Verified by manufacturer 4 months ago
Frameless glazed elevations achieving E30 fire rating.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.
Frameless glazed elevations achieving E30 fire rating.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for our products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Polyester powder-coated or anodized. Silver Polished and linished. |
Finish | Polished Anodized Etched and anodized. Powder-coated |
Material | Aluminium 6063 T6. Glass |
ShapeBespoke, to suit project requirements; consult manufacturer for further details. | - |
Width | Bespoke |
Height | Bespoke |
Warranty description | Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Third party accreditation | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | - |
Thickness | 27 mm.30 mm.For deep head. |
Partition height (nominal)Consult with manufacturer to ensure compliance with certification. | - |
Width (nominal)Consult with manufacturer to ensure compliance with certification. | - |
Deflection allowance (maximum) | - |
Head | No deflection, 50 mm deep x 27 mm wide channel.±15 mm deflection, 30 x 103 mm channel. |
FloorConsult with manufacturer for system weight. | - |
Verticals | 27 mm deep x 27 mm wide channel.50 mm deep x 27 mm wide channel. |
Panel partition type | Frameless glass - centre glazed. |
Framing, junctions, cornersCorners: glass-to-glass joints. | 27 mm deep x 27 mm wide base/ abutment track.Corners: glass to glass joints. 50 mm deep x 27 mm wide base/ abutment track.
|
Joint treatment | - |
Type | Butt jointed glazing; Single centre glazed, fire-rated silicone joints.Consult with manufacturer to ensure compliance with test/ assessment data. |
Finish and colour | Coloured silicone.Consult manufacturer for options and insert requirements. |
Glazed panels | - |
Type | Single centre glazed, 17 mm fire-rated annealed laminate.Consult with manufacturer to ensure compliance with test/ assessment data. |
Integral blinds | n/a.Not suitable for this system. |
Door arrangement | - |
Type | 12 mm-thick FireClear frameless leaf into A104 doorframe, single leaf single action, separated from glazed screens by separation post.Consult with manufacturer for details. |
Door frames | Planet K534 aluminium doorframe, with single leaf set. |
Door leafs | - |
Type | Planet FireClear 12mm door leaf – non acoustic.Planet FireClear 12mm door leaf – 34 dB Rw. |
Ceiling | - |
TypeConsult manufacturer for interface detail and insert requirements. | - |
Method of supportConsult manufacturer for support detail and insert requirements. | - |
Perimeters, skirtings, sills | 27 mm or 50 mm deep x 20 mm wide aluminium channel.To match Framing. junctions. corners. |
HardwareInsert requirements:
| - |
Seals | Intumescent silicone. |
Other featuresConsult manufacturer and insert requirements or leave blank. | - |
ManifestationTo architects choice and in accordance with the requirements of Approved Document K. | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Insert requirements. Artwork and custom manifestation to client design. Insert requirements. |
StrengthGradeConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
| - |
Acoustic performance | 38 dB Rw. |
Fire performance | E30 (30/0) integrity only. |
Partition | Frameless glass - single centre glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Butt jointed glazing. |
Samples requiredConsult with manufacturer. | - |
Contains Red List materials | No No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 100% Up to 100% for aluminium and glass. |
Recycled content | % 17–28% for glass; 70% for aluminium. |
FireClear100 Double Glazed Partition System
FireClear54 Double Glazed Partition System
FireEco Ei30 Double Glazed Partition System
FireEco Ei30 Single Glazed Partition System
FireEco Ei60 Double Glazed Partition System
FireEco Ei60 Single Glazed Partition System
FirePro E120 Single Glazed Partition System And Ei 60 Doorset
FirePro E30 Double Glazed Partition System And Doorset
FirePro E30 Single Glazed Partition System and Doorset
FirePro E60 Double Glazed Partition System and Doorset