Verified by manufacturer 2 months ago
Structural glazed - firerated glazing
Structural glass rooflights and structures with a clear frameless appearance.
Rooflights, Walls, Facades, Floors.
Structural glass rooflights and structures with a clear frameless appearance.
Features and benefits:
Color | Clear Guidance for specification option: Glass. Other Guidance for specification option: Framing. |
Material | Glass Aluminium |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Uniclass | |
CAWS | L10/460 Rooflights L10/45 Rooflights |
Form | Fire-rated glazing. |
Size | Guidance for specification option: Insert requirements. Unsupported spans up to 6 m. |
Product performance | |
Whole window U-value | To BS EN 10077, 1.4 W/m²K (maximum). |
Frame | |
Material | Aluminium.Manufacturer guidanceA combination of thermally broken aluminium profile with fully cleated corners and steel profiles depending on the dimensions. Fully assembled and thermally isolated with Nylon and XPS insulation. |
Finish | |
Coating | Powder coating. |
Colour | Guidance for specification option: Insert requirements; powder coated in any standard RAL colour. |
Film thickness (minimum) | Manufacturer's standard. |
Glazing or infill | |
Type | Toughened safety glass.Heat-strengthened laminate safety glass.Other.Guidance for specification option: Consult manufacturer for alternatives and insert requirements. Options include low iron glass, along with acoustic or security interlayers. See Coatings for further options. |
Construction | Double glazed, standard.Double glazed, low iron glass.Double glazed with acoustic interlayers.Double glazed with security interlayers. |
Colour | Clear. |
Coating | Low-E to achieve minimum centre pane U-value of 1.1 W/m²K.Guidance for specification option: Standard. Solar control to achieve minimum centre pane U-value of 1.0 W/m²K.None. |
Operation | |
Type | Not applicable. |
Control | Not applicable.Guidance for specification option: Standard, belt-driven by synchronised electronic motors controlled through central Printed Circuit Board (pcb). The whole 24 V system is designed to be 'plug and play'. Manufacturer guidanceAn uninterrupted power supply (UPS) is achieved by installing a battery backup to allow for operation even during power outage. |
Air permeability | To BS EN 12207, 'Wet sealed'. |
Resistance to wind load | To BS EN 12210, 'Wet sealed'. |
Watertightness | To BS EN 12208, 'Wet sealed'. |
Performance characteristics | CWCT classification (TN92) horizontal: Class 2 (if four-edge supported and panels <4.5 m²). |
Material | Glass Aluminium |