Application

H+H UK Ltd can offer a fast-build masonry alternative to both Timber Frame and aggregate. Designated as an MMC under the Mark Farmer Review, Vertical Wall Panels are erected onsite and can build a house shell from DPC to Roof in just five days.


Celcon Vertical Wall Panels are intended for the construction of domestic houses of up to two storey with room in the roof. Three storeys may also be considered subject to an engineering appraisal.

Description

Celcon Vertical Wall Panels are storey-high aircrete panels - fabricated offsite and craned into place for a fast, panelised building system with the reassuring characteristics of a high-performance, durable, masonry structure.


Celcon Vertical Wall Panels are manufactured in a range of heights with a width of 600 mm and a thickness of 100 mm.


Vertical Wall Panels are craned into place onto a bed of H+H element mortar – a fast-setting and very strong thin-layer mortar developed especially for use with the panels. 


Features and benefits:

  • MMC category 2, 3 & 6 compliant
  • Fast build on site from DPC to roof in 5 days
  • Achieves latest Part E and Part L regulations
  • Recognised under NHBC and NHBC Accepts
  • Twice awarded Housebuilder Product Awards
  • BOPAS accredited (when used in I-House)
  • Class A1 fire rating, non-combustible
  • Reduces site labour requirements

General information

Color

Grey

Finish

Matt

Material

Autoclaved aerated concrete (AAC)

Shape

Rectangle

Length

100 mm

Width

600 mm

Height

2325 mm

Uniclass

Pr_20_93_52_05 Autoclaved aerated concrete (AAC) blocksPrimary

CAWS

F10/36 Concrete common blockwork

F10/355 Concrete common blockwork

F10/37 Autoclaved aerated concrete (AAC) common blockwork

F10/360 Autoclaved aerated concrete (AAC) common blockwork

Specification data - Autoclaved aerated concrete (AAC) blocks

Mean compressive strength (minimum)

4.0 N/mm².

Thermal conductivity (maximum)

0.17 W/mk (at 3% moisture).

Work sizes (length x width x height)

100 x 600 x 2325 mm.

Tolerance category

To BS EN 12602, T3.

Density

575 kg/m³.

Shear bond strength

0.3 N/mm².

Water absorption by capillarity

Not for unprotected use.

Water vapour permeability

05/10.

Weight

116 kg.

Vapour resistivity

50 MNs/gm.

Water vapour diffusion resistance

10.

Mortar

Dunnbettmortel - M10 thin layer mortar supplied in 15 kg bags.

Thickness

100 mm.

Specific heat

1.05 kJ/kgK.

Shrinkage

<0.2mm/m.

Coefficient of linear expansion

8 x 10-6/K.

Air tightness

0.1 m³/hour/m².

AcousticRating

Rw at 100 mm: 40.0 dB unfinished, 42.6 dB lightweight plaster, 45.8 dB, dense plaster.

Fixings

Plugged and screwed fixings.

Guidance for specification option:

Wood screw, Rawlplug, Unifix, Fischer.

Nailed fixings.

Guidance for specification option:

Helifix, Loden.

Hammer/ screw fixings.

Guidance for specification option:

Rawlplug.

Manufacturer guidance

  1. The diameter of holes drilled in the blocks should be such that the plug fits tightly prior to the screw being driven. Woodscrews driven direct should not be over tightened. Cut nails driven direct should not be over hammered.
  2. The size and length of a fixing should be suitable for the block thickness.
  3. Generally, fixings should be spaced from each other (and from the free edge of a block when this is applicable) at a distance not less than the depth of penetration of the fixings into the block; this should be confirmed with the fixing manufacturer.
  4. Where a comparison is needed between the performance of a fixing listed and a known requirement, we suggest a Safety Factor of 4 be applied.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Germany

Material

Autoclaved aerated concrete (AAC)

Recyclability

At end of life

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

2

IFC
-

2

Third party certifications

EPD

EPD

Celcon Vertical Wall Panels EPD

NHBC ACCEPTS Third Party

NHBC ACCEPTS Third Party

NHBC Celcon Elements Certificate

Literature

H+H Vertical Wall Panel Brochure

H+H Vertical Wall Panel Brochure

H+H - Celcon Vertical Wall Panel Flyer

H+H - Celcon Vertical Wall Panel Flyer

H+H - Celcon Vertical Wall Panel Typical Details

H+H - Celcon Vertical Wall Panel Typical Details

Case studies

I-House using Celcon Vertical Wall Panels

I-House using Celcon Vertical Wall Panels

Stanpit I-House, Karm Homes

Stanpit I-House, Karm Homes

Galion Ltd

Galion Ltd