Features and benefits:
Color | Black Guidance for specification option: RAL9005. Grey Guidance for specification option: Light Grey (BS00A09), Dark Grey (BS00A13). White Guidance for specification option: RAL9010. Other Guidance for specification option: As per manufacturer and includes BS, all standard RAL colours and other special colours to match roof covering available on request. |
Finish | Powder-coated |
Material | Glass Steel |
Shape | Other Guidance for specification option: Polysided or design solutions to suit specific size and shape requirements. Rectangle Square Triangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Guidance for specification option: Rooflights must be registered online to receive the full warranty. One year Guidance for specification option: On ancillary items. Five year Guidance for specification option: On glass. Ten year Guidance for specification option: On frames upon the rooflights being registered for free, online via the manufacturer website. |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
Form | Flat. Pitched. |
Size | As drawing. |
Product performance | |
Whole window U-value | 1.4 W/m²K. Guidance for specification option: Based on our standard specifications. Whole unit U-values will vary depending on specification and design. U-values as low as 1.0 W/m²K can be achieved. |
Frame | |
Material | Carbon steel. Stainless steel. Guidance for specification option: Different material specifications (e.g. stainless steel) are available for applications in industrial or maritime locations. Consult manufacturer for details. |
Finish | |
Coating | Polyester powder coating. |
Colour | Black (RAL 9005). Dark Grey (BS 00A13). Light Grey (BS 00A09). White (RAL 9010). Any BS. Guidance for specification option: Insert requirements. Any RAL. Guidance for specification option: Insert requirements. As drawing. As schedule. |
Glazing or infill | |
Type | Insulating glass units. |
Construction | 4 mm SGG Planilux Toughened Outer, 16 mm 90% Argon Cavity, 4 mm SGG Planitherm One II (Low E) Toughened Inner. Guidance for specification option: Achieving a glass centre pane U-value of 1.0 W/m²K. Manufacturer guidanceEnhanced glazing specification incorporating thermal, acoustic, security, light transmission, passive solar gain and decorative options are available. |
Colour | Clear. Opal. Bronze tint. Grey tint. Diffused. |
Coating | Low emissivity. Solar control. UV protection. Self-cleaning. |
Integral kerb | Insulated kerb to be formed on site. |
Operation | |
Type | Electric openings. Electric chain actuator. Electric linear actuator. Electric rack actuator. Hand winder. Manual openings (within reach). Manual openings (out of reach). Pole winder and winding crank. |
Control | Rain sensors. Link to BMS Remote control. Switch control. |
Accessories | Not required. Rain temperature and smoke sensors. Guidance for specification option: Available on request. An on/ off switch is required . Guidance for specification option: Consult manufacturer for details. |
Electric actuators | Guidance for specification option:
Manufacturer guidanceRain, temperature and smoke sensors are available on request. An on/ off switch is required. Consult manufacturer for details and insert requirements. |
Standard | To BS EN1279-2. |
Third-party certification | BSI Kitemark and KM 93754. |