Verified by manufacturer 1 month ago
A1 Natural Textures Raw
EPD
Certificate type
CCPI Product
Certificate type
Complete system specification for Ceramapanel and VitraFix including VF3 secret-fix brackets, plus fixings to the wall from Certifix.
Particularly suited to both internal and external modern commercial, residential and industrial buildings, where a natural facade is needed.
Undercut fixings are used to attach the VitraFix VF3 brackets to the rear of the panel, the brackets are spaced at a maximum of 10x panel thickness to the edges of the panel and up to 450 mm from each other.
It is important to check with the undercut fixing manufacturer as to depth of insertion to ensure fixings are correctly and securely installed. The VF3 brackets ‘hook’ onto the VF3 horizontal rails which are in turn installed to the Vitrafix VF1 or VF2 carrier sub frame. The top row of VF3 brackets are used to level and ‘dead fix’ the panels to the sub frame.
A complete system specification for Ceramapanel and VitraFix, plus fixings to the wall from Certifix (in partnership with Valcan). This provides a comprehensive warranty on the complete system. All Certifix provided products are tested and certified in accordance with ADB v2 for high rise buildings.
All batch numbers will be recorded, regular site visits to be made by Valcan and Certifix during the installation, frequency to be decided at order stage with client.
Ceramapanel:
A through coloured, compressed fibre cement facade panel available in 8, 10 or 12 mm thicknesses, in A1 rating as required. It is both an aesthetically appealing and cost-effective cladding solution offering a natural appearance. It also has good acoustic dampening properties.
Features and benefits:
Ceramapanel technical characteristics:
Durability:
The cement panel is highly durable and includes immunity to permanent water damage in both short and long-term exposure. It will not rot, burn or corrode and is unaffected by termites, air, steam, salt and sunlight. It is not adversely affected over a temperature range of -20 to +60°C.
Vitrafix systems:
Aluminium carrier system brackets, profiles and fixings which are Centre for Window and Cladding Technology (CWCT) tested. Designed to offer a cost effective yet strong carrier system, and is suitable for all building types.
Features and benefits:
Color | Beige Black Blue Brown Green |
Finish | Smooth Textured Painted |
Material | Fibre cement |
Warranty description | 15 year Guidance for specification option: Ceramapanel; consult manufacture for further details. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performance | Manufacturer guidanceInsert requirements. |
Thermal insulation | Certifix mineral wool rainscreen slab, thickness.Guidance for specification option: Insert required thickness. Thermal performance: 0.034 W/m·K. Fire rating (to BS EN 13501-1): A1. Fixings: CIA/FR Certifix fire-rated insulation fixings. |
Breather membrane | |
Material | CFA1BM CertiShield Class A2 Breather Membrane.Guidance for specification option: Fire performance (to BS EN 13501-1): A1. |
Fasteners | Manufacturer's standard. |
Secondary support structure | Vitrafix VF3/ VF1.Guidance for specification option: See below for options for: Brackets; rails; horizontal rails; fixings; accessories. Vitrafix VF3/ VF2/ VF1. |
Cavity fire barriers | |
Horizontal | Certifix VRFB+ open state horizontal barrier.Manufacturer guidanceFixings: Fire-tested fixings to be advised by Certifix Ltd to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Vertical | Certifix NVRFB non-ventilated vertical barrier.Manufacturer guidanceFixings: Fire-tested fixings to be advised by Certifix Ltd to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Cladding panels | |
