
Where sound control and insulation is required between separating concrete floors, the Hush HD1010 Hush batten System is particularly suitable.
It is a soundproof ceiling and floor system that has been fully tested and compliant with all UK Building Regulations - Approved Document E (England & Wales), Section 5 (Scotland) and Part G (Northern Ireland).
Representing an economical solution where the building's separating floors are formed from concrete, HD1010 is suitable for use in projects based on concrete structures less than 300 kg/m² down to as low as 235 kg/m² mass per unit area.
How HD1010 is constructed:
Acoustic performance:
Impact (L’nT,w) - 56 dB
Airborne (DnT,w) - 56 dB
Airborne (DnT,w + Ctr) - 47 dB
Features and benefits:
Components:
Color | Brown Grey White |
Finish | Unfinished |
Material | Particleboard Felt Foam Timber |
Shape | Rectangle |
SizeCan be sized to suit the application. | - |
Length | 11000 mm |
Width | 1370 mm |
Height | 10 mm |
Uniclass | |
CAWS | K11/275 Acoustic separating floor system |
Product range |
Linings | - |
Inner layers | Hush Felt Underlay.
|
Fasteners | Hush Bond.Panel adhesive. |
Perimeter seals | Hush Seal 20.
|
Acoustic performance | Impact (Lntw): 56 dB. Airborne (Dntw): 56 dB. Airborne (Dntw +Ctr): 47 dB. |
Battens | Hush Batten 55.
|