Door frame and architrave protection.

Jump to:
+44 (0)113 279 5854 Website

Application

Suitable for new and existing door frames and architraves

Description

Extruded or post-formed protective PVCu coverings for new and existing door frames. Designed to prevent damage and reduce maintenance costs.


Approvals:

Extruded Textured Material fire tested to:

  • B, s2, d0.
  • BS EN 13823:2010 + A1:2014.
  • BS EN ISO 11925 - 2: 2010.
  • BS EN 13501 - 1: 2007 + A1:2009.
  • BS 476: Part 7: 1997 - The surface spread of flame of products- Class 1Y.
  • BS 476: Part 6: 1989 + A1:2009- Fire propagation for products - Class O - As defined in the latest Building Regulations, Approved Document B (Fire Safety).


Smooth Extruded Frame Protection Products:

  • CFR1101041 Rev 1 & CFR1002181 Rev2.
  • BS EN 1634-1 :2008 (1Hr).
  • BS EN 1634-1 :2008 (1/2 Hr).


VOC Emissions

Yeoman Shield PVCu Falmouth Wall & Door Protection panels have been tested for VOC to ISO 16000-10:2006 Indoor air - Part 10.

 

The test showed the following results:

 

<10 µg m‑2 h‑1 for TVOC

<5 µg m‑2 h‑1 for Formaldehyde

 

The interpretation of these results by BRE are if all the walls (less door and window) of the 30 m3 reference room described in BS EN 16515‑2017

(with a ventilation rate of 0.5 air changes per hour) were clad with our Yeoman Shield PVCu Falmouth Wall & Door Protection Panels, the increase in TVOC in the room would

be <20 µg m‑3 for TVOC and <10 µg m‑3 for Formaldehyde and these are deemed to be low.

 

BREEAM Hea02 has limits of 300 µg m‑3 for TVOC and 100 µg m‑3 for Formaldehyde, so the theoretical increases in TVOC and Formaldehyde from

using our PVCu sheet are deemed as low

General information

Color

White

Grey

Guidance for specification option:

  • Graphite RAL 7046 (nearest)- stock colour


Manufacturer guidance

Consult manufacturer for colour range.

Finish

Smooth

Material

PVC-U

Length

Bespoke

2300 mm

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_23_96 Wood door framesPrimary

CAWS

P20/170 Proprietary

P20/30 Proprietary

Specification data - Wood door frames

Third party accreditation

To BS EN 13823:2010 + A1:2014; BS EN ISO 11925 - 2: 2010; BS EN 13501 - 1: 2007 + A1:2009 and B, s2, d0 .

Fire performance

To BS 476: Part 7: 1997 - Class 1Y; BS 476: Part 6: 1989 + A1:2009- Class O and Building Regulations, Approved Document B.

Dimensions

-

Standard

2300 mm.

Guidance for specification option:

Extruded.

2500 mm.

Guidance for specification option:

Post formed, lengths up to.

2400 mm.

Guidance for specification option:

Universal frame protector, lengths up to.

Manufacturer guidance

Length.

Finish

-

Manufacturer guidance

Consult manufacturer for details.

Colour

-

Manufacturer guidance

Consult manufacturer for colour range.

Type

Architrave, radius/ radius.

Guidance for specification option:

15 x 50 x 15 mm.

Architrave, square/ radius.

Guidance for specification option:

18 x 50 x 18 mm.

Architrave, square/ splayed.

Guidance for specification option:

18 x 25 x 20 x 15 mm.

Stop lath.

FD30 softwood.

Guidance for specification option:

18 x 45 x 18 mm.

Show more

Construction

Extruded.

Guidance for specification option:

  • Manufactured from extruded Vinylac, to set dimensions in smooth finish available in white or graphite only.
  • Available with or without core inserts, for architraves, stop laths & frame sections.
  • Suitable for repair work or new build.
  • Available in 2.3 m lengths


Post-formed.

Guidance for specification option:

  • Manufactured from post-formed Vinylac. In FalmouthEx or HessianEx finish to suit most standard profiles.
  • Suitable for protecting both existing and new frames and architraves.
  • Available in lengths up to 2.5 m long.


Universal frame protector.

Guidance for specification option:

Manufactured with a 65 x 65 mm leg (small sizes available on request) and a 20 mm formed corner, supplied in lengths up to 2.4 m.

Inserts

MDF.

Hardwood.

Softwood.

None.

Texture

FalmouthEx.

Guidance for specification option:

  • Light relief pattern.
  • Post-formed protectors only.

HessianEx.

Guidance for specification option:

  • Decorative pattern.
  • Post-formed protectors only.

Smooth.

Guidance for specification option:

Extruded protectors only.

Third party certifications

Health & Safety Accreditation

Health & Safety Accreditation

Alcumus Safecontractor

CHAS

CHAS

CHAS accreditation advanced

Constructionline

Constructionline

Constructionline

Warringtonfire

Warringtonfire

Firas certification scheme

ISO 9001 Quality Management

ISO 9001 Quality Management

NQA ISO 9001

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

NQA ISO14001

Literature

Yeoman Shield Wall & Door Protection Product Brochure

Yeoman Shield Wall & Door Protection Product Brochure

Case studies

Colourful, Practical Door Protection for Radiology Department.

Colourful, Practical Door Protection for Radiology Department.