Acoustic glazed internal partitioning system with slim aluminium profile.
Internal glazed partition.
Acoustic glazed partition with slim profiles.
Features and benefits:
If a fire-rated system is required, see the TSG50FS system. A basic system, TSG50, is also available. Both specified separately.
Color | Clear Guidance for specification option: Glazing. Silver Guidance for specification option: Aluminium - polished, linished or anodized. Other Guidance for specification option: Aluminium, powder-coated. |
Finish | Powder-coated Powder-coated Guidance for specification option: Polyester powder-coating. Anodized Guidance for specification option: Etch & anodized. Stainless steel Guidance for specification option: Simulated. Wood grain Guidance for specification option: Simulated. |
Material | Aluminium Glass |
Shape | Rectangle |
Length | Bespoke |
Width | 50 mm Guidance for specification option: Screen profile depth (base/ head/ wall). |
Height | Bespoke Guidance for specification option: Maximum 5000 mm. |
Warranty description | Lifetime Guidance for specification option: Please see TSG50AS data sheet for details. |
Uniclass | |
CAWS | K30/10 Relocatable partition system K30/130 Relocatable partition system |
Unit size | |
Thickness | 50 mm.Guidance for specification option: Profile depth (screen). |
Partition height (nominal) | Guidance for specification option: Insert requirements, maximum 5000 mm. Maximum applies to screens; insert details for door(s) separately below, including side screens and/or overpanels is required. |
Width (nominal) | Guidance for specification option: Insert requirements, including drawing or schedule reference as required. |
Deflection allowance (maximum) | |
Head | No deflection (40 x 50 mm top track head).±25 mm deflection (50 x 50 mm top track head). |
Floor | 40 x 50 mm. |
Verticals | 40 x 50 mm. |
Panel partition type | Glazed. |
Framing, fixing points and joints | 40 x 50 mm aluminium insulated channels with Dribond® DriJoint®/ multi-function posts. |
Solid panels | |
Type | Not required.Alitek companel. |
Finish and colour | Guidance for specification option: Omit if not applicable. Otherwise insert 'As frame', or consult manufacturer for options and insert colour requirements. |
Joint treatment | |
Type | Dribond® DriJoint®. |
Finish and colour | Guidance for specification option: 'As frame', or consult manufacturer for options and insert colour requirements. |
Glazed panels | |
Type | Guidance for specification option: SINGLEglaze® channel; consult manufacturer's literature for options and insert glazing requirements. Manufacturer guidanceUpgradeable glass options available; consult manufacturer for details. Note: this may affect performance details. |
Integral blinds | Not applicable. |
Additional features | Not required.90° multi-function post. |
Door arrangement | |
Type | Dribond® Alitek DR46 doorset, single door leaf.Dribond® Alitek DR46 doorset, double door leaf.Dribond® Alitek DR46 doorset, double door leaf and side screens.Dribond® Alitek DR46 doorset, double door leaf and overpanel.Dribond® Alitek DR46 doorset, double door leafs, side screens and overpanel.Solid core timber door, single leaf.Guidance for specification option: Up to 46 mm thickness; consult manufacturer for options and insert requirements. Include details for glazed side screens and/or overpanels if required. Solid core timber door, double leaf.Guidance for specification option: Up to 46 mm thickness; consult manufacturer for options and insert requirements. Include details for glazed side screens and/or overpanels if required. Manufacturer guidanceConsult manufacturer for details and insert dimensions or refer to drawing/ schedule. |
Locking | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Door frames | Aluminium.Guidance for specification option: Extruded to BS EN 755-9:2001, specification 6063 T6. Consult manufacturer for dimensions. |
Door panels | |
Type | To match glazed panels.Other.Guidance for specification option: Insert glazing requirements (11–26 mm Schott PYRANOVA® multi-layer laminated fire glass). Manufacturer guidanceAlso comprises SiNGLEglaze channels, aluminium extruded to BS EN 755-9:2001, specification 6063 T6. Uses 75% recycled aluminium. Aluminium colour/ finish to match other components unless specified otherwise. |
Vision panels | Not applicable. |
Additional apertures | Guidance for specification option: Insert requirements or omit. |
Ceiling | |
Joint treatment | Dribond® DriJoint®. |
Perimeters, skirtings, sills | None. |
Trims | Not applicable. |
Hardware | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Seals | Dribond® Alitek ADF Acoustic door: Fitted with two acoustic seals around the perimeter as standard. |
Cable management and outlets | Guidance for specification option: Internal cable management is supported. Insert requirements or omit. |
Other features | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Finish (aluminium components) | Polyester powder-coated, colour. Guidance for specification option: Consult manufacturer for options and insert colour requirements. Polished and chemically brightened. Linished and chemically brightened. Etched and anodized. Guidance for specification option: Consult manufacturer for options and insert requirements. Manufacturer guidanceApplies to all components unless specified otherwise. |
Sound insulation | Partition screen: Up to 47 dB (Rw). Guidance for specification option: Standard. Consult manufacturer for details if upgradeable glass options are required. |
Load | 0.74 kN/m. 1.5 kN/m. 3.0 kN/m. Manufacturer guidanceNominal line load criteria of "accidental impact load" utilized. 0.36 kN/m applied as short term load at 1100 mm above FFL. Consult manufacturer's technical team for details. |
Manifestation | Allowance of two rows of 50 mm dots. Allowance of two rows of 50 mm squares. Opal frost. Artwork/ custom. Guidance for specification option: Insert details. Manufacturer guidanceTo specifier's choice and in accordance with the requirements of approved document K. Select multiple options e.g. for door as required. |
Accessories/ Special requirements | Not applicable. Sustainability: system to conform to the requirements of BREEAM. Sustainability: system to conform to the requirements of SKA. Sustainability: system to conform to the requirements of LEED. Other. Guidance for specification option: Consult manufacturer for options e.g. BIM and insert details. Manufacturer guidanceInsert details as required. |
Strength grade | Manufacturer's standard. Guidance for specification option:
|
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 4 kg CO₂ eq/unit Self declared |
Recyclability | System is fully recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 72 % |
Dribond SINGLEglaze TSG50FS Fire Rated System - Fire-rated Glazed Partition System
Dribond SINGLEglazed SG30FS Concept Fire Rated System - Fire-rated Glazed Partition System
Dribond SINGLEglaze® SG30 Concept System - Acoustic Glazed Partition System
Dribond SINGLEglaze® SG30AS Concept System - Acoustic Glazed Partition System
Dribond SINGLEglaze® TSG50 System - Glazed Partition System
Dribond TG100FS System Ei Fire Rated Integrity-Insulation - Fire Rated Glazed Partition System
Dribond TWINglazed TG100AS Acoustic System - Seamless Double Glazed Acoustic System
Dribond TWINglaze® TG100 System - Seamless Double Glazed System
Dribond TWINglaze® TG90 System - Seamless Double Glazed System
Dribond TWINglaze® TG90AS System - Seamless Double Glazed Acoustic System