Verified by manufacturer 1 day ago
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
BBA Agrément Certificate
Certificate type
EPD
Certificate type
EPD
Certificate type
Electrically operated, maintenance free, white polyurethane, centre pivot roof window system providing 1.0 m² of smoke-free ventilation area on roof pitches from 15–90°.
Designed to be used on roofs with pitches from 15–90°.
A standard package of components providing a roof window with an automatic smoke ventilation facility.
Features and benefits:
Glazing:
- Code 7040:
Smoke vent:
– SD0L140:
– SD0W140:
Installation products:
Color | White Guidance for specification option: External Colour NCS S-7500-N; Internal Colour, white polyurethane NCS S 0500-N |
Finish | Lacquered Guidance for specification option: Internal frame and sash has a white lacquer finish around a timber core. |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0. |
Width | 1140 mm |
Height | 1178 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items |
Uniclass | |
CAWS | L10/480 Roof windows |
Product range |
Classification data | |
Enclosure | |
Material | Timber. |
Colour | Internal frame and sash have a white lacquer finish around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0. |
Batteries | |
Type | Electrically operated. Guidance for specification option: with Battery Back-up |
Internal frame and sash | White polyurethane. Guidance for specification option: Code 0 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 |
Roof pitch | Guidance for specification option: Insert requirements. |
Smoke vent | GGU SK06 SD0L140. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–90°. GGU SK06 SD0W140. Guidance for specification option: For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. |
Installation products | Not required. Insulation Collar – Code BDX 2000. Guidance for specification option: Includes BFX. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. Wind deflector – Code KFD 0000. Guidance for specification option: For compliance with aerodynamic smoke ventilation requirements. |
Contains Red List materials | No |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0. |
Recyclability | Partially Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % |
Expected Life | 25 year |