CGL Traypanel Rainscreen - Aluminium Panel
Fire Safety Certification
Certificate type
CWCT Certificate
Certificate type
ISO 14001 Environmental Management Systems
Certificate type
ISO 9001 Quality Management
Certificate type
CCPI Product
Certificate type
Metal panel rainscreen cladding system.
Suitable for use on a building envelopes exterior facade in high-rise, hospitals, student accommodation and hotel applications.
CGL is a rainscreen cladding system with horizontal or vertical Traypanel cassette type panels discreetly fixed into an extruded aluminium support structure, supported by helping hand brackets attached back to the primary structure. The rainscreen wall design shall include all components such as membranes and insulation that together will ensure compliance with current building regulations.
The system is a drained rear-ventilated rainscreen façade. Air pressure in the cavity behind the panels generally equalises with pressure outside to prevent wind-driven rain from entering the cavity. Any moisture which does enter the cavity, drains down the back of the panels and exits in a controlled fashion at horizontal or vertical joints and the base of the facade.
In order for the rainscreen principle to function, the backing wall from which it is supported must achieve certain standards of air permeability, stipulated in The Building Regulations, and be capable of accommodating transmitted live and dead loads. The backing wall must also achieve specified performance requirements for fire, acoustics, and condensation risk.
The system have been formally tested with certification from a UKAS accredited testing facility, which complies with testing requirements laid out in the CWCT publication, 'Standard for systemised building envelopes - 2005'.
Features and benefits:
With the exception of Cor-Ten Steel, a removable protective film is supplied on all panels and remains in place through the installation processes to inhibit damage. CGL recommend the film be removed on the day of panel installation otherwise there is the risk that adhesive residue/staining will remain on the panels after later removal.
Color | Beige Black Blue Bronze Brown |
Finish | Natural Polished Textured Anodized Powder-coated |
Material | Aluminium Guidance for specification option: Aluminium Pre-coat. Aluminium Post -coated. Copper Zinc Stainless steel Carbon steel Guidance for specification option: Corten Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 20 year Guidance for specification option: 20 year standard warranty, subject to local environment. Refer to manufacturer for project specific warranties. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Thermal insulation | Manufacturer guidanceAn essential part of the backing wall is the wall insulant. Insulation should never be applied to the Traypanels themselves, but always to or into the backing wall. The insulation should be resistant to moisture and provide adequate fire performance, based on the building construction and end use. Calculations are required to ensure that the overall construction achieves the specified U-value and include the effect of any regular cold-bridging of wall components. |
Breather membrane | |
Material | Manufacturer guidanceThe manufacturer recommends as good practice to apply breather membrane to the cold side of the wall insulant. If properly fitted and joint-sealed, this membrane will stop moisture penetrating the backing wall. Where wall brackets penetrate the insulation layer, particular care should be taken to seal the membrane around these penetrations. Vapour barrier membranes may also require to be fitted on the warm side of the insulant and a condensation risk analysis identifies if a membrane is needed. |
Secondary support structure | Aluminium support structure – A fully adjustable system of support brackets and rail profiles. Material: Extruded aluminium to BS EN 12020-2 in 6063 T6 grade alloy.Manufacturer guidance
|
Cavity fire barriers | |
Horizontal | Supplied by others.Manufacturer guidanceThe manufacturer recommends in order to inhibit the spread of fire and smoke through the ventilated cavity, it is required to break the cavity with non-flammable closures. These can be made from rock-fibre bats or perforated intumescent sheeting and are usually fitted at floor slab levels, building corners, and around window penetrations. |
Vertical | Supplied by others.Manufacturer guidanceThe manufacturer recommends in order to inhibit the spread of fire and smoke through the ventilated cavity, it is required to break the cavity with non-flammable closures. These can be made from rock-fibre bats or perforated intumescent sheeting and are usually fitted at floor slab levels, building corners, and around window penetrations. |
Cladding panels | |
Material | Aluminium Panel. |
Panel joints | Labyrinth joints (discreet fix). |
System accessories | Bullnose unit.CopingDrainage channel.FlashingInsulated gutters, PIR.Insulated gutters, Rockwool.Rainwater goods. |
Type: | Horizontal Traypanel. Vertical Traypanel. |
Colour/ Finish: | Anodized. Polyester powder coating (PPC). Pre-coat (PVDF). Manufacturer guidanceAll colours available, consult manufacturer for details and insert requirement. |
Water penetration | Peak test pressure: 600 Pa. |
Wind resistance | Peak test pressure: 2400 Pa (Serviceability), 3600 Pa (Safety). |
Impact resistance | Category B (Retention and Safety to persons). |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Aluminium Guidance for specification option: Aluminium Pre-coat. Aluminium Post -coated. Copper Zinc Stainless steel Carbon steel Guidance for specification option: Corten Steel |
Recyclability | 95% Recyclability. Guidance for specification. All aluminium components are fully recyclable and can be taken to suitable recycling centres. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |