A range of chain actuators, suitable for façade and roof windows.

Features and benefits:

  • Can be used for windows and vents for smoke exhaust; D+H Euro SHEV in accordance with EN 12101-2 and for daily ventilation.
  • With integrated BSY+ motor and synchronized electronics controlled via microprocessor.
  • High-speed function (HS) for especially fast opening windows in case of fire (SHEV).
  • Option of up to 2 twin drives in one synchronous group.
  • Relief of pressure on window gasket after closing process.
  • Symmetrical chain outlet for easy installation.
  • Programmable drive functions and different drive parameters.
  • Running speed in closed direction decreases to 5 mm/s (passive closing edge protection).
  • Time-controlled reversing when an obstacle is detected in the closed direction (active closing edge protection).

General information
Specification data
Product Reference

CDP Chain Actuator

Type

See 'Options' below and insert reference.

Accessories

None

Brackets

Various options available consult literature and insert product reference(s).

Cables

Standard product features

Technical characteristics:

  • Supply: 24 V d.c (5 A). Except for '- K' drives which requires 230 V (50 Hz).
  • Duty cycle: 30 %.
  • Force of pressure: 1500 or 3000 N. (Twin drives).
  • Tensile force: 1000 or 2000 N. (Twin drives).
  • Nominal locking force: 1500 or 3000 N. (Twin drives).
  • Service life: > 10 000 double strokes.
  • Open running speed: 6 mm/s.
  • Open running speed - SHEV: 17.7 mm/s.
  • Closed running speed: 6 mm/s.
  • Ingress protection rating: IP 32.
  • Fire resistance: B300 (30 min/ 300°C).
  • Housing: Aluminium.
  • Surface: Powder coated silver (~RAL 9006).
  • Connection: 2.5 m cable.
  • Standards: EN 12101-2 CE certified and VdS G 513003.

Product Options

Type:

  • CDP 1500-BSY+ drive (24 V d.c).
  • CDP 1500-K-BSY+ drive (direct control via 230 V).
  • CDP TW 3000-BSY+ drive (24 V d.c).
  • CDP TW 3000-K-BSY+ drive (direct control via 230 V).
  • CDP 1500/600-BSY+ - Stroke: 600 mm.
  • CDP 1500/800-BSY+ - Stroke: 800 mm.
  • CDP 1500/1000-BSY+ - Stroke: 1000 mm.
  • CDP 1500/1200-BSY+ - Stroke: 1200 mm.
  • CDP 1500/1500-BSY+ - Stroke: 1500 mm.
  • CDP-BSY+ - Bespoke, variable equipment possible.
  • CDP 1500/600-K-BSY+ - Stroke: 600 mm.
  • CDP 1500/800-K-BSY+ - Stroke: 800 mm.
  • CDP 1500/1000-K-BSY+ - Stroke: 1000 mm.
  • CDP 1500/1200-K-BSY+ - Stroke: 1200 mm.
  • CDP 1500/1500-K-BSY+ - Stroke: 1500 mm.
  • CDP-K-BSY+ - Bespoke, variable equipment possible.
  • CDP-TW 3000/600-BSY+ - Stroke: 600 mm.
  • CDP-TW 3000/800-BSY+ - Stroke: 800 mm.
  • CDP-TW 3000/1000-BSY+ - Stroke: 1000 mm.
  • CDP-TW 3000/1200-BSY+ - Stroke: 1200 mm.
  • CDP-TW 3000/1500-BSY+ - Stroke: 1500 mm.
  • CDP-TW-BSY + - Bespoke, variable equipment possible.
  • CDP-TW 3000/600-K-BSY+ - Stroke: 600 mm.
  • CDP-TW 3000/800-K-BSY+ - Stroke: 800 mm.
  • CDP-TW 3000/1000-K-BSY+ - Stroke: 1000 mm.
  • CDP-TW 3000/1200-K-BSY+ - Stroke: 1200 mm.
  • CDP-TW 3000/1500-K-BSY+ - Stroke: 1500 mm.
  • CDP-TW-K-BSY+ - Bespoke, variable equipment possible.