Verified by manufacturer 1 month ago
BST Special Line
Curved sliding doors providing customized entrance areas.
Suitable for entrance areas.
Curved sliding doors manufactured to order as concave and convex versions, and used in half circle, full circle, oval and segmental configurations.
FBST Special Line automatic curved sliding doors can be supplied with a redundant operator, an additional control unit for safety purposes, and a special radar motion detector for use on emergency exits and escape routes.
Color | Silver Other |
Finish | Smooth Guidance for specification option: Glass. Brushed Guidance for specification option: Stainless steel. Polished Guidance for specification option: Stainless steel. Anodized Coated |
Material | Glass Stainless steel |
Shape | Circle Crescent Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/490 Automatic doors |
Product range |
Performance | External. |
Arrangement | Bi-parting opening.Manufacturer guidanceSee also Configuration and Sliding panels for related options. |
Track system | Manufacturer's standard.Manufacturer guidanceSee below for further related options. |
Door leaves | |
Construction | Fine-frame profile system with 10 mm laminated safety glass.Guidance for specification option: Standard. Insulating glass profile system with 18 mm insulating glass.Other.Guidance for specification option: Special glazing; consult manufacturer for details and recommendations, and insert requirements. Options include patterning, sand-blast effect, screen printing etc. |
Finish and colour | Guidance for specification option: Consult manufacture for options and insert requirements. |
Operation | Powered. |
Hardware | Not applicable.Electromechanical lock.Electromechanical lock with manual unlocking. |
Accessories | None.Air curtain.Guidance for specification option: 180° and 360° design; canopy extension required. Ceiling aperture for downlights.Guidance for specification option: Downlights by others. Curved fanlight.Electro-mechanical locking device with mechanical lock release.Electro-mechanical locking device.Emergency Off pushbutton.Fail-safe via emergency power supply unit.Floor guide rail, flush-mounted, with floor ring.Guidance for specification option: Compulsory for clear passage widths > 1500 mm. Floor guide rail, surface-mounted, with floor ring.Floor guide rail, surface-mounted, without floor ring.Floor mat, Arwei.Floor mat, Emco.Halogen spot, 20 W, including ceiling aperture and accessories.Lateral facade connection glass/ panel board.Midrails, adhesive bonded.Monitored rechargeable battery pack.Program switch.Guidance for specification option: Consult DORMA for options and recommendations. Radar motion detector, external.Radar motion detector, internal.Straight panel board for top facade connection. |
Standard | To BS EN 16005. |
Configuration | Half circle, concave. Guidance for specification option: 180°; one set of symmetrical doors. Half circle, convex. Guidance for specification option: 180°; one set of symmetrical doors. Full circle, symmetrical. Guidance for specification option: 360°; two sets of doors. Full circle, asymmetrical facade connection. Guidance for specification option: 360°; two sets of doors. Full circle, three integrated entrance areas. Guidance for specification option: 360°; one set of bi-parting doors + two single doors. Manufacturer guidanceSee also Sliding panels for related options. |
Radius | Guidance for specification option: Insert requirements:
Manufacturer guidanceOther dimensions available on request, consult manufacturer for details. |
Sliding panels | One panel, concave. One panel, convex. Two panel, concave. Two panel, convex. |
Clear passage width | Guidance for specification option: Insert requirements. 1000–2500 mm; maximum 1300 mm for one-panel door. |
Passage height | Manufacturer guidanceInsert requirements. 2100–2500 mm. |
Canopy height | Guidance for specification option: Insert requirements, minimum 240 mm. |
Canopy height extension | Guidance for specification option: Optional; omit if not required, or insert requirements (240–700 mm). |
Ceiling | Operator cover. Guidance for specification option: Upper dust-proof ceiling supplied as standard for segmental configurations. Rain-proof ceiling with drainage spouts. Guidance for specification option: Not available for segmental configurations. Other. Guidance for specification option: Consult manufacturer for other options and insert requirements. |
Fixed side screens | Guidance for specification option: Consult manufacturer for details and insert requirements, or omit. |
Power supply | Voltage/ frequency: 230 V/ 50–60 Hz. |
Power consumption | Maximum: 250 W. |
Activation and control system | Microprocessor control unit; self-learning, self-testing. |
Operator | ES 200. |
Speed | Opening: 100–600 mm/s per panel. Guidance for specification option: All parameters are adjustable. |
Force | Adjustable opening and closing force. |
Safety features | Obstruction self-recognition; automatic reversing cycle on obstruction contact. |
Material | Glass Stainless steel |
Platform | Compatible | Version |
---|---|---|
- | 1 |