FireStop Ei30 Double Glazed Partition System

Application

All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.

Description

Double glazed fire rated steel framed partition system.


Features and benefits:

  • The FireStop glazed partitioning and door range achieves up to Ei30 (integrity + insulation) on fixed screens and up to Ei30 on doors. Utilizing robust thermally broken and insulated steel profiles it offers extreme levels of fire protection for even the most stringent of fire requirements, making it suitable for even the most demanding of applications.
  • Also available in Ei60 single glazed format or Ei60 (single or double glazed). All specified separately.


Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Finish

PPC

Polyester powder-coated.

Color

Other

Any RAL code.

Material

Steel

Glass

Shape

To suit project requirements; consult manufacturer for further details.

-

Size

To suit project requirements; consult manufacturer for further details.

-

WarrantyDescription

Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details.

-

Uniclass 2015

Pr_25_71_57_60 Partition panelsPrimary
Ss_25_12_65_65 Panel partition systems

CAWS

K30/130 Relocatable partition system

K30/10 Relocatable partition system

Specification data - Partition panels Enhanced data

Third party accreditation

ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.

EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more).

Unit size

-

Thickness

98 mm.

110 mm.

Partition height (nominal)

Consult with manufacturer to ensure compliance with certification.


-

Width (nominal)

Consult with manufacturer to ensure compliance with certification.


-

Deflection allowance (maximum)

-

Head

Excluding deflection, excluding blinds - 60 mm-deep x 98-mm wide steel insulated channel.

Excluding deflection, incuding blinds -60 mm-deep x 110-mm wide steel insulated channel.

±25 mm deflection, excluding blinds -112 mm-deep x 131 mm-wide steel insulated two-part channel.

±25 mm deflection, including blinds -112 mm-deep x 145 mm-wide steel insulated two-part channel.

Floor

Consult with manufacturer for system weight.


-

Verticals

Corners: glass-to-glass joints.

Excluding blinds - 60 mm-deep x 98 mm-wide steel insulated channel.

Including blinds - 60 mm-deep x 110 mm-wide steel insulated channel.

Panel partition type

Frameless glass - double glazed.

Framing, junctions, corners

As Verticals.

Joint treatment

-

Type

Butt jointed glazing; double glazed, fire-rated silicone joints.

Consult with manufacturer to ensure compliance with test/assessment data.


  • Primary fire rated glazing (17 mm): fire rated silicone.
  • Secondary sacrificial glazing: (10-21.5 mm).
  • Vertex PVC translucent cross dry joint, (1.5 mm visible, glass edge prep required).
  • Linea PET-G translucent or black dry joint (5 mm visible, glass edge prep required).
  • Nova SAA / PPC aluminium dry joint (13 mm visible, glass edge prep required).
  • Solar PVC-U translucent ‘H’ joint (12 mm visible).
  • Acrylic glazing tape, translucent (2 mm visible).


Finish and colour

Coloured silicone.

Consult manufacturer and insert requirements.

Glazed panels

-

Type

Primary fire rated glazing: 17 mm annealed multi-laminate fire glass; Secondary sacrificial glazing: (10-21.5 mm)/

Integral blinds

Tilt / turn manual venetian blinds with blind control knob (fire risk side only).

Two panels maximum.

Tilt / turn battery powered venetian blinds, remote control operation.

One white sensor battery pack per blind.

Not required.

Door arrangement

-

Type

Consult with manufacturer for details and insert requirements.


-

Door frames

Consult with manufacturer for details and insert requirements.


-

Door leafs

-

Type

Consult with manufacturer for details and insert requirements.


-

Ceiling

-

Type

Consult manufacturer for interface detail and insert requirements.


-

Method of support

Consult manufacturer for support detail and insert requirements.


-

Perimeters, skirtings, sills

Corners: glass-to-glass joints.

Excluding blinds - 60 mm-deep x 98 mm-wide steel insulated channel.

Including blinds - 60 mm-deep x 110 mm-wide steel insulated channel.

Hardware

Consult manufacturer and insert requirements.


-

Seals

Primary fire glass: intumescent silicone.

Other features

Consult manufacturer and insert requirements or leave blank.


-

Product Reference

FireStop Ei30 Double Glazed Partition System

Manifestation

To architects choice and in accordance with the requirements of Approved Document K.


Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost.

Insert requirements.


Artwork and custom manifestation to client design.

Insert requirements.


StrengthGrade

Consult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm.


For glass load resistance criteria;

  • BS 5234 not applied to “all glass partition screens”.
  • Nominal line load criteria of “short-term impact load” utilised.
  • 0.36 kN/m applied as linear load at 1100 mm above FFL.
  • Glass deflection limited to L/65 or 25 mm, whichever is less under load.
  • Maximum deflection and stress in accordance with the glass performance requirements of EN 572/ EN 12150/ EN 12543/ EN 14179 (where heat soaked).


Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:

  • 0.36 kN/m (default load).
  • 0.74 kN/m.
  • 1.5 kN/m.


BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm.

Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings).

Structural glass based on line-load and attendant UDL + point load, insert as required:

  • 0.74 kN/m.
  • 1.5 kN/m.
  • 3.0 kN/m.


-

Acoustic performance

46 dB Rw.

Excluding blinds,

49 dB Rw.

Including blinds,

Fire insulation

Ei30 (30/30 integrity and insulation).

Partition

Frameless glass - double glazed.

Fasteners

To manufacturer's specification, type, length and frequency to suit substrates.

Joint treatment

Butt jointed glazing.

Samples required

Consult with manufacturer.


-

Environmental information

Contains Red List materials

No

No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product.

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

100%

Steel and glass.

Recycled content

17–28% for glass.

15–20% for steel.

-

Digital objects

Platform Compatible Version Certified to
Revit

Revit 2017

1

2.0
Download now from NBS National BIM Library

Literature

FireStop - Images & Information

FireStop - Images & Information

Planet Partitioning Product Guide

Planet Partitioning Product Guide

Similar products from Planet

Fire-Eco Ei30 Double Glazed Partition System

Fire-Eco Ei30 Double Glazed Partition System

Fire-Eco Ei30 Single Glazed Partition System

Fire-Eco Ei30 Single Glazed Partition System

Fire-Eco Ei60 Double Glazed Partition System

Fire-Eco Ei60 Double Glazed Partition System

Fire-Eco Ei60 Single Glazed Partition System

Fire-Eco Ei60 Single Glazed Partition System

FireClear100 Double  Glazed Partition System

FireClear100 Double Glazed Partition System

FireClear20  Single Glazed Partition System

FireClear20 Single Glazed Partition System

FireClear54 Double Glazed Partition System

FireClear54 Double Glazed Partition System

FirePro E120 Single Glazed Partition System and Ei 60 Doorset

FirePro E120 Single Glazed Partition System and Ei 60 Doorset

FirePro E30 Double Glazed Partition System and Doorset

FirePro E30 Double Glazed Partition System and Doorset

FirePro E30 Single Glazed Partition System and Doorset

FirePro E30 Single Glazed Partition System and Doorset