NBS Source
I'm a manufacturer

Glidevale Protect FrameFoil FR - A2 Fire Rated Vapour Control Layer

Verified by manufacturer 16 hours ago

BPD Building Product Design Ltd

Class A2 fire retardant, reflective air and vapour control layer (AVCL). Suitable for internal use in steel, masonry and timber construction.

Jump to:
+44 (0)161 905 5700 Website

Application

Suitable for internal use in steel, masonry and timber construction to significantly improve thermal performance and reduce air leakage.

Description

Protect FrameFoil FR is a robust, Class A2 fire retardant, reflective air and vapour control layer (AVCL), offering low emissivity to enhance the thermal performance of walls, ceilings and floors. Suitable for internal use in steel, masonry and timber construction.

FrameFoil FR is independently fire tested in both free hanging and system applications, achieving an A2-s1, d0 reaction to fire classification to exceed current fire regulations.

Offering Class A2 fire rated performance and excellent thermal resistance, this AVCL is complemented by the use of Protect FR Foil tape, which is available separately and manufactured using the same A2 material, giving reassurance on a fire rated system specification. By ensuring membrane overlaps are well sealed, this will also deliver effective airtightness and vapour control to help create a healthier and more energy efficient building.

FrameFoil FR can be combined with the Protect FrameSafe FR or FrameSafe 5000 FR external wall breather membrane to provide a full through-wall system solution, giving optimum defence against the elements during construction and added protection for the life of the building.

* Tested by an external laboratory both free hanging and as part of a system in an end use application with Protect FrameFoil FR fixed over A1 and A2 substrates with a minimum density of 37.5 kg/m3 and all laps sealed using Protect FR Foil tape with a maximum 10% coverage.

Features and benefits:

  • Fully compliant with EN 13501-1 and exceeds requirements in UK Building Regulations Approved Document B & Building.
  • Membrane and tape independently fire tested as a system, providing reassurance in product specification across all building heights.
  • Reflective membrane featuring an advanced glass fibre fabric composition with added tensile strength and durability.
  • Protect FR Foil tape available separately to seal laps for complete system solution.
  • UKCA and CE marked.
  • Ideal for modular, offsite and traditional build on both residential and commercial projects.
  • Strong air and vapour resistance, helping to avoid condensation risk, in accordance with BS 5250.
  • Low emissivity reflective surface achieving an aged thermal resistance of 0.64 m2K/W, enhancing the energy efficiency of the structure when facing into a still air cavity.

General information

Color

Silver

Finish

Reflective

Material

Aluminium

Glass Fibre

Shape

Rectangle

Guidance for specification option:

Supplied as a roll

Length

50000 mm

Width

1200 mm

Height

0.15 mm

Uniclass

Pr_25_57_51_32 Glass fibre membranesPrimary

CAWS

H31/45 Air and vapour control membrane

H31/261 Air and vapour control membrane

H30/261 Air and vapour control membrane

H11/785 Air and vapour control layer

P10/60 Air and vapour control layer

H30/30 Air and vapour control membrane

P10/310 Air and vapour control layer

SKU Code

GVPROFRAMEFOILFR1.2/50

Specification data - Glass fibre membranes

Classification data

Product reference

Glidevale Protect FrameFoil FR.

Weight

165 g/m².

Width (minimum)

1200 mm.

Colour

Silver.

Laminates or surface treatments

Lacquered aluminium foil upper surface.

Purpose

A2 fire rated, low emissivity air and vapour control layer.

Thickness (minimum)

0.15 mm.

Roll length (minimum)

50 m.

Tear resistance

Manufacturer's standard.

Guidance for specification option:

  •  ≥150 N: MD (along roll) - (N) to BS EN 12310-1 with mods.
  •  ≥130: CD (along roll) - (N) to BS EN 12310-1 with mods.

Tensile strength (minimum)

Manufacturer's standard.

Guidance for specification option:

  • ≥700 (N/50 mm): MD (along roll) (after ageing) - (N/50mm) to BS EN 12311-1 with mods.
  • ≥700 (N/50 mm): CD (across roll) (after ageing) - (N/50mm) to BS EN 12311-1 with mods.

Thermal resistance

0.64 m²K/: Aged - heat flow horizontal to BS EN 15976 (incorporates printing).

Guidance for specification option:

  • 0.64 m²K/W: Aged - heat flow horizontal to BS EN 15976 (incorporates printing).
  • 0.45 m²K/: Aged - heat flow vertical to BS EN 15976 (incorporates printing).

Emissivity

0.06 ɛ.

Guidance for specification option:

Unaged; to BS EN 15976.

Manufacturer guidance

Independently tested by a European notified laboratory.

Reaction to fire

To BS EN 13501-1, Class A2-s1, d0.

Guidance for specification option:

Independently fire tested both free hanging and and as part of a system in an end use application fixed over A1 and A2 substrates with a minimum density of 37.5 kg/m3 and all laps sealed using Protect FR Foil tape with a maximum 10% coverage.

Water vapour resistance (minimum)

≥7500 MNs/g / ≥1500 Sd.

Guidance for specification option:

To BS EN 1931.

Resistance to water penetration

Pass - Class W1.

Guidance for specification option:

To BS EN 1928 modified to BS EN 13984.

Accessories

Protect FR Foil tape.

Standard

To BS 5250, BS EN 13501-1, BS EN 15976, BS EN 13984, BS EN 1931, BS EN 1928, BS 9250, BS 13859-2.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Material

Aluminium
Glass Fibre

BIM objects

Platform Compatible Version
Revit
-

1

Literature

BS 5250:2021 Management of moisture in buildings

BS 5250:2021 Management of moisture in buildings

Protect FrameFoil FR - Class A2 Fire Retardant Reflective Air & Vapour Control Layer

Protect FrameFoil FR - Class A2 Fire Retardant Reflective Air & Vapour Control Layer