Application

Suitable for fire and smoke check doors, with connection to RZ 12 emergency exit control or door terminals with control and interface board TL-S5/TL-S8.

Description

Prepared for connection to RZ 12 emergency exit control or to door terminals with control and interface board TL-S5/TL-S8. Provides immediate, jam-free unlocking action and is equipped with anti-tamper and door monitoring contacts. Electro-mechanical door locking element (failsafe principle) with anti-tamper and door monitoring contacts, integrated positive-action monitoring for active/inactive status. Housed in anti-corrosion and anti-tamper metal enclosure, spray painted.


Features and benefits:

  • Maximum holding force in accordance with “Requirements for electrical locking systems on doors in emergency escape routes” (German EltVTR code of practice).
  • Power supply: 24 V DC, +15/–10% with current input approximately 250 mA and contact rating 24 V, 500 mA (door contact).
  • Provides 24 V, 500 mA induktive / 24 V, 1 A ohmic feedback signal “lock/ unlocked”.
  • Anti-tamper line: 3.3 kOhm terminal resistor.
  • Recommended cabling: I-Y (ST) Y4 x 2 x 0.6 mm.
  • Monitoring device optional connection to RZ 12 emergency exit control or door terminals with control and interface board TL-S5/TL-S8.

General information

Color

Silver

Guidance for specification option:

TV-Z 101.

Brown

Guidance for specification option:

TV-Z 103: Dark brown.

White

Guidance for specification option:

TV-Z 111: White, similar to RAL 9016.

Finish

Stainless steel

Guidance for specification option:

TV-Z 104 stainless steel “Design” finish.

Material

Steel

Size

190 x 55 x 80 mm

Guidance for specification option:

(w x h x d).

Uniclass

Pr_30_36_08_84 Special function door locksPrimary

CAWS

P21/26 Special function door locks

P21/530 Special function door locks

Product range

Door Controls / Locks and Levers

Specification data - Special function door locks

Material and finish

Silver.

Monitoring device

Not required.

RZ 12 emergency exit control.

Guidance for specification option:

Optional connection to RZ 12 emergency exit control or door terminals with control and interface board TL-S5/TL-S8.

Accessories

Not required.

Mounting unit TV-Z 101.

Guidance for specification option:

Mounting unit for installation of electromechanical door locking element on flush-closing doors. Galvanized steel angle with spray-painted cover; screw fixings tamper-protected. Dimensions: 190 x 58 x 84.5 mm (w x h x d, approximately).

Shim set TV-Z 01.

Guidance for specification option:

Shim set to compensate for installation tolerances when mounting the electro-mechanical door locking element. 2 shims 1 mm thick, 1 shim 3 mm thick.

Dimensions

190 x 55 x 80 mm.

Guidance for specification option:

w x h x d.

Power supply

24 V d.c.

Guidance for specification option:

  • Power supply: 24 V DC, +15/–10% with current input approximately 250 mA and contact rating 24 V, 500 mA (door contact).
  • Provides 24 V, 500 mA induktive / 24 V, 1 A ohmic feedback signal “lock/ unlocked”.
  • Anti-tamper line: 3.3 kOhm terminal resistor.
  • Recommended cabling: I-Y (ST) Y4 x 2 x 0.6 mm.


Input current

250 mA.