NBS Source
List your products

GGU INTEGRA® solar powered, white polyurethane, centre-pivot roof window, twin installation

Third party certifications:
  • BBA Agrément Certificate

    Certificate type

  • QA Certificate

    Certificate type

VELUX Company Ltd

Fully integrated, solar powered, maintenance free, white polyurethane, centre pivot roof windows, for twin installation with 18 mm or 50 mm gap on roof pitches between 15–90°.

Jump to:
+44 (0)1592 778225 www.velux.co.uk
Description

Fully integrated, solar powered, maintenance free, white polyurethane, centre pivot roof windows, for twin installation with 18 mm or 50 mm gap on roof pitches between 15–90°.

Features:

  • Maintenance free polyurethane moulding with white finish on timber core.
  • Fully integrated, pre-installed motor.
  • Photovoltaic cell on the external window frame charges the battery which in turn powers the motor for operation; PV cell requires direct exposure to sunlight.
  • No need to plug into a power supply.
  • Ideal for out-of-reach areas.

Operation:

  • Simple, convenient wall switch to operate the windows.
  • Rain sensor closes window automatically in the event of rain.

Warranty:

  • Ten-year guarantee for windows and panes.
  • Three-year guarantee for electrical items and blinds.

General information
Features

Maintenance free polyurethane moulding with white finish on timber core

Fully integrated, pre-installed motor

Photovoltaic cell on the external window frame charges the battery which in turn powers the motor for operation; PV cell requires direct exposure to sunlight

No need to plug into a power supply

Ideal for out-of-reach areas

Uniclass 2015
Rigid polyurethane frame roof window units (Pr_30_59_98_72)Primary
Specification data - Rigid polyurethane frame roof window units
Product Reference

GGU INTEGRA® solar powered, white polyurethane, centre-pivot roof window, twin installation

Roof pitch

Insert requirements.

Number of windows in group

Insert requirements.

Distance between side frames

18 mm

Standard frame gap.

50 mm

Codes CK02, CK04 and CK06 only.

Support rafters

Not required

EBY W20 2000

2000 mm long.

EBY W27 2000

2700 mm long.

EBY W35 2000

3500 mm long.

Window -
Window code

GGU CK02

Standard size 550 mm wide x 778 mm high, effective daylight area 0.22 m².

GGU CK04

Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m².

GGU CK06

Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m².

GGU FK06

Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m².

GGU MK04

Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m².

GGU MK06

Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m².

GGU MK08

Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m².

GGU PK08

Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m².

GGU PK10

Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m².

GGU SK06

Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m².

GGU UK04

Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m².

GGU UK08

Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m².

GGU FK04

Non-standard size 660 mm wide x 978 mm high, effective daylight area 0.38 m².

GGU FK08

Non-standard size 660 mm wide x 1398 mm high, effective daylight area 0.58 m².

GGU MK10

Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.85 m².

GGU PK06

Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m².

GGU SK08

Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m².

Finish -
Internal frame and sash

White polyurethane lacquer – Code 0

External cladding

Grey aluminium; colour reference NCS S-7500-N - Code 0

Untreated copper – Code 1

Titanium zinc – Code 3

Painted aluminium – Code 8, colour

Insert RAL or NCS colour reference.

Glazing

6830

6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings.

6630

6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.

7030

6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.

Blinds, Awning and Shutter -
Type

Not required

Blackout blind – code DSL

External awning blind – code MSL

External shutter – code SSL

Light dimming energy blind – code FSC

Pleated blind – code FSL

Colour

Not applicable

As schedule

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Energy efficient installation

Insulation Collar – Code BDX 2011

Includes BFX, for 18 mm gap only.

Underfelt Collar – Code BFX 1000

Vapour Barrier Collar – Code BBX 0000

Flashing

EBL 0021B

18 mm gap between units; for standard installation into slate up to 8 mm thick; roof pitch 15–90º.

EBW 0021B

18 mm gap between units; for standard installation into tiles up to 120 mm in profile; roof pitch 15–90º.

EBP 0021B

18 mm gap between units; for standard installation into plain tiles up to 14 mm thick; roof pitch 25–90º.

EBL 0021C

50 mm gap between units; for standard installation into slate up to 8 mm thick; roof pitch 15–90°; CK02, CK04 and CK06 only.

EBW 0021C

50 mm gap between units; for standard installation into tiles up to 120 mm in profile; roof pitch 15–90º; CK02, CK04 and CK06 only.

ZWC

For standard installation where an on-site flashing is required; roof pitch 15–90°.

Accessories

None

VELUX ACTIVE with NETATMO – Code KIX 300

Smart sensor based operation and smartphone control.

Standard product features

Support rafters:

Supplied in the same finish as the roof windows.

Internal finish:

White lacquer finish on moulded polyurethane around a timber core.

Product Options

Glazing:

- Code 6830:

  • Thermal performance (U-value): 1.1 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 6630:

  • Thermal performance (U-value): 1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 7030:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

Energy efficiency installation collars:

  • Insulation collar – Code BDX 2011: Optimizes the insulation around the window frame by preventing heat loss and eliminating cold bridges. Includes underfelt collar BFX.
  • Underfelt collar – Code BFX: Ensures a weathertight seal between the roof window and the roof.
  • Vapour barrier collar – Code BBX: Provides vapour control and air permeability seal.

Flashing:

Flashings are available in materials and finishes to match roof window cladding.

- Code EBL 0021B:

  • For standard installation into slate and flat roofing materials up to 8 mm thick: not suitable for interlocking slate.
  • 18 mm gap between units.
  • Roof pitch 15–90º.

- Code EBW 0021B:

  • For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates.
  • 18 mm gap between units.
  • Roof pitch 15–90º.

- Code EBP 0021B:

  • For standard installation into plain tiles up to 14 mm thick.
  • 18 mm gap between units.
  • Roof pitch 25–90º.

- Code EBL 0021C:

For CK02, CK04 and CK06 size windows only.

  • For standard installation into slate and flat roofing materials up to 8 mm thick: not suitable for interlocking slate.
  • 50 mm gap between units.
  • Roof pitch 15–90º.

- Code EBW 0021C:

For CK02, CK04 and CK06 size windows only.

  • For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates.
  • 50 mm gap between units.
  • Roof pitch 15–90º.

- Code ZWC:

  • Window profile set to be used in conjunction with on-site weathering for non-standard roofing materials.
  • Roof pitch 15–90º.
  • For further details please contact VELUX.

Third party certifications

Additional certifications:

  • CE Marked: EN 14351-1:2006 + A2:2016
Similar products from VELUX Company Ltd