Verified by manufacturer 3 months ago
Catnic Single Leaf Angle Lintel Standard Duty – ANG0900
BBA Agrément Certificate
Certificate type
EPD
Certificate type
Single leaf wall lintels.
Safe working load (SWL) and weight are dependent on lintel's length.
Color | Silver Black |
Finish | Galvanized Powder-coated |
Material | Steel |
Shape | Other |
Length | Bespoke |
Width | 91 mm 88 mm |
Height | 88 mm 131 mm 167 mm 215 mm 213 mm |
Uniclass | |
CAWS | F30/85 Prefabricated steel lintels F30/755 Prefabricated steel lintels |
Standard | To EN 845-2. |
Lintel type | Single. |
Material finish and coating reference | Galvanized.Powder coated. |
Sizes | Manufacturer guidance
|
Characteristics | |
Deflection under load | Dependent on length specified.Guidance for specification option: Deflection is proportional to the product length. Calculated as follows: (length as specified - 150)/325. Example values - length of 4800 or 1200 mm: (4800-150)/325 = 14.3 mm. (1200-150)/325 = 3.2 mm. |
Mass | 2.7 kg/m. |
Resistance to fire | Non-combustible. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Steel |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 15.2 kg CO₂ eq/unit Manufacturer guidanceRefer to EPD. |
Recyclability | 96% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 17 % |
Expected Life | 60 year |
Catnic Cavity Wall Lintel - Extra Heavy Duty - Lintel
Catnic Cavity Wall Lintel - Heavy Duty
Catnic Cavity Wall Lintel - Standard Duty
Catnic External Solid Wall Lintel
Catnic Internal Solid Wall Lintel
Catnic Internal Wall Box Lintel
Catnic Single Leaf Channel Lintel – Standard Duty
Catnic Thermally Broken Lintel - Extra Heavy Duty
Catnic Thermally Broken Lintel - Heavy Duty