Verified by manufacturer 4 months ago
Bespoke
EPD
Certificate type
Hygienic rigid PVC wall cladding system using rigid, solid, extruded PVC-U in a range of thicknesses, sizes, finishes and colours to create hygienic environments.
PVC Hygienic Wall Cladding used for:
Elite Komadur has the world’s most comprehensive range of sizes and thicknesses for PVC hygienic wall cladding. Complete with a full range of accessories to create the perfect solution. Joints can be welded where necessary.
Utilizing a range of ancillaries and adhesives to meet all UK, EU and global hygiene, fire and building regulations. Elite Komadur offers a cost effective, versatile hygienic wall covering for a wide variety of environments.
Features and benefits:
Color | White Cream Grey Black Blue |
Finish | Satin Guidance for specification option: With protective film. |
Material | Polyvinyl chloride (PVC) |
Shape | Rectangle |
Length | 2440 mm 2750 mm 3050 mm 2220 mm 3660 mm |
Width | 1220 mm |
Height | 2.5 mm 2 mm |
Warranty description | 30 year |
Uniclass | |
CAWS | K13/145 Proprietary plastics cladding K13/145 Proprietary plastics cladding |
Material | Solid PVC sheet. |
Thickness | 2.5 mm. |
Edges | Two-part flex edge joint detail, 2440 x 2.5 mm.Two-part flex edge joint detail, 3050 x 2.5 mm.One-part rigid edge joint detail, 2440 x 2.5 mm.One-part rigid edge joint detail, 3050 x 2.5 mm.One-part rigid edge joint detail, 2440 x 3.0 mm.One-part rigid edge joint detail, 3050 x 3.0 mm.PVC capping section(s), 2440 x 3 mm.Guidance for specification option: High-impact; for exposed panel edges. PVC capping section(s), 3050 x 3 mm.Guidance for specification option: High-impact; for exposed panel edges. Not required.Manufacturer guidanceApply Be-Plas food-grade silicone sealant (Ref. PSNW) in mouldings and around all panel edges, fasteners and fixtures. |
Fire performance | To BS 476-7, Class 1; Class 0 when attached to a non-combustible substrate.Manufacturer guidanceTo BS 476-6, class 0 when adhered to a non-combustible substrate. |
Fixing | Be-Plas adhesive. Guidance for specification option: Available in 6.5 or 8 kg. Consult manufacturer for further details. GPPA600 adhesive. Guidance for specification option: Consult manufacturer for details. Multibead. Guidance for specification option: Consult manufacturer for details. PRO6.5. PRO8. |
Accessories | None. Guidance for specification option: An extensive range of accessories including corner and joint details are available, consult manufacturer and insert requirements. Internal corner detail, 2440 x 25 x 25 mm. Internal corner detail, 3050 x 25 x 25 mm. Internal corner detail, 2440 x 38 x 38 mm. Internal corner detail, 3050 x 38 x 38 mm. |
OperationalTemperatureRange | -10°C to +60°C. |
Apparent density | ~1.43 g/cm³. Guidance for specification option: To DIN 53479/ ISO 1183. |
TensileStrength | ≥55 MPa. Guidance for specification option: To DIN 53455/ ISO 527. |
Elongation at break | ≥15%. |
Flexural strength | ≥80 MPa. Guidance for specification option: To DIN 53452/ ISO 178. |
CompressiveStrength | ≥70 MPa. Guidance for specification option: To DIN 53454/ ISO 3605. |
Modulus of elasticity | ≥3000 MPa. Guidance for specification option: To DIN 53457/ ISO 527-2/1A/50. |
Hardness | ~100 MPa. Guidance for specification option: Ball indentation hardness (358 N/30 s) to DIN 53456/ ISO 2039. |
Shore Hardness - D | 82. Guidance for specification option: To DIN 53505. |
Vicat softening temperature | ≥75°C. Guidance for specification option: To DIN 53460/ ISO 306 (process B50). |
Deflection | ~68°C. Guidance for specification option: To DIN 53461/ ISO 75. |
Co-efficient of linear thermal expansion | 0.08 mm/m·K. Guidance for specification option: From –30 °C to +50 °C (process Ae) to DIN 53752. |
ThermalConductivity | 0.16 W/m·K. Guidance for specification option: 0 °C to +60 °C to DIN 52612. |
Water absorption | <0.08%. Guidance for specification option: After 7 days to DIN 53495. |
Strength | ≥4 kJ/m²: Guidance for specification option: Notched impact strength to DIN 53453/ ISO 179-1ePA. |
Electric resistance | 10^10 Ω. Guidance for specification option: Surface resistance. |
Electrical resistance | T5, 2.2.2.2. Guidance for specification option: Electrical arc resistance to DIN VDE 0303. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | Germany |
Material | Polyvinyl chloride (PVC) |
Manufacturing plant location | |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 3.16 kg CO₂ eq/m² |
Recyclability | 100 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 6 % |
Expected Life | 25 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Beplas Elite Komadur 2.5mm/ Endurance/ FRP to resin floor detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP to shower tray detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP to shower tray with trim detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP to Tile Floor
Beplas Elite Komadur 2.5mm/ Endurance/ FRP with vertical joint strip and corner trims detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP with vertical joint strip and thermoformed corner detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP with vinyl floor trim detail drawing
Beplas Elite Komadur 2.5mm/ Endurance/ FRP with Vinyl Overlap
Beplas Elite Komadur and FRP installation guide
Beplas Elite Komadur Chemical Resistance
Beplas Elite Komadur Cleaning Instructions
Beplas Elite Komadur Specification
Elite Komadur Technical Data
Elite Komadur Product Leaflet