NBS Source
I'm a manufacturer
Compare variants

Glass Skylight F100 Circular - rooflight

Verified by manufacturer 10 days ago

F100GC-SX-O: Opening for daily ventilation

Lamilux Rooflights Ltd Variant:
Third party certifications:
  • TUV - Safety and Quality Report

    Certificate type

  • EPD

    EPD

    Certificate type

Thermally broken PVC-framed glass circular rooflight on GRP upstand.

Jump to:
01284 749051 Website

Application

Suitable for residential, administrative and office buildings, schools or industrial buildings.

Description

The Glass Skylight F100 is an energy-efficient skylight for rooms with high optical demands. Various shading options can be used to control the amount of light and heat entering the room through the rooflight.


The rooflight is completely pre-assembled on the upstand when delivered to site, and both the ventilated and the fixed variants of the rooflight can be installed on a flat roof immediately.


Glass Skylight F100 Circular Features and benefits:

  • Savings on heating costs and minimized risk of condensation.
  • Optional drive units integrated invisibly in the upstand.
  • Tested watertightness in heavy rain and during storms (impervious to driving rain, in accordance with BS EN 12208, Category E1500, Class 4).
  • Approved fall-through protection according to GS-Bau 18.
  • White, silk-matt appearance inside – no additional drywall construction required.
  • Optional connection to comfort control unit with remote controls.

General information

Color

White

Finish

Glazed

Material

Glass

PVC

Guidance for specification option:

Polyvinyl chloride (PVC).

Glass Reinforced Plastic (GRP)

Shape

Circle

Length

1000 mm

1500 mm

Width

1000 mm

1500 mm

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Product range

Glass rooflights

Specification data - Framed rooflights

Form

Flat.

Size

1000 mm Ø.

Guidance for specification option:

F100GC-S20.

1500 mm Ø.

Guidance for specification option:

F100GC-S21.

Manufacturer guidance

Structural roof opening size. Non-standard sizes are available on request.

Product performance

-

Whole window U-value

1.1 W/m2K.

Frame

-

Material

PVC.

Finish

-

Colour

White (RAL 9016).

Glazing or infill

-

Type

Insulating glass units.

Guidance for specification option:

Double glazed thermal insulating glass to meet CWCT, TN 92 Class 2 fragility. Non-standard glazing options are available on request.

Construction

Double skin.

Guidance for specification option:

6 mm toughened safety glass/ 20 mm cavity/ 9.5 mm laminated safety glass.


Toughened outer, laminated safety glass inner, low emissivity coatings, gas-filled cavities and warm edge spacers. Ug=1.1 W/m²k.

Colour

Clear.

Coating

UV protected.

Manufacturer guidance

Non-standard glazing options are available on request. Consult manufacturer and insert requirements.

Integral kerb

300 mm high fully insulated GRP upstand - factory fitted.

Guidance for specification option:

Non-standard upstand options are available on request.

Operation

-

Type

Powered, electric.

Guidance for specification option:

Opening for daily ventilation via 230 v (un-concealed) chain drive - 300 mm stroke length.

Manufacturer guidance

Non-standard motor options are available on request.

Resistance to wind load

To EN 12210, Class C4.

Guidance for specification option:

Stability against wind and snow loads.

Watertightness

To BS EN 12208, Category E1500, Class 4.

Guidance for specification option:

Watertight to 1500 pascals, representing high winds and driving rain.

Air permeability

Class AE 1050. Assembly airtight (including vents) to Class 4, EN 12207.

Sound insulation

Rwp 38 dB.

Light transmission

80%.

SolarTransmittance

G-Value 0.57.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

Material

Glass

PVC

Guidance for specification option:

Polyvinyl chloride (PVC).

Glass Reinforced Plastic (GRP)

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 50001:2011

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 9001 : 2015

EPD

EPD

EPD - Glass Skylight

Literature

LAMILUX Roofs of Light Brochure

LAMILUX Roofs of Light Brochure

LAMILUX Glass Skylights Brochure

LAMILUX Glass Skylights Brochure

Similar products from Lamilux Rooflights Ltd

Continuous Barrel Vault Rooflight B

Continuous Barrel Vault Rooflight B

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Glass Roof PR60 glazed rooflight - Rooflight / Glass Atrium

Glass Roof PR60 glazed rooflight - Rooflight / Glass Atrium

Glass Roof PR60 Passivhaus Rooflight

Glass Roof PR60 Passivhaus Rooflight

Glass Skylight F100 - rooflight

Glass Skylight F100 - rooflight

Glass Skylight FE 3°  - Rooflight

Glass Skylight FE 3° - Rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight Pyramid / Hipped  - rooflight - Rooflight / Skylight

Glass Skylight Pyramid / Hipped - rooflight - Rooflight / Skylight