Verified by manufacturer 5 days ago
5 Series DS R-FI - PHEX Size 1
ISO 9001 Quality Management
Certificate type
Range of heat interface units supplying instantaneous domestic hot water and direct heating.
Suitable for domestic applications.
Range of heat interface units supplying instantaneous domestic hot water and direct heating.
Features and benefits:
Color | White Grey |
Finish | Lacquered |
Material | Steel Polypropylene |
Shape | Rectangle |
Length | 235 mm 240 mm 270 mm |
Width | 528 mm 540 mm 530 mm |
Height | 690 mm 800 mm 710 mm |
Uniclass | |
CAWS | S90/230 Instantaneous hot water supply S90/130 Instantaneous hot water supply T90/110 Heating system |
Duty | |
Primary flow temperature | 60℃.70℃. |
Primary return temperature | 17.3–20.5℃. |
Pressure drop | 45 kPa. |
Flow rate | 14.0–18.4 L/min. |
Heating supply temperature | 99°C. |
Hot water supply temperature | 45–50℃. |
Casing | Not required.White lacquered steel cover.Guidance for specification option: Optional. |
Insulation | Full EPP insulation.Manufacturer guidanceThermal conductivity: 0.038–0.040 W/(m2 *K). |
Components | |
Primary | Domestic hot water heat exchanger. |
Secondary | Isolating valve. |
Controls | DHW - IHPT self-acting mechanical controller. |
Capacity | 39.0–51.0 kW. |
Dimensions | 690 x 528 x 235 mm. Manufacturer guidanceH x W x D. |
Pressure | Nominal pressure: PN 10. |
Country of product manufacture | Denmark |
Manufacturing plant location | |
Material | Steel Polypropylene |
RavenResidential Ironworks, Mill Road Case Study
Quayside Extra Care, Totnes - FlatStation Case Story
Pressure Independent Thermostatic Radiator Valves Case Study
Middlewood Locks - FlatStation Case Story
District Heat-as-a-Service
Case Story Greenside Views, Mitcham, London
Agar Grove Camden - Heat Interface Unit Case Story
Case Story - Harvesters Way, Edinburgh