QA Certificate
Certificate type
Electrically operated, maintenance free, white polyurethane, centre pivot roof window with additional lower fixed element for combination installations on roof pitches between 15–90°.
Electrically operated, maintenance free, white polyurethane, centre pivot roof window with additional lower fixed element for combination installations on roof pitches between 15–90°.
Fixed elements are installed in combination side by side to create panoramic views. The fixed window is installed directly below the roof window.
Combination flashings are modular meaning there is no limit to the overall size of the group, but the minimum distance between windows side by side is 100 mm.
Ventilation, exterior maintenance and cleaning is all via the roof window.
Features:
Operation:
Warranty:
Features | Maintenance free polyurethane moulding with white finish on timber core Fully integrated. pre-installed motor Ideal for out-of-reach areas Additional fixed elements beneath offer a great view while standing and when seated |
Uniclass 2015 | |
CAWS | L10/480 Roof windows L10/50 Roof windows |
Product Reference | GGU INTEGRA® electric, white polyurethane, centre-pivot roof window with GIU sloping fixed windows below, combination installation |
Roof pitch | Insert requirements. |
Number of roof windows | Insert requirements. |
Number of fixed lights | Insert requirements. |
Distance between side frames | 100 mmStandard frame gap. 120 mm140 mm160 mm |
Window | - |
Roof window code | GGU MK04Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². GGU MK06Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m². GGU MK08Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m². GGU PK08Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m². GGU PK10Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m². GGU SK06Standard size 1140 mm wide x 1178 mm high, effective daylight area 0.95 m². GGU UK04Standard size 1340 mm wide x 978 mm high, effective daylight area 0.91 m². GGU UK08Standard size 1340 mm wide x 1398 mm high, effective daylight area 1.40 m². GGU MK10Non-standard size 780 mm wide x 1600 mm high, effective daylight area 0.85 m². GGU PK06Non-standard size 942 mm wide x 1178 mm high, effective daylight area 0.75 m². GGU SK08Non-standard size 1140 mm wide x 1398 mm high, effective daylight area 1.16 m². |
Fixed lower window code | GIU MK34Standard size 780 mm wide x 920 mm high; effective daylight area 0.44 m². GIU PK34Standard size 942 mm wide x 920 mm high; effective daylight area 0.56 m². GIU SK34Non-standard size 1140 mm wide x 920 mm high; effective daylight area 0.70 m². GIU UK34Non-standard size 1340 mm wide x 920 mm high; effective daylight area 0.85 m². |
Finish | - |
Internal frame and sash | White polyurethane – Code 0 |
External cladding | Grey aluminium; colour reference NCS S-7500-N - Code 0Untreated copper – Code 1Titanium zinc – Code 3Painted aluminium – Code 8Insert RAL or NCS colour reference. |
Glazing | - |
Upper roof window | 6821U6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 6621U6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 7021U6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. |
Lower fixed window | 686.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 666.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 706.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. |
Blind | - |
Upper roof window | Not requiredBlackout blind – Code DMLLight dimming energy blind – Code FMCPleated blind – Code FMLRoller blind – Code RML |
Colour | Not applicableAs schedule ___Refer to VELUX Blinds and Shutters brochure for available colours and patterns. |
Lower fixed window | Not requiredBlackout blind – Code DMLRequires KUX 100 Control unit. Light dimming energy blind – Code FMCRequires KUX 100 Control unit. Pleated blind – Code FMLRequires KUX 100 Control unit. Roller blind – Code RMLRequires KUX 100 Control unit. |
Colour | Not applicableAs centre-pivotAs schedule ___Refer to VELUX Blinds and Shutters brochure for available colours and patterns. |
Energy efficient installation | Insulation Collar – Code BDX 2000Not compatible with E*N and E*J flashings. Includes BFX. Underfelt Collar – Code BFX 1000Vapour Barrier Collar – Code BBX 0000 |
Flashing | EKL + ETLFor standard installation into slate up to 8 mm thick; root pitch 15–90° EKW + ETWFor standard installation into tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EKN + ETNFor recessed installation into slate up to 8 mm thick; root pitch 20–90°. EKJ + ETJFor recessed installation into tile up to 120 mm thick; root pitch 20–90°. ZWCFor standard installation where an on-site flashing is required; roof pitch 15–90°. |
Other requirements | NoneVELUX ACTIVE with NETATMO - Code KIX 300Smart sensor based operation and smartphone control. Upper roof windows only. Battery Back-Up – Code KLB 100Upper roof windows only. |
Product Options | Glazing: Upper roof window: - Code 6821U:
- Code 6621U:
- Code 7021U:
- Lower fixed window: - Code 68:
- Code 66:
- Code 70:
Configuration: The number of roof windows must be the same as the number of lower fixed windows; roof windows and lower fixed windows must be the same width. Flashing: Flashings are available in materials and finishes to match roof window cladding.
|
CFP Fixed flat roof window
CFP Fixed flat roof window, curved glass
CFP Fixed flat roof window, flat glass
CSP Flat roof smoke ventilation window
CVP INTEGRA® Elect. flat roof window
CVP INTEGRA® Elect. flat roof window, curved glass
CVP INTEGRA® Elect. flat roof window, flat glass
CXP Flat roof exit window
ECX insulated flat roof kerb
GDL CABRIO® Balcony