Verified by manufacturer over a year ago
A high-quality virgin PVC wall cladding system for any hygienic environment, fitted with manufacturers trims that can be both welded and thermoformed.
Suitable use for walls in commercial kitchens, educational facilities, hospitals and leisure.
A high-quality virgin PVC wall cladding system for any hygienic environment, fitted with manufacturers trims that can be both welded and thermoformed.
Suitable substrates:
Color | White Blue Grey Green Cream |
Finish | Satin |
Material | Polyvinyl chloride (PVC) Solid PVC sheet. |
Shape | Rectangle |
Length | 2440 mm 2800 mm 3050 mm |
Width | 1220 mm |
Height | 2.5 mm |
WarrantyDescription | 20 year |
Uniclass | |
CAWS | K13/145 Proprietary plastics cladding K13/145 Proprietary plastics cladding |
Material | Antimicrobial PVC sheet. |
Fire performance | BS 476 Class 1 (Class 0 when bonded to non-combustible substrate). |
Thickness | 2.5 mm. |
Sheet size | 1220 x 2440 mm.1220 x 2800 mm.1220 x 3050 mm. |
Finish | Satin. |
Colour | Satin white.Blue.Grey.Green.Cream.Sandbank. |
Edges | PVC trimmed. |
Execution | Cutting. Fine toothed blade jigsaw or circular saw with fine TCT sawblade whilst sheet is supported. Joints. Sheets can be sealed by hot welding providing a water-tight finish or joined with matching PVC single and 2-part silicon free trim systems. Between sheet and floor. Sheets can be overlaid or trim fixed to a vinyl flooring system. Tile and resin flooring trims also available. |
Accessories | PVC division bar (H-trim) two-part. Welded joint detail. PVC edge trim (J-trim). Thermoformed corners. Vinyl floor two-part joint detail. |
Chemical resistance | Advanced PVC® is resistant to a wide range of chemicals found within the medical, healthcare and food production industries. Full chemical resistance data report available on request. |
Maximum temperature | 60°C. Sheets can NOT be used near naked flame. Full technical information and consultation available from manufacturer. |
NBS BIM object standard
This BIM object has been authored to meet the requirements of the NBS BIM object standard.
Find out more about the NBS BIM object standard.
Platform | Compatible | Version |
---|---|---|
![]() | - | 1 |
![]() | - | 1 |
![]() | Revit 2016 | 5 |
![]() | - | 1 |
![]() | IFC2X3 | 4 |