Glidevale Protect AH6 1 Hour Fire-Rated Hinge-Down Hatch
Application

Suitable for standard 600mm joist centres.

Description

Glidevale loft access hatches have been designed and engineered under BS EN ISO 9001 to meet these latest demands. The AH6 1 hour fire-rated (FR) hinge-down hatch compromise's a door and frame that are formed from 1.0 mm and 1.2 mm Zintec electrogalvanized mild steel finished in polyester powder coating with insulation infill. Closed cell gaskets. Concealed key-operated lock. Option: High-security lock for communal areas.

Features and Benefits:

  • All models meet or exceed the NHBC minimum opening size (NHBC Standards 7.2-D14).
  • Each Glidevale loft access hatch is a complete unit comprising frame and door, with integral closed- cell air/vapour seals and thermal insulation. 
  • The integral seals significantly reduce water vapour migration into the loft space, reducing condensation risk.
  • The seals also virtually eliminate heat loss by air movement around the hatch door.
  • The hatches provide continuity of thermal insulation at ceiling level.
  • 1 hour and 1/2 hour fire resistance options with Class 0 surface flame spread available.
  • Meets or exceeds the NHBC minimum opening size.
  • All Glidevale loft access hatches use insulation which has a Global Warming Potential (GWP) of less than 5 and an Ozone Depletion Potential (ODP) of 0.
  • The AH6 is polyester powder coated in white, which blends unobtrusively with a classic brilliant white ceiling.
  • Meets the minimum U-value requirement of the Approved Documents.

General information

Color

White

Finish

Polyester powder coated

Material

Steel

Zintec electrogalvanized mild 

Shape

Rectangular

Size

540 x 520 mm

Accessible opening size.

647 x 547 mm

Trimmed opening size. (The trimmed opening in the joists should be lined with 6 mm fire-resisting board such as Supalux, therefore the finished trimmed opening size for the AH6 will be 635 x 535 mm.)

Uniclass 2015

Pr_30_59_36_01 Access panelsPrimary

CAWS

L20/630 Hatches

Specification data - Access panels Enhanced data

Fire resistance

60 minutes to BS 476-22.

Reaction to fire classification

Class 0 as defined in Building Regulations Approved Document B.

Position

Ceiling mounted.

Size

647 x 547 mm.

Trimmed opening size. The trimmed opening in the joists should be lined with 6 mm fire-resisting board such as Supalux, therefore the finished trimmed opening size for the AH6 will be 635 x 535 mm.

Frame

Exposed picture frame type.

Panel

-

Material

Steel.

Zintec electrogalvanized mild steel.

Integral finish

Powder coated.

Latch or lock type

Concealed key-operated lock.

Operation

Hinge-down hatch.

Integral accessories

Concealed lock.

Product Reference

AH6 1 Hour Fire-Rated Hinge-Down Hatch

Accessories

High-security key lock.

Clearance dimensions

540 x 520 mm.

Accessible clearance opening (nominal).

U-value

0.35 W/m²K.

Digital objects
Platform Compatible Version Certified to
Revit
-

1

1

Download now from NBS National BIM Library