Material | Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 8 mm.Guidance for specification option: Weight: 14.4 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 8 mm.Guidance for specification option: Weight: 18.0 kg/m². Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 10 mm.Guidance for specification option: Weight: 18.0 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 10 mm.Guidance for specification option: Weight: 18.0 kg/m². Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 12 mm.Guidance for specification option: Weight: 21.6 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 12 mm.Guidance for specification option: Weight: 21.6 kg/m². Manufacturer guidanceSee product description for technical characteristics. Fixing: VFR4.820C Vitrafix 4.8x20mm Rivet A4/A4 (5–13 mm). Fixings should be spaced 45–65 mm from edge measured with the fibres and 25–50 mm from edge measured across the fibres. |
Panel joints | 8–10 mm open joints. |
Reveals | Not required.25 mm-wide window flashing profile. |
Colour/ Finish | 1111 Vanilla. 1031 Charcoal. 1121 Sky Blue. 1061 Eucalyptus. 1011 Rain Cloud. Manufacturer guidanceThe Raw finish features a smooth sanded face that is suitable for clean, modern facades. The natural nuances of fibre cement are more apparent in this finish Natural range resembles nature’s earth tones and has a much more natural look. |
Fire rating (to BS EN 13501) | Manufacturer's standard. |
Brackets | VF100DB 100 mm double bracket (no pad). Guidance for specification option: 102–132 mm adjustment. VF100SB 100 mm single bracket (no pad). Guidance for specification option: 102–132 mm adjustment. VF140DB 140 mm double bracket (no pad). Guidance for specification option: 142–172 mm adjustment. VF140SB 140 mm single bracket (no pad). Guidance for specification option: 142–172 mm adjustment. VF180DB 180 mm double bracket (no pad). Guidance for specification option: 182–212 mm adjustment. |
Rails | VF3 secret fix rail/ VFTR503 T-rail, 50 x 100 x 3000 mm. VF3 secret fix rail/ VFTR506 T-rail, 50 x 100 x 6000 mm. VF3 secret fix rail/ VFLR503 L-rail, 50 x 100 x 3000 mm. VF3 secret fix rail/ VFLR506 L-rail, 50 x 100 x 6000 mm. Manufacturer guidanceVF3 secret fix rail: Aluminium, 6000 mm long. |
Horizontal Rails | Vitrafix VF2/U 90 x 15 x 2 mm. Guidance for specification option: Length: 3000 mm. Vitrafix VF2/U 174 x 15 x 2 mm. Guidance for specification option: Length: 3000 mm. Not required. Guidance for specification option: Not required for masonry walls. Manufacturer guidanceVF2/U attached to SFS locations allowing brackets to be installed in isolation to stud location. Fixing to stud: VFSD.538/A4 – Vitrafix self-drill, A4 grade 5.5 x 38 mm, 8 mm hex head w/washer – consult manufacturer's details for fixing centres. |
Secret Fix Brackets | Vitrafix VF3 Secret Fix bracket – fixed. Guidance for specification option: Consult manufacturer for fixing/ bracket part number. |
Fixings | VFSD4.825/A4 Vitrafix self-drill, 4.8 x 25 mm, A4 grade, 8 mm hex head. VFSD.538/A4 Vitrafix self-drill, 5.5 x 38 mm, A4 grade, 8 mm hex head w/washer. Masonry anchors by Certifix Ltd - ETA approved, fire-rated fixing. Guidance for specification option: Certifix Ltd to carry out pull-out test on site to determine correct fixing. |
Accessories | None. VFIPDB Double bracket thermal pad. Guidance for specification option: Adds 3 mm adjustment. VFIPSB Single bracket thermal pad. Guidance for specification option: Adds 3 mm adjustment. |
Sheathing board | ProcellaPro. Guidance for specification option:
|
Cavity | Depth: 50 mm open joint installation. Guidance for specification option: Measured from face of insulation to rear of panel; can be reduced by 50% at fire barrier locations or other “pinch” points. Other. Guidance for specification option: Consult CWCT section 3.4.4.4 and insert requirements. |
Material | Fibre cement |
Recyclability | Recyclable |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Ceramapanel & VitraFix Rivet Fix Non-Combustible A1 Cladding System
Ceramapanel – Fibre Cement Non-Combustible A1 Cladding Panels
Evverlap A2 Fibre Cement VF1 Cladding System
Evverlap A2 Fibre Cement VF2 Cladding System
VitraDual - Non Combustible A1 Cassette Fix Cladding System
VitraDual - Non-Combustible A1 Aluminium Cladding Panel
VitraDual A1 Non-combustible Planking System Fix
VitraDual A1 Non-combustible Rivet Fix Cladding System