NBS Source
I'm a manufacturer

Electric Lock Standard (EL561)

Verified by manufacturer 10 months ago

Abloy UK

High security DIN standard handle controlled lock.

Jump to:
+44 (0)1902 364500 Website

Application

  • Suitable for use in the interior wooden and metal doors of business premises, public buildings, hospitals and educational premises.
  • Can be used as fire doors in medium traffic environments.

Description

High security lock combining handle controlled unlocking with mechanical security requirements.


When door closes, the straight spindle function engages both handles via electric access control, the dead bolt is thrown out automatically, the double action latch is blocked and the lock case is secured in two points. The inside handle opens the lock mechanically as an exit function.


Features and benefits:

  • Mechanical automatic locking system.
  • Non-handed, left/ right.
  • Can be changed between fail-unlocked and fail-locked.
  • Burglary-resistant dead bolt with 20 mm throw.
  • Mechanical override with cylinder.

General information

Material

Steel

Size

235 x 20 mm

235 x 24 mm

Uniclass

Pr_30_36_08_24 Door latchesPrimary

CAWS

P21/24 Door locks

P21/515 Door locks

Specification data - Door latches

Standard

To BS EN 12209.

Classification grades (minimum)

-

Category of use

BS EN 12209, grade 3.

Durability

BS EN 12209, grade S.

Door mass and closing force

BS EN 12209, grade 8.

Suitability for use on fire resisting and/or smoke control doorset

BS EN 12209, grade 1.

Corrosion resistance and temperature

BS EN 12209, grade F.

Security and drill resistance

BS EN 12209, grade 6.

Key identification requirement

BS EN 12209, grade 0.

Latch or lock type

Cylinder mortice lock.

Backset

55 mm.

60 mm.

65 mm.

80 mm.

100 mm.

Material and finish

Stainless steel faceplate.

Latch spring strength

Select to prevent un-sprung lever handles drooping.

Execution

Fasteners for hardware.

Product Reference

Electric Lock Standard (EL561)

Voltage

12–24 V d.c.

Guidance for specification option:

-10%,+15%.

Power consumption

550–270 mA.

Guidance for specification option:

Max consumption at 12—24 VDC

(Idle consumption 240—110 mA at 12—24 VDC).

TemperatureRange

-20°C to +60°C.

Forend

20 mm.

24 mm.

Spindle

9 mm.

Guidance for specification option:

8 mm with spindle adapters.

Bolt

20 mm.

Guidance for specification option:

Dead bolt.

10 mm.

Guidance for specification option:

Double action bolt.

Manufacturer guidance

Bolt throw.

Configuration

Non-handed.