EL582 handle controlled lock case for solid doors with 50 mm backset.

Jump to:
+44 (0)1902 364500 Website

Application

  • Suitable for use as interior and exterior exit or fire rated doors of business premises, public buildings, hospitals and schools.
  • Can be used in the exterior doors of residential buildings.
  • Not suitable for use with door automatics.

Description

Handle controlled lock case for solid wooden or metal doors with a 50 mm backset. The locks are automatically deadlocked when the door is closed and can be controlled by card reader, keypad and timer systems. 


Features and benefits:

  • Deadlocked latch bolt with either a 14 or 20 mm throw.
  • Bolt position and handle operation.
  • Outside handle controlled.
  • Request to exit (RQE).
  • Selection of controlled follower side and side of handle control.
  • Easily reversible trigger bolt and deadbolt, suitable for all hands of door.
  • Quick change fail locked to fail unlocked.
  • Automatic deadlocking of deadbolt only when door shuts.
  • Retrofits mechanical Scandinavian mortice locks.
  • Change of handing.
  • Programmable fail locked/ fail unlocked function.

General information

Finish

Chrome

Material

Steel

Size

225 x 22 mm

Uniclass

Pr_30_36_08_24 Door latchesPrimary

CAWS

P21/26 Special function door locks

P21/530 Special function door locks

Specification data - Door latches

Standard

To EN 14846.

Latch or lock type

Cylinder mortice lock.

Backset

50 mm.

Material and finish

Chrome plated, steel faceplate.

Latch spring strength

Select to prevent un-sprung lever handles drooping.

Execution

Fasteners for hardware.

Product Reference

Electric Lock Standard Scandinavian 50 mm (EL582)

Voltage

12–24 V d.c.

Guidance for specification option:

-10%,+15%.

Power consumption

550–270 mA.

Guidance for specification option:

Max consumption at 12—24 VDC

(Idle consumption 240—110 mA at 12—24 VDC).

TemperatureRange

-20°C to +75°C.

Forend

22 mm.

Bolt

14 mm.

20 mm.

Manufacturer guidance

Bolt throw.

Configuration

Non-handed.

Spindle

8 mm.