Verified by manufacturer 5 days ago
BRE Certificate
Certificate type
Flat glass continuous rooflights consisting of multiple linking glass panels
Flat glass continuous rooflight suitable for commercial, public and domestic buildings.
EcoGard multi-pane rooflights provide continuous skylights up to 2500mm wide by indefinite length. Various glass types are available including solar control and low maintenance options. The perimeter frame is thermally broken aluminium and glass fins are available in lieu of the standard aluminium intermediate glazing bar if required.
Color | Silver Clear Guidance for specification option: Infill. Other Guidance for specification option: Polyester powder coated frame to any RAL or BS colour. |
Finish | Glazed Mill Powder-coated |
Material | Aluminium Glass |
Shape | Rectangle Triangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | H10/115 Patent glazing L10/45 Rooflights L10/460 Rooflights |
SKU Code | ECO-FGR |
Form | Flat. Guidance for specification option: Continuous rooflights for Northlights and Longlights. |
Size | Guidance for specification option: Consult manufacturer and insert requirements. Self-supporting spans up to 4.0 m, depending of glazing bar centres, live loads and glazing configuration. |
Product performance | |
Fire performance | |
Fire resistance | External fire exposure: Class AA. Guidance for specification option: To BS 476. |
Reaction to fire | Surface spread of flame: Class 1. |
Frame | |
Material | Extruded aluminium alloy, 6063-T6. |
Finish | |
Coating | Mill finish. Guidance for specification option: Standard. Polyester powder-coated. |
Colour | RAL. Guidance for specification option: Polyester powder coated: Insert RAL or BS colour code. |
Glazing or infill | |
Type | Toughened glass. Laminated glass. |
Construction | Double skin. Triple skin. |
Colour | Clear. Guidance for specification option: Clear neutral solar control tinted solar control. |
Coating | Low E Solar control. |
Operation | |
Type | Manual. |
Design | Guidance for specification option: Insert drawing/ reference. |
Box bar | Box bar 2. Box bar 3. Box bar 4. Manufacturer guidanceConsult manufacturer for further details. |
Combustibility | Non-combustible. |
Non-fragility rating | Required. Guidance for specification option: TN 92 class 1 & 2. Not required. |
Flashings | PPC aluminium. Lead. |
PitchAngle | 5° (minimum). |
Air permeability | 0.71 m³/h.m² at 600 Pa, Class 4. Guidance for specification option: To BS EN 12207: 2016. |
Weather performance | Weather-tight to Class E1650. Guidance for specification option: To BS EN 12208. |
Capping | Extruded aluminium alloy, 6063-T6. |
Fittings | Extruded aluminium alloy, 6063-T6. |
Fasteners | Stainless steel, grade A2. |
Pressure plate | PVC. Manufacturer guidanceCo-extruded. |
Thermal break | PVC. Manufacturer guidanceCo-extruded thermal barrier. |
Gaskets | PVC. |
Opening vents | Not required. Opening vents available. Guidance for specification option: For natural or smoke ventilation. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Material | Aluminium Glass |
Recyclability | Approximately 85% of the product is aluminium which 100% recyclable, remaining 15% is gaskets and thermal liners. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 35 % |