Verified by manufacturer 3 months ago
Board edge infills
Suspended ceiling system with lay-in mineral ceiling tiles combining excellent cleanability, resistance to disinfectants, sound absorption and antimicrobial performance.
Suitable for healthcare environments with average to severe risk of infection.
Biobloc Acoustic combines excellent cleanability, resistance to disinfectants and sound absorption. Along with its antimicrobial performance makes it a good solution for healthcare environments.
Features and benefits:
Tiles:
Grids:
Color | White |
Finish | Mineral |
Material | Mineral fibre Steel |
Shape | Square Rectangle Other |
Length | Bespoke |
Width | Bespoke |
Height | 17 mm |
Warranty description | 30 year Guidance for specification option: System guarantee. |
Uniclass | |
CAWS | K40/10 Unit/ modular suspended ceilings K40/105 Suspended ceiling system K40/115 Unit/ modular suspended ceiling system |
System performance | Guidance for specification option: Insert requirements. |
Ceiling support | Gridline 24 joggled /butt cut, Global White.Guidance for specification option: Gridline 24 Cross Tees are designed to work with Gridline 24, a 24 mm exposed grid system for suspended ceilings. These cross tees come with standard SureLock clip for secure connections to main runners, providing better alignment for easier ceiling installation and easy disconnection when access to the ceiling soffit is required. Baked polyester paint finish. Gridline 24 joggled /butt cut, Black.Guidance for specification option: Gridline 24 Cross Tees are designed to work with Gridline 24, a 24 mm exposed grid system for suspended ceilings. These cross tees come with standard SureLock clip for secure connections to main runners, providing better alignment for easier ceiling installation and easy disconnection when access to the ceiling soffit is required. Baked polyester paint finish. Gridline 24 Corrosive Resistant, Global White.Guidance for specification option: Consult manufacturer for options and insert requirements. Corrosive Resistant TL+ Cross Tees are finished with a special corrosion resistant paint for better performance in high humidity environments - recommended when system is to be installed in areas >90% relative humidity. These cross tees are Durability Class C (EN 13964:2004 + A1:2006) and have completed a 700 hours salt spray test (EN ISO 9227). Clean Room 24, Global White.Guidance for specification option: Exposed 24 mm co-extruded grid system for clean rooms and non-magnetic areas. They can be used in clean rooms with ISO 4 classification in accordance with ISO 14644-1:1999. |
Support fasteners | Guidance for specification option: Insert requirements to suit substrate. |
Ceiling units | 600 x 600 x 17 mm, Global White, unpainted board edges (2549M).1200 x 600 x 17 mm, Global White, unpainted board edges (2550M).Manufacturer guidance
|
Barriers in ceiling void | |
Fire barriers | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Acoustic barriers | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Plenum barriers | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
System accessories | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Weight | Infill units: 4.5 kg/m². |
Reaction to fire | To EN 13501-1, infill units: Euroclass A2-s1, d0 (limited combustibility); support grid: Euroclass A1. |
Sound attenuation | Infill units: Dnfw = 35 dB. |
Sound absorption | Infill units: αw = 0.60(H); Class C. Manufacturer guidanceWeighted sound absorption coefficient (alpha w). Rating for random incidence sound absorption determined in accordance with BS EN ISO 11654. Measured values obtained in accordance with BS EN ISO 20354 are converted into octave bands, plotted on a graph and compared to a standard reference curve until a 'best fit' is obtained. The derived αw will vary between 0.00 and 1.00. |
Weighted sound reduction index, Rw | Infill units: 18 dB. |
Noise reduction coefficient | Infill units: 0.65. |
VOC emissions | The VOC emission performance in accordance with the French labelling requirements: A+. |
Formaldehyde emissions | Infill units: Formaldehyde emission level E1 = Best test result possible. |
Colour (Light reflectance value (LRV) | Infill units: 85%. |
Cleanroom classification | To ISO 14644-1, ISO 4. |
RelativeHumidity | Infill units: 95%. |
Country of product manufacture | United Kingdom |
Material | Mineral fibre Steel |
Recyclability | Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 42 % Guidance for specification option: Infill units only. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 3 | |
- | 3 |