NBS Source
List your products

GGU INTEGRA® electric, white polyurethane, centre-pivot roof window with GIU sloping fixed window below

Third party certifications:
  • QA Certificate

    Certificate type

VELUX Company Ltd

Electrically operated, maintenance free, white polyurethane, centre pivot roof window with additional lower fixed element on roof pitches between 15–90°.

Jump to:
+44 (0)1592 778225 www.velux.co.uk
Description

Electrically operated, maintenance free, white polyurethane, centre pivot roof window with additional lower fixed element on roof pitches between 15–90°.

Fixed elements are installed in combination side by side to create panoramic views. The fixed window is installed directly below the roof window.

Ventilation, exterior maintenance and cleaning is via the roof window.

Features:

  • Maintenance free polyurethane moulding with white finish on timber core.
  • Fully integrated. pre-installed motor.
  • Ideal for out-of-reach areas.
  • Additional fixed element beneath offers a great view while standing and when seated.

Operation:

  • Simple, convenient wall switch to operate the upper window.
  • Rain sensor closes the upper window automatically in the event of rain.

Warranty:

  • Ten-year guarantee for windows and panes.
  • Three-year guarantee for electrical items and blinds.

General information
Features

Maintenance free polyurethane moulding with white finish on timber core

Fully integrated. pre-installed motor

Ideal for out-of-reach areas

Additional fixed element beneath offers a great view while standing and when seated

Uniclass 2015
Rigid polyurethane frame roof window units (Pr_30_59_98_72)Primary
Specification data - Rigid polyurethane frame roof window units
Product Reference

GGU INTEGRA® electric, white polyurethane, centre-pivot roof window with GIU sloping fixed window below

Roof pitch

Insert requirements.

Window -
Roof window code

GGU MK04

Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m².

GGU MK06

Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m².

GGU MK08

Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m².

GGU PK08

Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m².

GGU PK10

Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m².

GGU SK06

Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m².

GGU UK04

Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m².

GGU UK08

Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m².

GGU MK10

Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.85 m².

GGU PK06

Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m².

GGU SK08

Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m².

Fixed lower window code

GIU MK34

Standard size 780 mm wide x 920 mm high; effective daylight area 0.44 m².

GIU PK34

Standard size 942 mm wide x 920 mm high; effective daylight area 0.56 m².

GIU SK34

Non-standard size 1140 mm wide x 920 mm high; effective daylight area 0.70 m².

GIU UK34

Non-standard size 1340 mm wide x 920 mm high; effective daylight area 0.85 m².

Finish -
Internal frame and sash

White polyurethane – Code 0

External cladding

Grey aluminium; colour reference NCS S-7500-N - Code 0

Untreated copper – Code 1

Titanium zinc – Code 3

Painted aluminium – Code 8

Insert RAL or NCS colour reference.

Glazing -
Upper roof window

6821U

6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings.

6621U

6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.

7021U

6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4mm toughened outer pane.

Lower fixed window

68

6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings.

66

6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.

70

6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.

Blind -
Upper roof window

Not required

Blackout blind – Code DML

Light dimming energy blind – Code FMC

Pleated blind – Code FML

Roller blind – Code RML

Colour

Not applicable

As schedule ___

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Lower fixed window

Not required

Blackout blind – Code DML

Requires KUX 100 Control unit

Light dimming energy blind – Code FMC

Requires KUX 100 Control unit

Pleated blind – Code FML

Requires KUX 100 Control unit

Roller blind – Code RML

Requires KUX 100 Control unit

Colour

Not applicable

As centre-pivot

As schedule ___

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Energy efficient installation

Insulation Collar – Code BDX 2000

Not compatible with E*N and E*J flashings. Includes BFX.

Underfelt Collar– Code BFX 1000

Vapour Barrier Collar – Code BBX 0000

Flashing

EDL + ETL

For standard installation into slate up to 8 mm thick; root pitch 15–90°

EDW + ETW

For standard installation into tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting.

EDN + ETN

For recessed installation into slate up to 8 mm thick; root pitch 20–90°.

EDJ + ETJ

For recessed installation into tile up to 120 mm thick; root pitch 20–90°.

ZWC

For standard installation where an on-site flashing is required; roof pitch 15–90°.

Accessories

None

VELUX ACTIVE with NETATMO –Code KIX 300

Smart sensor based operation and smartphone control. Upper roof windows only.

Battery Back-Up – Code KLB 100

Upper roof windows only.

Product Options

Glazing:

- Upper roof window:

- Code 6821U:

  • Thermal performance (U-value): 1.1 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 6621U:

  • Thermal performance (U-value): 1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 7021U:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

- Lower fixed window:

- Code 68:

  • Thermal performance (U-value): 1.1 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 66:

  • Thermal performance (U-value): 1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.51.

- Code 70:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

Configuration:

Roof window and lower fixed window must be the same width.

Flashing:

Flashings are available in materials and finishes to match roof window cladding.

  • Code EDL + ETL: For standard installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15–90°.
  • Code EDW + ETW: For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates. Roof pitches from 15–90°.
  • Code EDN + ETN: For recessed installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15–90°.
  • Code EDJ + ETJ: For recessed installation into flat and profiled roof materials up to 90 mm thick, including profiled sheeting and interlocking slates; Roof pitches from 20–90°.
  • Code ZWC: Window profile set to be used in conjunction with on-site weathering for non-standard roofing materials. For further details please contact VELUX.

Third party certifications
  • CE marked: EN 14351-1:2006 + A2:2016
Similar products from VELUX Company Ltd