Loose laid gas membrane.
Loose laid sheet membrane system designed to protect buildings against the ingress of methane, radon, carbon dioxide, hydrocarbon vapours and water vapour. The multi-layered laminate structure gives good strength, flexibility and installation properties. The upper surface of the membrane is coloured green.
Features and benefits:
Shape | Circular Roll |
MaterialHigh performance, reinforced polyethylene membrane incorporating a gas resistant aluminium foil. | Polyethylene Aluminium |
Size | 2 x 50 m |
Uniclass | |
CAWS | J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/145 Loose-laid weldable polyethylene gas-retardant membranes |
Material | High-density polyethylene (PE-HD). |
Purpose | Gas retardance and water resistance. |
Performance characteristics | - |
Tensile strength (minimum) | >9 kN/m. |
Tear resistance | >350 N. |
Resistant to underground gases | Carbon dioxide / Methane / Radon. |
Root inhibitor | Aluminium foil. |
Physical properties | - |
Weight (minimum) | 360 g/m². |
Dimensions | - |
Thickness (minimum) | 0.4 mm. |
Width (minimum) | 2 m. |
Roll length (minimum) | 50 m. |
Product Reference | GGM 400 Gas Membrane |
Moisture vapour transmission rate | <0.03 g/m²/day. |
Radon transmittance | <1x10-9 m/s. |
Methane transmission rate | <0.005 ml/m²/h/atm. |
Platform | Compatible | Version | Certified to |
---|---|---|---|
![]() | - | 1 | 2.1 |
![]() | - | 1 | 2.1 |