Durasteel Fire Barrier - No insulation
Certifire Certificate
Certificate type
Fire barrier for use in partitioning, ducting, door and ceiling applications.
DURASTEEL® systems have been used successfully for many years, including rail and metro projects, military developments and in commercial, pharmaceutical and petrochemical facilities.
DURASTEEL® has been developed and supported through rigorous testing for use in partitioning, ducting, door and ceiling applications, with a wide range of specifications available.
Features and benefits:
Construction:
Finish | Galvanized |
Material | Steel Guidance for specification option: (Anchors). Stainless steel Cementitious |
Shape | Rectangle |
Uniclass | |
CAWS | K10/125 Metal stud partition system K10/30 Metal stud |
Framing | Guidance for specification option: Perimeter channels fastened to surrounding construction with M10 or M12 all-steel expanding anchors, vertical channels at maximum 1200 mm centres. Horizontal and vertical channel members either welded together or joined with steel angle cleats. |
Insulation | No insulation.Guidance for specification option: Integrity only. |
Cavity fire barriers | Guidance for specification option: Dependent on insulation specified. Fire barriers have 240 minutes' integrity. All fire barriers are resistant to fire attack from either face. |
Fasteners | Guidance for specification option: Manufacturer's standard. |
OverallWidth | 89.5 mm. Manufacturer guidanceDependent on insulation specified. |
Sound reduction | 33 dB. Guidance for specification option: (Estimated). |
Dimensions | 80 x 60 x 3 mm. Guidance for specification option: Vertical and horizontal channels up to 6 m. |