BBA Agrément Certificate
Certificate type
QA Certificate
Certificate type
Insulated, metal stud partition system with 30 minutes fire resistance.
Insulated, metal stud partition system based on Fermacell and Powerpanel H20 linings.
Uniclass 2015 | |
CAWS | K10/125 Metal stud partition system K10/30 Metal stud |
Product Reference | Fermacell 1S13 H20 Insulated Partition |
Metal studs | 50 mm75 mm100 mm |
Lining finishes | Powerpanel Surface FinishN.B. Tiles must NOT be fixed over Powerpanel Surface Finish. TilesN.B. Tiles must NOT be fixed over Powerpanel Surface Finish. |
Joint treatment | Fermacell Jointstik 1 mm glued jointFermacell Square edged boards and Powerpanel H2O Boards. Fermacell Joint Filler 5–7 mm filled jointFermacell Site cut boards. Fermacell Joint Reinforcement Tape and Fermacell Joint FillerFermacell Taper edge boards. |
Standard product features | Fire resistance: 30 minutes. Stud centres: 600 mm. Linings: One layer of 12.5 mm and one layer of 10 mm Fermacell Gypsum-Fibreboard to one side and one layer of Fermacell Powerpanel H20 to the other side. Ensure correct jointing method for board type. N.B. For Powerpanel H2O - ALL joints must be fully supported / backed. - Fixings: Fermacell Side - first layer 30 mm Fermacell screws at 400 mm centres and second layer 40 mm Fermacell screws at 250 mm centres. Powerpanel H2O Side - 35 mm Powerpanel screws at 250 mm centres. Fermacell finishing: Fermacell Fine Surface Treatment (FST) to Fermacell Boards only. Powerpanel Surface Finish to Powerpanel H2O Boards. N.B. Tiles must NOT be fixed over Powerpanel Surface Finish. Insulation (minimum density): 40 mm mineral wool: 50 kg/m³. 60 mm mineral wool: 25 kg/m³. Recycled content: Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable. Other requirements: All Powerpanel H2O joints must also be reinforced with an alkali resistant 70 mm Glass Fibre Mesh reinforcement Tape embedded into the Powerpanel surface finish. Fire stopping around service penetrations. Frame out openings with the same number of layers of board as per above specification. Sockets backed using baffle boxes, intumescent putty pads or suitable rock mineral wool, sufficient to maintain the fire/acoustic performance. Movement joints are required at maximum 8 linear metre intervals. Refer to manufacturer's literature. Vapour barrier as required for high humidity areas. For tiled areas reduce studs to 400 mm centres as required Tile adhesive to be suitable for gypsum based or Cement based substrates (dependant on board type). Provide door reinforcement as required to suit door weights and opening size. Ensure no vertical joints at door jambs. Offset all board joints by minimum 200 mm. For Powerpanel H2O - ALL joints must be fully supported / backed. |
Product Options | Metal studs:
Partition performance (based on stud type): - 50 mm stud:
- 75 mm stud:
- 100 mm stud:
|
Recycled content | Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable |
Fermacell 1S11 H20 Insulated Partition
Fermacell 1S11 Insulated Partition
Fermacell 1S12 H20 Insulated Partition
Fermacell 1S15 Partition
Fermacell 1S21 Insulated Partition
Fermacell 1S22 Partition
Fermacell 1S24 Insulated Partition
Fermacell 1S25 Insulated Partition