NBS Source
I'm a manufacturer

Application

Suitable for use within sanitary facilities.

Description

Hydraulic, self-closing pillar mixer tap for use within sanitary facilities.


Features and benefits:

  • Includes self-closing cartridge.
  • Tap is hydraulically controlled, has a piston-free design and stepless adjustment of flow duration.
  • For connection to pre-mixed hot water or cold water via hoses with integrated backflow preventer and strainers.
  • Includes temperature lever with adjustable, turn-proof temperature stop.
  • Casing is manufactured from high-polished, chromium-plated brass.
  • Includes aerator with an integrated flow regulator of 3.0 L/min.
  • Manual operation, tap hole mounted.

General information

Color

Silver

Finish

Polished

Guidance for specification option:

High-polished chromium-plated finish.

Material

Brass

Guidance for specification option:

Chromium-plated brass.

Length

138 mm

Width

45 mm

Height

150 mm

Uniclass

Pr_40_20_87_99 Washbasin thermostatic water supply setsPrimary

CAWS

N13/30 Washbasins

N13/335 Washbasins

Product range

Taps

Specification data - Washbasin thermostatic water supply sets

Form

Manual operation, tap hole mounted.

Materials

-

Body

Brass.

Finish and colour

Chrome plated.

Guidance for specification option:

High-polished.

Accessories/ Other requirements

Not required.

2030012758.

Guidance for specification option:

Thermostatic mixing valve.

2030035383.

Guidance for specification option:

Twist-proof set.

Dimensions

45 x 138 x 150 mm.

Manufacturer guidance

  • Spout projection: 100 mm.
  • Diameter (nominal): DN15.
  • Inlet: G 3/8".

VolumetricFlowRate

0.05 L/s.

Guidance for specification option:

Flow rate achieved at 3 bar pressure.

Manufacturer guidance

Calculation flow rate (cold and hot water): 0.7 L/s.


Water pressure

1 bar.

Guidance for specification option:

Pressure required for minimum flow.

Open time (minimum)

5 s.

Guidance for specification option:

Minimum flow time of 5 seconds.

Operating time

20 s.

Guidance for specification option:

Maximum flow time of 20 seconds.