NBS Source
I'm a manufacturer
Compare variants

Glass Roof PR60 - Rooflight / Glass Atrium

Verified by manufacturer 15 days ago

Fixed (non opening)

Lamilux Rooflights Ltd Variant:
Third party certifications:
  • TUV - Safety and Quality Report

    Certificate type

  • EPD

    EPD

    Certificate type

A mullion and transom glass roof system for atrium rooflight solutions with optional ventilation.

Jump to:
01284 749051 Website

Application

Suitable for commercial glass roof applications.

Description

The LAMILUX Glass Roof PR60 features virtually free shaping for atrium glass roof designs from pitches as low as 3° - making it possible to implement more or less any aesthetically pleasing and technically complex daylight construction. With trademark features including an attractive design, coupled with the highest level of airtightness and excellent heat-insulation values, the PR60 boasts exceptionally watertight properties, which guarantees no leaks in extremely high winds & driving rain, and effective soundproofing, which reduces the impact of unwanted noise to the interior.


Features and benefits:

  • Flexible shaping to suit individual project needs.
  • Large spanning system which can self-span up to six metres - removing the need for any intermediate steel purlins or support framework.
  • The system can be pitched down to as low as 3° - ideal for any flat roof glass atria rooflight specification.
  • Watertight tested against wind driven rain down to 3° slope with a watertight test result of class RE 1950. This means that right down to the shallowest pitch it will remain completely watertight.
  • Thermally separated structure for maximum energy efficiency.

General information

Color

Other

Finish

Powder-coated

Material

Glass

Aluminium

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary
Pr_30_59_98_03 Aluminium frame roof window units

CAWS

L10/490 Roof ventilators

H10/10 Patent glazing

H10/115 Patent glazing

H11/110 Curtain walling

L10/45 Rooflights

L10/460 Rooflights

Product range

Glass rooflights

Specification data - Framed rooflights

Form

Flat.

Size

As drawing.

Product performance

-

Fire performance

-

Fire resistance

To EN 13830:2003.

Whole window U-value

Guidance for specification option:

Ug approx.1.1 W/m²K; Umt ≤ 1.30 W/m²K. 

Frame

-

Material

Aluminium.

Finish

-

Coating

PPC coated.

Colour

Guidance for specification option:

Can be powder coated any RAL colour; insert requirements. 

Glazing or infill

-

Type

Toughened outer and clear laminated safety glass inner.

Guidance for specification option:

Gas filled cavity and spacer as required to achieve performance required. 

Add any specialist glazing requirements here (i.e. solar control glazing). Ug (glass) = 1.1 W/m²K in the vertical orientation.

Construction

Double skin.

Colour

Clear.

Coating

Low E coating.

Operation

-

Type

Fixed (non opening).

Accessories

None.

Controllable sun protection with exterior blind.

Manufacturer guidance

Non-standard options are available on request.

Execution

Installation to be completed by manufacturer.

Resistance to wind load

Stability against max wind load 2 KN/m² to EN 13830:2003.

Watertightness

To EN 13830:2003, RE 1950 rating.

Guidance for specification option:

Watertight under driving rain.

Air permeability

AE 1950. Assembly airtight (including vents) to EN 13830:2003.

Sound insulation

-

Manufacturer guidance

Varies upon glazing specification. Contact manufacturer for data sheet. 

Light transmission

Guidance for specification option:

Varies upon glazing specification. Contact manufacturer for data sheet. 

SolarTransmittance

Guidance for specification option:

Varies upon glazing specification. Contact manufacturer for data sheet. 

Pitch

As drawing.

Guidance for specification option:

The system can be pitched down to as low as 3° .

Upstand

Complete roof light assembly designed to sit on to pre-weathered perimeter sub-structure (by others) which is to be designed to suit the roof glazing system fixing and loadings requirements.

Standard

To EN 1090-1:2011, EN 13830:2003.

Ventilator

Not required.

Required.

Standard

CWCT Class 1 - Walk-on for cleaning.

CWCT Class 2 - Non-fragile against accidental falls.

CWCT Class 3 - Fragile.

Beading

External, screw.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 50001:2011

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 9001 : 2015

EPD

EPD

EPD - Glass Roof PR60

Literature

BREEAM Profile - Glass Roof

BREEAM Profile - Glass Roof

LAMILUX Glass Roof Brochure

LAMILUX Glass Roof Brochure

LAMILUX Roofs of Light Brochure

LAMILUX Roofs of Light Brochure

Case studies

Shallow 3° glass roof rooflight at Cartwright Gardens

Shallow 3° glass roof rooflight at Cartwright Gardens

Kimpton Fitzroy Hotel, London - rooflight

Kimpton Fitzroy Hotel, London - rooflight

Rooflights installed at Westcliff High School for Girls

Rooflights installed at Westcliff High School for Girls

Sir David Bell Building, Roehampton University - glass skylight

Sir David Bell Building, Roehampton University - glass skylight

Bespoke rooflights installed at Sheffield Hallam University

Bespoke rooflights installed at Sheffield Hallam University

Oundle School Sports Centre - mono-pitch rooflights

Oundle School Sports Centre - mono-pitch rooflights

Similar products from Lamilux Rooflights Ltd

Continuous Barrel Vault Rooflight B

Continuous Barrel Vault Rooflight B

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Glass Roof PR60 Passivhaus

Glass Roof PR60 Passivhaus

Glass Skylight F100 - rooflight

Glass Skylight F100 - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight FE 3°  - Rooflight

Glass Skylight FE 3° - Rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight Pyramid / Hipped  - rooflight - Rooflight / Skylight

Glass Skylight Pyramid / Hipped - rooflight - Rooflight / Skylight