NBS Source
I'm a manufacturer

Frameless Glass Links

Verified by manufacturer 1 month ago

Precision Glass Ltd

Frameless glass linkways designed to provide shelter between structures.

Jump to:
+44 (0) 1444 717317 Website

Application

Suitable to link structures, commonly used in barn conversions and oast houses, where historic interest and conservation is of concern.

Description

Frameless glass links are used to link two buildings together in a modern yet unobtrusive way. Commonly used in barn conversions and oast houses, where historic interest and conservation is of concern, a glass link uses structural glass to create a habitable passage between new and old without detracting from the original intent of the building.


Typically double glazed, structural glass links can integrate a host of features such as switchable privacy glass, heated glass and solar PV glass.


Features and benefits:

  • Minimal appearance.
  • Typically double glazed.
  • Optional features.
  • Multiple hardware finishes.
  • Walls: 34 mm double glazed, stepped edge, unit with argon gas and Low-E coating.
  • Roofs: 37.5 mm double glazed, stepped edge, unit with argon gas and Low-E coating.
  • Maximum panel size up to 6 metres.


Complies with:

  • BS EN 12600:2002 (supersedes BS 6206: 1981).
  • BS EN 1991-1-1.
  • BS EN 12150-1:2015.
  • BS 6262-4:2018.
  • BS 6399-1:1996.
  • Approved Document K.

General information

Color

Clear

Bronze

Grey

Finish

Glazed

Material

Glass

Aluminium

Stainless steel

Shape

Rectangle

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

One year

Material

Glass

Aluminium

Stainless steel

Uniclass

Pr_25_71_33_35 Glass panelsPrimary

CAWS

H13/630 Laminated glass

H13/610 Glass generally

L40/195 Glass-to-glass jointing – proprietary

H10/30 Glass

Specification data - Glass panels

Standards

-

Route-marking barriers

To BS 6262-4.

Protective barriers

To BS 6262-4.

Framed laminated glass and laminated safety glass

To BS EN 12600.

Impact resistance

To BS EN 12600.

Panel type

Single glazed glass panels.

Double glazed glass panels.

Insulated units.

Panel dimensions

-

Width

-

Manufacturer guidance

  • Project specific.
  • Maximum panel size up to 6 m depending on glass specification.
  • Consult manufacturer and insert requirements.

Height

-

Manufacturer guidance

  • Project specific.
  • Maximum panel size up to 6 m depending on glass specification.
  • Consult manufacturer and insert requirements.

Frame

-

Material

Aluminium.

Stainless steel.

Finish as delivered

-

Applied finish

Satin stainless steel.

Guidance for specification option:

For stainless steel.

Powder coating.

Guidance for specification option:

For aluminium.

Glass infill

-

Material

Structural glass.

Guidance for specification option:

Argon gas and Low-E coating.

Thickness

34 mm.

Guidance for specification option:

Walls.

37.5 mm.

Guidance for specification option:

Roofs.

Tint

Clear.

Body tinted.

Colour

Not required.

Guidance for specification option:

For 'Clear' tint.

Bronze.

Guidance for specification option:

For 'body tinted'.

Grey.

Guidance for specification option:

For 'body tinted'.

Finish as delivered

-

Worked finish

None.

Sand blasted.

Edges

Stepped edge.

Accessories

Not required.

Switchable interlayer.

Glazing options

Not required.

Laminated glass.

Guidance for specification option:

Included for any roof panels and critical load walls and optional for extra security walls.

Solar control glass.

Low iron glass.

Anti-reflective glass.

Show more

Manufacturer guidance

Consult manufacturer for details.

Doors

Not required.

Single door.

Double door.

Manufacturer guidance

  • Doors are currently untested as external doors.
  • Consult manufacturer for details.

Lock

Not required.

Integrated into lever latch handle.

Integrated into Guardsman type handle (full height).

Shootbolts (top and bottom).

Manufacturer guidance

Door lock options.

Fixing options

Thermally broken extruded aluminium profiles.

Back to back angles, stainless steel.

Back to back angles, aluminium.

Bespoke channel, stainless steel.

Bespoke channel, aluminium.

Manufacturer guidance

  • Framework/ supporting structure to attach the glass link to the existing building and base.
  • All glass to glass joints are frameless, structurally bonded joints.
  • Suitability of each fixing option will be project specific.
  • For non-thermally broken methods, framing detail will need to be addressed within architect’s design to prevent cold bridging.

Waterproofing

-

Manufacturer guidance

Waterproofing options available.

Consult manufacturer for details and insert requirements or omit.

Finish as delivered

Stainless steel.

Powder-coated, standard RAL colour.

Powder-coated, custom colour.

Manufacturer guidance

Hardware finish.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Material

Glass

Aluminium

Stainless steel

Recyclability

Fully recycleable

Expected Life

Ten year

Literature

Frameless Glass Links

Frameless Glass Links