Fire-teK Beam and Column Slab is a Rock Mineral Wool Slab used in the fire protection of structural steel and cast iron beams and columns.
Fire-teK Beam and Column Slab is a Rock Mineral Wool Slab used in the fire protection of structural steel and cast iron beams and columns.
Fire-teK Beam and Column Slab is used to provide fire protection to structural steel columns, beams and trusses. Fire-teK Beam and Column Slab with a foil facing are suitable for use above clean rooms, within air plenums, or for aesthetic purposes. Plaster manufacturers advice and guidance should be followed regarding pre-treatment of Fire-teK Beam and Column Slabs before application of plaster finishes. Fire-teK Beam and Column Slab can be used with four types of fixing systems for the fire protection of structural steelwork. Fixing systems:
Fire-teK Beam and Column Slab is a Rock Mineral Wool Slab used in the fire protection of structural steel and cast iron beams and columns.
They are non-combustible with the best possible Euroclass A1 reaction to fire classification, and are available either unfaced, or with a foil facing.
Features and benefits:
Certification:
Durability:
Fire-teK Beam and Column Slab is odourless, rot proof, non-hygroscopic, does not sustain vermin and will not encourage the growth of fungi, mould or bacteria.
Standards and certification:
Fire-teK Beam and Column Slab is manufactured in accordance with BS EN 13162, ISO 50001 Energy Management Systems, ISO 14001 Environmental Management Systems, and ISO 9001 Quality Management Systems, as certified by TÜV Nord.
Real performance:
Glass and Rock Mineral Wool are easier to install correctly than other insulants such as rigid boards because they adapt to any slight imperfections in the substrate and knit together, eliminating any air gaps. Evidence shows the absence of air gaps is crucial to achieving real performance in the relevant application.
Environmental:
Fire-teK Beam and Column Slab contains no ozone-depleting substances or greenhouse gases. For further environmental information consult the relevant Environmental Product Declaration, available on our website.
Moisture resistance:
Fire-teK Beam and Column Slab is non-wicking when tested to BS 2972:1989: Section 12. When exposed to 90% humidity and 20°C, Fire-teK Beam and Column Slab absorbs less than 0.004% of moisture.
Handling and storage:
Fire-teK Beam and Column Slab is easy to handle and install, and is easily cut to size, where necessary. Fire-teK Beam and Column Slab is supplied loose on hooded pallets which are designed for short term protection only. For longer term protection on site, the product should either be stored indoors, or under cover and off the ground. Fire-teK Beam and Column Slab should not be left permanently exposed to the elements.
Color | Brown Silver |
Finish | Foil Aluminium foil: Face on one side. |
Material | Rock mineral wool |
Shape | Rectangle |
Size | 1800 x 1200 mm |
Uniclass | |
CAWS | null Mineral wool insulation boards null Mineral wool insulation null Mineral wool insulation boards null Mineral wool insulation boards B11/240 Thermal insulation B13/241 Thermal insulation H11/780 Thermal insulation J21/425 Mineral wool insulation H90/400 Thermal insulation H92/776 Thermal insulation H92/775 Thermal insulation J21/230 Insulation H30/311 Mineral wool thermal insulation H30/310 Mineral wool thermal insulation H31/271 Mineral wool thermal insulation H31/270 Mineral wool thermal insulation H62/230 Mineral wool insulation on structural metal liner trays H64/305 Mineral wool insulation on structural metal liner trays J31/334 Mineral wool insulation H65/230 Mineral wool insulation on structural metal liner trays H67/305 Mineral wool insulation on structural metal liner trays H60/230 Mineral wool insulation on structural metal liner trays H61/230 Mineral wool insulation on structural metal liner trays J41/425 Mineral wool (MW) insulation K40/285 Insulation K45/425 Insulation H30/40 Thermal insulation H31/50 Mineral wool thermal insulation P12/40 Mineral wool rigid batts J31/26 Thermal insulation J41/26 Thermal insulation J42/27 Thermal insulation J42/425 Mineral wool (MW) insulation P12/360 Mineral wool rigid batts K10/85 mineral wool insulation K40/55 Insulation K45/50 Insulation |
General requirements | Insulation products generally. |
Standard | To BS 476. |
Thickness | 20 mm.25 mm.30 mm.35 mm.40 mm.45 mm.50 mm.60 mm.65 mm. |
Facing | Foil faced.Fire-teK Beam and Column Slab is also available with a bright Class '0' aluminium foil facing. |
Edges | Square. |
Thermal conductivity (maximum) | 0.035 W/mK. |
Fire performance | Non-combustible to BS 476-4:1970 (1984), Class 1 Surface Spread of Flame to BS 476-7:1997. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Platform | Compatible | Version | Certified to |
---|---|---|---|
![]() | - | 1 | 2.1 |
![]() | - | 1 | 2.1 |
Fire-teK Beam and Column Slab (Unfaced) Insulation
Knauf Insulation DriTherm® Cavity Slab 32
Knauf Insulation DriTherm® Cavity Slab 34
Knauf Insulation DriTherm® Cavity Slab 37
Knauf Insulation FactoryClad Roll 32
Knauf Insulation FactoryClad Roll 40
Knauf Insulation Loft Roll 40
Knauf Insulation Loft Roll 44
Knauf Insulation Masonry Party Wall Slab
Knauf Insulation OmniFit® Roll 40